CompleteAssemblies Specifications Common to All A22/M22 The Following Pages Provide Information Common To Each Model of The A22/M22 Pushbutton Switch H A22 H A22S/W H A22K H M22 Specifications J APPROVEDSTANDARDS Recognized organization Standards File No. UL, cUL (See note) UL508 E41515 ASTA EN60947-5-1 Note: UL: CSA C22 No. 14 J RATINGS Contacts(General-purposeLoad) Rated carryy Rated Rated current (A) current volltage Utilization category AC15 (inductive load) AC12 (resistive load) DC13 (inductive load) DC12 (resistive load) 10 ampsp 24 VAC 10 10 110 VAC 5 10 220 VAC 3 6 380 VAC 2 3 440 VAC 1 2 24 VDC 1.5 10 110 VDC 0.5 2 220 VDC 0.2 0.6 380 VDC 0.1 0.2 Note: 1. Rated current values are determined according to the testing conditions specified by JIS C4520. The above ratings were obtained by conducting tests under the following conditions as specified by JIS C4505. (1) Ambient temperature: 202C (2) Ambient humidity: 655% (3) Operating frequency: 20 operations/min 2. Minimum applied load: 10 mA, 5 VDC Contacts(Microload) Rated applied load Minimum applied load 50 mA, 5 VDC (Resistive load) 1mA,5VDC LEDIndicatorswithoutTransformer Rated voltage Rated current Operating voltage 6VDC 60 mA 6VDC5% 6VAC 60 mA 6VAC/DC5% 12 VAC/DC 30 mA 12 VAC/DC5% 24 VAC/DC 15 mA 24 VAC/DC5% 30AllA22/M22Assemblies AllA22/M22Assemblies IncandescentLamp Rated voltage Rated current Operating voltage 6VDC 200 mA 5V 14 VAC/DC 80 mA 12 V 28 VAC/DC 40 mA 24 V 130 VAC/DC 20 mA 100 V TransformerLighting Rated voltage Operational voltage Applicable lamp (BA8S/13j gold) 110 VAC 95 to 115 VAC LED Lama pp ((A22-24Ajj)) 220 VAC 190 to 230 VAC J CHARACTERISTICS Item Pushbutton switches Emergency stop switches Knob-type selector switches Key-type selector switch Non-illuminated Illuminated Non-illuminated Illuminated Non-illuminated Illuminated Non-illuminated models: models: models: A22E models: models: A22S models: models: A22K A22-F, A22-T, A22L-T, A22EL A22W A22-G, A22L-G, A22-S, A22-C, A22L-H, A22-D, A22L-D, A22-H, A22-M A22L-C Allowable Mechanical Momentary operation: 30 operations/min max. Manual release: 30 operations/min max. ooperatperatiinngg 60 operations/min max. Automatic release: 30 operations/min max. ffrequency Electrical 30 operations/min max. 30 operations/min max. Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min between terminals of same polarity 2,500 VAC, 50/60 Hz for 1 min between terminals of different polarity and also between each terminal and ground Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms) (See note 2) 2 2 2 2 2 2 Shock Mechanical 1,000 m/s 1,000 m/s 1,000 m/s 100G 1,000 m/s 1,000 m/s 1,000 m/s rreesisistastannccee 100G 100G 100G 100G 100G 2 2 2 2 2 2 Malfunction 1,000 m/s 600 m/s 250 m/s 25G max. 1,000 m/s 600 m/s 1,000 m/s (See note 2) 100G max. 60G max. 100G max. 60G max. 100G max. Life Mechanical Momentary operation: Momentary operation: 500,000 100,000 500,000 expectancy 5,000,000 operations min. 300,000 operations min. operations operations operations min. min. min. Electrical 500,000 operations min. 300,000 300,000 500,000 100,000 500,000 operations operations operations operations operations min. min. min. min. min. Ambient temperature Operating: Operating: Operating: Operating: Operating: Operating: Operating: (See note 1 ) -20Cto70C -20Cto -20Cto70C -20Cto -20Cto70C -20Cto -20Cto70C (-4Fto 55C (-4Fto 55C (-4F (-4Fto 55C(-4F (-4Fto 158F) (-4Fto 158F) to 131F) 158F) to 131F) 158F) Storage: 131F) Storage: Storage: Storage: Storage: Storage: -40Cto70C Storage: -40Cto70C -40Cto -40Cto70C -40Cto -40Cto70C (-40Fto -40Cto (-40Fto 70C(-40F (-40Fto 70C(-40F (-40Fto 158F) 70C(-40F 158F) to 158F) 158F) to 158F) 158F) to 158F) Ambient humidity Operating: 35% to 85% Degree of protection IP65 Electric shock protection Class II class Degree of contamination 3 (IEC947-5-1) Note: 1. With no icing or condensation. 2. Malfunction within 1 ms. 31