RTD Sensors Fast Response Exposed RTD Element with ACCURACY Fiberglass Insulated Lead Wires IEC CLASS A (0.15C 0C) RTD-2-1PT100KN2528-36-G shown actual size. U Thermal Response (63%) Less Than 1 Second U Operating Ranges: -30 to 300C (-22 to 572F) Class A Thin Film Element Styles, -100 to 450C (-148 to 842F) Class A Wire Wound Element Styles U 1 m (40 ) Long 2-, 3-, or 4-Wire 26 AWG Stranded Nickel Plated Copper, Fiberglass Insulated and Jacketed Cable Constructions Available U Ceramic Cement Insulating Element to Cable Connection To Order Resistance at 0 Model No. and Accuracy Element Size Element Type RTD-2-F3105-36-G 100 0.06 , Class A 2 W x 2 mm L Thin film RTD-2-F3102-36-G 100 0.06 , Class A 4 W x 5 mm L Thin film RTD-2-1PT100KN2515-36-G 100 0.06 , Class A 1.5 Dia. x 25 mm L Wire wound RTD-2-1PT100KN2528-36-G 100 0.06 , Class A 2.8 Dia. x 25 mm L Wire wound RTD-2-F3145-36-G 1000 0.60 , Class A 2 W x 2 mm L Thin film RTD-2-F3142-36-G 1000 0.60 , Class B 4 W x 5 mm L Thin film For 2-wire, replace 2 in model number with 1 and subtract cost from price. For 4-wire assembly, replace 2 in model number with 3 and add cost to price. For longer leads, change -36 in model number to length in inches and add cost for 3- and 4-wire cables or 2-wire cables to the price. For spade style terminal lugs standard termination in stripped leads, add -LUG to the model number for additional cost. For connectors (3-wire only) add -OTP to the model number for full sized connector or -MTP for miniature connector for additional cost. Ordering Examples: RTD-3-F3105-36-G, 100 , 2 x 2 mm, thin film Pt100 RTD element, Class A accuracy with 4-wire fiberglass insulated cable 1 m (40 ) long with ceramic cement over connection and stripped leads. RTD-2-1PT100KN2515-36-G-MTP, 100 , 1.5 Dia. x 25 long mm, Pt100 wire wound element, Class A accuracy with 3-wire fiberglass insulated cable 1 m (40 ) long with ceramic cement over connection and miniature 3-pin connector. Popular Options Include: HH804U, handheld meter. OM-DAQPRO-5300 handheld OMEGABOND data logger. high temp chemical 1 DP25B-RTD 8 DIN panel meter. set cements. 109RTD Sensors Fast Response ACCURACY Exposed RTD Element C IEC CLASS A (0.15C 0C) with PFA Lead Wires Enlarged tip view. U Thermal Response (63%) Less Than 1 Second U High Accuracy Class A, Pt100 and Pt1000 RTD Elements Standard 1 1 U Higher Accuracy 3 and 10 DIN Elements Are Available in Some Styles* U Operating Range: -30 to 260C (-22 to 500F) Class A Thin Film Element Styles, -100 to 260C (-148 to 500F) Class A Wire Wound Element Styles U 1 m (40 ) Long 2-, 3- or 4-Conductor 26 AWG Stranded Nickel Plated Copper, PFA Insulated and Jacketed Cable Constructions Available U Epoxy Potting Insulating Element to Cable Connection RTD-2-F3105-36-T 1 Note: Temperature range for 3 DIN is 0 to 150C (32 to 302F) * shown actual size. 1 and temperature range for 10 DIN is 0 to 100C (32 to 212F). 1 Also, note 4-wire configuration only for 10 DIN. To Order Resistance at 0 Model No. and Accuracy Element Size Element Type RTD-2-F3105-36-T 100 0.06 , Class A 2 W x 2 mm L Thin film RTD-2-F3102-36-T 100 0.06 , Class A 4 W x 5 mm L Thin film RTD-2-1PT100KN2515-36-T 100 0.06 , Class A 1.5 Dia. x 25 mm L Wire wound RTD-2-1PT100KN2528-36-T 100 0.06 , Class A 2.8 Dia. x 25 mm L Wire wound RTD-2-F3145-36-T 1000 0.60 , Class A 2 W x 2 mm L Thin film RTD-2-F3142-36-T 1000 0.60 , Class B 4 W x 5 mm L Thin film For 2-wire, replace 2 in model number with 1 and subtract cost from price. For 4-wire assembly, replace 2 in model number with 3 1 1 and add cost to price. For 3 DIN accuracy, add -1/3 to end of model number for additional cost. For 10 DIN accuracy, add -1/10 to the 1 model number for additional cost. (Note: 10 DIN option is only available in 4-wire construction). For longer leads, change -36 in model number to length in inches and add cost for 3- and 4-wire cables, or 2-wire cables,for an additional cost. For spade style terminal lugs standard termination in stripped leads, add -LUG to the model number for additional cost. For connectors (3-wire only) add -OTP to the model number for full sized connector, or -MTP for miniature connector for additional cost. 1 Ordering Examples: RTD-3-F3105-36-T-1/3, 100 , 2 x 2 mm, thin film Pt100 RTD element, 3 DIN accuracy with 4-wire PFA insulated cable 1 m (40 ) long with epoxy over connection and stripped leads. RTD-2-1PT100KN2515-36-T-MTP, 100 , 1.5 Dia. x 25 long mm, Pt100 wire wound element, Class A accuracy with 3-wire PFA insulated cable 1 m (40 ) long with epoxy over connection and miniature 3-pin connector. Popular Options Include: HE-XT105 PLC/HMI all-in-one. OM-SQ2010 data logger. CN1A temperature controller. 110