Enabling Switch Devices A4EG Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions The difficult task of configuring safety circuits is now easily achieved by combining the A4EG with the G9SX-GS. In addition to the standard models, the lineup also includes models with an emergency stop switch and models with a momentary operation switch. An optional Holding Key (sold separately) provides a versatile method for selecting modes. Equipped with conduit connector. Specifications Standards and EC Directives Certified Standard Ratings (Enabling Switch Section) Compliance with EC Directives and International Standards Low Voltage Directive TV (EN 60947-5-1) GS-ET-22 Utilization category AC-15 DC-13 Certified Standards Rated operating current (Ie) 0.75 A 0.55 A Certifying body Standard File No. Rated operating voltage (Ue) 240 V 125 V EN 60947-5-1 Ask your Omron TV SD Note: Use a 10 A fuse type gI or gG that conforms to IEC 60269 as the (certified direct opening) representative. short-circuit protection device. The fuse is not built into the Switch UL * UL 508, CSA C22.2 No.14 E76675 CQC (CCC) GB 14048.5 Pending approval UL/CSA (UL 508, CSA C22.2 No.14), CCC (GB 14048.5) 24 VDC, 0.3 A (inductive load) Certification for CSA C22.2 No. 14 by UL is indicated by the registration 125 VAC, 1 A (resistive load) mark. Ratings Emergency stop switch Pushbutton Enabling switch (A4EG-BE2R041 only) (A4EG-BM2B041 only) Rated insulation voltage 250 V --- Rated ON current 2.5 A 5 A 0.1 A General rating: 125 VAC, 5 A (resistive load) General rating: 250 VAC, 3 A (resistive load) 125 VAC, 0.1 A (resistive load) 30 VDC, 3 A (resistive load) 8 VDC, 0.1 A (resistive load) 14 VDC, 0.1 A (resistive load) 24 VDC, 0.3 A (inductive load) UL and cUL rating: 30 VDC, 0.1 A (resistive load) 125 VAC, 1 A (resistive load) 125 VAC, 5 A Rated load (inductive load, power factor: 0.75 to 0.8) UL and cUL rating: EN certification rating: 250 VAC, 3 A 125 VAC, 0.1 A (resistive load) AC-15 0.75 A/240 V (inductive load, power factor: 0.75 to 0.8) 30 VDC, 0.1 A (resistive load) DC-13 0.55 A/125 V 30 VDC, 3 A (resistive load) EN certification rating: EN certification rating: AC-12 0.1 A/125 V AC-12 3 A/250 V DC-12 0.1 A/30 V DC-12 3 A/30 V Minimum applicable load 24 VDC, 4 mA 5 VDC, 1 mA M-61A4EG Enabling Switch Devices Specifications Characteristics Emergency Stop Switch Pushbutton Enabling Switch (A4EG-BE2R041 only) (A4EG-BM2B041 only) Degree of Protection: IP66 IP65 IP65 Operating Section Strength: Operating direction: 200 N, 1 min. Operating direction: 367 N, 1 min. Operating direction: 50 N, 1 min. Rotating direction: 0.49 N-m, 1 min. Cable Pull Strength: 30 N, 1 min. 30 N, 1 min. 30 N, 1 min. Allowable Operating Frequency Electrical: 20 operations/min. max. 10 operations/min. max. 60 operations/min. max. (set/reset for one operation) Mechanical: 20 operations/min. max. 10 operations/min. max. 120 operations/min. max. (set/reset for one operation) Electrical Durability (rated load): 100,000 operations min. 100,000 operations min. 100,000 operations min. (set/reset for one operation) Mechanical Durability: OFF-ON-OFF (direct opening): 100,000 operations min. 2,000,000 operations min. 100,000 operations min. (set/reset for one operation) OFF-ON: 1,000,000 operations min. Dielectric Strength: Between terminals of the same polarity 2,500 VAC, 50/60 Hz, 1 min. 1,000 VAC, 50/60 Hz, 1 min. 1,000 VAC, 50/60 Hz, 1 min. (impulse voltage) Between terminals of different polarities 2,500 VAC, 50/60 Hz, 1 min. 2,000 VAC, 50/60 Hz, 1 min. 2,000 VAC, 50/60 Hz, 1 min. (impulse voltage) Between each terminal and non-current 2,500 VAC, 50/60 Hz, 1 min. 2,000 VAC, 50/60 Hz, 1 min. 2,000 VAC, 50/60 Hz, 1 min. carrying metallic parts (impulse voltage) Insulation Resistance: 100 M min. (at 500 VDC) Vibration Resistance: Malfunction: 1.5 mm double amplitude, 10 to 55 Hz Shock Resistance: Malfunction: 150 m/s max. Ambient Operating Temperature: -10 to 55C (with no icing or condensation) Ambient Operating Humidity: 35% to 85% Ambient Storage Temperature: -25 to 65C (with no icing or condensation) Protection Against Electric Shock: Class II (double insulation) Pollution Degree (Operating 3 (EN 60947-5-1) Environment): Conditional Short-Circuit Current: 100 A (EN 60947-5-1) Note: The timing of contact outputs for two or more circuits is not synchronized. Confirm performance before application. Specifications are subject to change without notice. 2M-7