Small Enclosed Switches
VE
CSM_VE_DS_E_2_2
Small, Lightweight Enclosed
Switches
V-series Switches were placed in diecast cases to provide
superior dust resistance and mechanical strength.
Cam arms and cam roller arms can be set to any position
within 360
Be sure to read Safety Precautions on page 4 and Precautions for
All Limit Switches.
Model Number Legend
Model Number Structure (Some combinations may not be available. Contact your OMRON sales representative for details.)
@VE-10@-@-@
1234
1. Number of Built-in 3. Operation Direction 4. Bushing Type
Blank: Rubber bushing for single-core vinyl cables
Switches (for Arm Actuators Only)
C: Rubber bushing for vinyl cabtire cable
1: 1 Blank: Plunger
Note: For details, refer to Safety Precautions on page 4.
11: Counterclockwise operation
2. Actuator Type
(one-side operation)
N: Sealed plunger
12: Clockwise operation
CA: Cam arm
(one-side operation)
CA2: Cam roller arm
13: Operation in both directions
(two-side operation)
Ordering Information
One built-in switch
Actuator type Operating direction
Model
Sealed plunger
--- 1VE-10N
Counterclockwise
1VE-10CA-11
operation
Cam arm
Clockwise
1VE-10CA-12
operation
Two-side operation 1VE-10CA-13
Counterclockwise
1VE-10CA2-11
operation
Cam roller arm
Clockwise
1VE-10CA2-12
operation
Two-side operation 1VE-10CA2-13
1VE
Ratings and Specifications
Ratings
Non-inductive load (A) Inductive load (A) NC 24 A max.
Inrush
Rated
current
Resistive load Lamp load Inductive load Motor load NO 24 A max.
voltage (V)
NC NO NC NO NC NO NC NO
Note: 1. The above values are continuous
125 AC 10 2 10 3
currents.
250 10 1.5 10 2
2. Inductive loads have a power
factor of 0.4 or higher (AC) or a
8 DC 10 2 6 6
14 10 3 6 6 time constant of 7 ms or lower
30 6 3 4 4
(DC).
125 0.6 0.1 0.6 0.1
3. Lamp loads have an inrush
250 0.3 0.05 0.3 0.05
current of 10 times the steady-
state current.
4. Motor loads have an inrush
current of 6 times the steady-state
current.
Characteristics Engineering Data
Switch with Cam Roller Arm Electrical
Degree of protection IP60
Durability Graph
Mechanical 1,500,000 operations min.
Durability*
Operating frequency: 60 operations/min
Electrical 300,000 operations min. (10 A at 250 VAC, resistive load) 200
Operating angle: 60 degrees
cos = 1
Sealed plunger: 0.1 mm/s to 0.5 m/s
Operating speed Cam arm: 0.5 mm/s to 0.5 m/s
100
250 VAC
Cam roller arm: 0.5 mm/s to 0.5 m/s
70
Allowable Mechanical 120 operations/min.
50
operating
Electrical 60 operations/min.
frequency
30
Rated frequency 50/60 Hz
20
Insulation resistance 100 M min. (at 500 VDC)
10
Contact resistance 15 m max. (initial value)
Between terminals of
1,000 VAC at 50/60 Hz for 1 minute
the same polarity
Dielectric
Between each terminal
strength
0
24 6 8 10
and non-current- 1,500 VAC, 50/60 Hz for 1 minute
Switching current (A)
carrying parts
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
2 2
Shock resistance Destruction: 1,000 m/s max., Malfunction: 300 m/s max.
Ambient operating temperature 10C to 80C (with no icing)
Ambient operating humidity 35% to 95%
Weight Approx. 120 to 170 g
Note: The above values are initial values.
* The values are calculated at an operating temperature of 5C to 35C and an operating
humidity of 40% to 70%.
Contact your OMRON sales representative for more detailed information on other operating
environments.
Nomenclature
Structure Contact Form
Roller Built-in Switch (V)
COM NC
NO
Roller arm
Case
Cover
Conduit cap
2
4
Operations (x 10 )