New Product Remote Reset Rocker Switch A8GS Minimum size class in the industry Rocker switch with reset function Zero standby power by Reset function. High inrush-current durability. Conforming to TV-8 rating. (Inrush 117A) Model variation for Micro loads. Model variation of micro load and high capacity combination. (DPST) It is able to operate micro load and high capacity load at the same time. Contact gap of 3 mm minimum. UL and cUL standard approved, Conforming to EN standards. Model variation for 3.3VDC circuit. (Please refer the Precautions) RoHS Compliant Usage example Saving energy by cutting the standby power. Saving energy by preventing forgetting to turn OFF main power. Turning OFF main power by remote. Turning OFF main power of many equipments at the same time. * There are 2 kinds of main models A8GS. (Delay OFF Function model and Remote Reset model) With regard to the models with Delay OFF Function, please refer to the other catalog. List of Models 1. Reset function type SPST Contact Form Micro load contact terminal 1 Power contact terminal 1 1 to 2: Power contact terminal + +12 +12 a, b: Micro load contact terminal Quantity +, -: Coil terminal - a b - - per box Quick-connect terminals Terminals CT Connector Solder terminals 187 (t=0.8) Reset voltage 5V model 3.3V model 5V model 3.3V model 5V model 3.3V model No Marking A8GS-S1105 A8GS-S1103 A8GS-P1185 A8GS-P1183 A8GS-P1115 A8GS-P1113 A8GS-S1205 A8GS-S1203 A8GS-P1285 A8GS-P1283 A8GS-P1215 A8GS-P1213 Marking on caps 50 A8GS-S1305 A8GS-S1303 A8GS-P1385 A8GS-P1383 A8GS-P1315 A8GS-P1313 DPST Contact Form Micro load contact terminal 1 + Power contact terminal 1 1 to 2: Power contact terminal + 12 a, b: Micro load contact terminal +, -: Coil terminal Quantity - a b per box Micro load contact terminal : CT Connector Micro load contact terminal : CT Connector Terminals Power contact terminal : Quick-connect Power contact terminal : Solder terminals terminals 187 (t=0.8) Reset voltage 5V model 3.3V model 5V model 3.3V model No Marking A8GS-C1185 A8GS-C1183 A8GS-C1115 A8GS-C1113 A8GS-C1285 A8GS-C1283 A8GS-C1215 A8GS-C1213 Marking on caps 50 A8GS-C1385 A8GS-C1383 A8GS-C1315 A8GS-C1313 1A8GS DPST Power contact terminal 2 Contact Form 1 to 4: Power contact terminal + 12 +, -: Coil terminal Quantity per box 34 - Quick-connect terminals Terminals Solder terminals 187 (t=0.8) Reset voltage 5V model 3.3V model 5V model 3.3V model No Marking A8GS-D1185 A8GS-D1183 A8GS-D1115 A8GS-D1113 A8GS-D1285 A8GS-D1283 A8GS-D1215 A8GS-D1213 Marking on caps 50 A8GS-D1385 A8GS-D1383 A8GS-D1315 A8GS-D1313 Note: 1. V is shown at the end of model name for TV-8 approved models. (Example : A8GS-P1185V, A8GS-C1185V, A8GS-D1185V) Note: 2. TV-8 approved model is only for Power switch circuit. Note: 3. 3 is shown at the end of model name for reset voltage 3.3 VDC models. (Example : A8GS-P1183). 5 is shown at the end of model name for reset voltage 5 VDC models. (Example : A8GS-P1185). 2. Without Reset function type SPST DPST Micro load contact Power contact terminal 1 Power contact terminal 2 Contact Form terminal 1 1 to 4: Power contact terminal 12 12 a, b: Micro load contact terminal Quantity per box a b 34 Quick-connect Quick-connect Solder Solder Terminals CT Connector terminals terminals terminals terminals 187 (t=0.8) 187 (t=0.8) No Marking A8GS-S1100 A8GS-P1180 A8GS-P1110 A8GS-D1180 A8GS-D1110 A8GS-S1200 A8GS-P1280 A8GS-P1210 A8GS-D1280 A8GS-D1210 Marking on caps 50 A8GS-S1300 A8GS-P1380 A8GS-P1310 A8GS-D1380 A8GS-D1310 DPST Micro load contact terminal 1 + Power contact terminal 1 Contact Form 1 to 2 Power contact terminal 12 a, b: Micro load contact terminal Quantity per box a b Micro load contact terminal : CT Connector Micro load contact terminal : CT Connector Terminals Power contact terminal : Quick-connect Power contact terminal : Solder terminals terminals 187 (t=0.8) No Marking A8GS-C1180 A8GS-C1110 A8GS-C1280 A8GS-C1210 Marking on caps 50 A8GS-C1380 A8GS-C1310 Note: 4. These models are without reset function, it has same function with standard Rocker switch. Ratings Contact Ratings Rated current Rated voltage (Resistive load) 125 VAC 16 A Power contact terminal 250 VAC 10 A Micro load contact terminal 5 VDC 0.2 A Note: 1. The above ratings were tested under the following conditions: (1) Ambient temperature : 20 2 C (2) Ambient humidity : 65 5 % RH (3) Switching frequency : 7 times/min Reset Coil Ratings Rated voltage, Operating Coil resistance Model Rated usage cycle current voltage range (Coil temperature: 20 2 C) Reset voltage : 5V model ON: 50 to 100 ms 5VDC 455 mA 4.5 to 5.5 VDC 11 20 % (A8GS- 5) OFF: Min 5 sec Reset voltage : 3.3V model ON: 50 to 100 ms 3.3VDC 300 mA 3.0 to 3.6 VDC 11 20 % (A8GS- 3) OFF: Min 5 sec Note: 1. Voltage for coil should be set within operating voltage range and applied time should be within rated usage cycle. Otherwise the performance of the coil may be deteriorated. Note: 2. In case of applying voltage within the range from 5.5 to 24 VDC to the coil, contact your OMRON sales representative. 2