Safety Interlock Switches T5009 & T5009-6 Universal Tongue-Operated Safety Interlock Switch Strong and versatilethe compact size of the strong, glass- filled polyester housing and metal reinforced cam allows this popular switch to be used in most applications NEMA 6 enclosure enables these switches to withstand water washdown cleaning. Rotatable head gives four possible actuator entry points for versa- tile installation. A blanking plug is supplied for the unused entry. Small swing radius allows use on doors with a swing radius as small as 2.5 in. when using the optional flexible actuators Hi-Hold models reduce nuisance rips and allow the switch to also serve as the gate catch without the need to mount any additional hardware. The 4 contact poles provide 2 poles for dual channel safety monitoring and 2 additional poles for status monitoring Optional connector makes installation easy An optional stainless steel head is available R A Rapid Delivery Product: Select models are available for ship- C US G ment today or within 3 to 5 days Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 UL and C-UL listed Specifications Electrical All Models T5009 T5009-6 Contact Configurations: 2 N/C + 1 N/O 2 N/C + 2 N/O, 3 N/C + 1 N/O, 4 N/C Safety Contacts: 2 N/C positive break Switching Ability AC: 500 V1 A, 240 V3 A, 120 V6 A DC: 250 V0.5 A, 24 V2.5 A Safety Contact Gap: > 2 mm (0.079 in.) Auxiliary Contacts: 1 N/O 1 N/C + 1 N/O, 2 N/C, 2 N/O Max Switching Current/Volt/Amp: 500 V/500 VA Minimum Current: 5 V 5 mA DC 6 Electrical Life: 1 x 10 minimum Mechanical Mounting: Any position Mounting Hardware: 2 x M5 screws Actuator Travel for Positive Opening: 7 mm (0.275 in.) Min Operating Radius: 60 mm (2.5 in.) with Flex 1 actuator 175 mm (6.89 in.) with standard actuator Break Contact Min Force: 12 N (2.7 lb.) Hi-Hold models are 50 N (11.2 lbs.) Max Actuation Speed: 160 mm/sec (6.30 in./sec) Max Actuation Frequency: 2 cycles/sec Case Material: UL listed, glass-filled polyester, optional stainless steel head Actuator Material: Stainless steel Wiring Entry: M20 with 1/2 in. NPT adapter included, 1/2 in. NPT, 6-pin micro AC connector 1/2 in. 20 Weight: 160 g (5.6 oz.) Color: Red 6 Mechanical Life: 1 x 10 minimum Environmental Protection: IP67 (NEMA 6) Operating Temperature: -25 to 80C (-13 to 176F) Cleaning: Water washdown Compliance Standards: EN1088, EN292, EN60947-5-1, EN60204-1, UL508 Approvals/Listings: CE marked for all applicable directives, UL and C-UL Specifications are subject to change without notice. Note: The safety contacts of the STI switches are described as normally closed (N/C) i.e., with the guard closed, actuator in place, and the machine able to be started. Select models are available for Rapid Delivery. Visit this product on www.sti.com for details.. www.sti.com/info G-186 HI-HOLD MODELS AVAILABLET5009 & T5009-6 Safety Interlock Switches Operation Removable terminal block for field service The head rotates 180 to give 4 possible actuator entry points. Blanking plug for unused entry. G Flex 1 Optional SLD Series Optional Connector 15 flexibility in for 3-Pole Switches Optional switch locking any direction. devices are available. See 6-Pin Male, Micro AC, 1/2-20 UN2A accessories section for details. Safety Circuit 1 (N/C) 1/2 UNF 11 12 1 5 Flex 2 6 15 flexibility in 2 4 3 two directions. 22 21 33 34 Safety Circuit 2 (N/C) Auxiliary Circuit (N/O) Contact Arrangements Minimum Allowable Radius for Actuator Entry 44501-0755 175 mm 175 mm 175 mm 175 mm 44501 -0785 175 mm 175 mm 175 mm 175 mm T5009-6 44501-0790 175 mm 175 mm 175 mm 175 mm 44501-0765 175 mm 50 mm 60 mm 175 mm 44501-0760 60 mm 60 mm 60 mm 60 mm T5009-6 Contact Block Operation at Withdrawl of Actuator 2N/C + 1 N/O Version 3N/C + 1N/O Version 4 N/C Version 2N/C + 2N/O version 7 7 7 7 0.28 0 0.28 0 0.28 0 0.28 0 11/12 11/12 11/12 11/12 21/22 21/22 21/22 21/22 33/34 31/32 31/32 33/34 41/42 41/42 43/44 7.8 7.8 7.8 0.31 0.31 0.31 Contact Open Contact Closed Contact Open Contact Closed Contact Open Contact Closed Contact Open Contact Closed www.sti.com/info G-187