Remote Reset Rocker Switch
A8GS
Minimum size class in the industry Rocker switch with reset function
Zero standby power by Reset function.
High inrush-current durability.
Conforming to TV-8 rating. (Inrush 117A)
Model variation for Micro loads.
Model variation of micro load and high capacity combination. (DPST)
It is able to operate micro load and high capacity load at the same time.
Contact gap of 3 mm minimum.
UL and cUL standard approved, Conforming to EN standards.
Model variation for 3.3VDC circuit.
(Please refer the Precautions)
RoHS Compliant
Usage example
Saving energy by cutting the standby power.
Saving energy by preventing forgetting to turn OFF main power.
Turning OFF main power by remote.
Turning OFF main power of many equipments at the same time.
* There are 2 kinds of main models A8GS. (Delay OFF Function model and Remote Reset model) With regard to the models with Delay OFF Function, please refer to the other catalog.
List of Models
1. Reset function type
SPST
Contact Form
Micro load contact terminal 1 Power contact terminal 1
1 to 2: Power contact terminal
+ +12 +12
a, b: Micro load contact terminal
Quantity
+, -: Coil terminal
- a b - - per box
Quick-connect terminals
Terminals CT Connector Solder terminals
#187 (t=0.8)
Reset voltage 5V model 3.3V model 5V model 3.3V model 5V model 3.3V model
No Marking A8GS-S1105 A8GS-S1103 A8GS-P1185 A8GS-P1183 A8GS-P1115 A8GS-P1113
A8GS-S1205 A8GS-S1203 A8GS-P1285 A8GS-P1283 A8GS-P1215 A8GS-P1213
Marking on caps 50
A8GS-S1305 A8GS-S1303 A8GS-P1385 A8GS-P1383 A8GS-P1315 A8GS-P1313
DPST
Contact Form
Micro load contact terminal 1 + Power contact terminal 1
1 to 2: Power contact terminal
+
12
a, b: Micro load contact terminal
+, -: Coil terminal
Quantity
- a b
per box
Micro load contact terminal : CT Connector
Micro load contact terminal : CT Connector
Terminals Power contact terminal : Quick-connect
Power contact terminal : Solder terminals
terminals #187 (t=0.8)
Reset voltage 5V model 3.3V model 5V model 3.3V model
No Marking A8GS-C1185 A8GS-C1183 A8GS-C1115 A8GS-C1113
A8GS-C1285 A8GS-C1283 A8GS-C1215 A8GS-C1213
Marking on caps 50
A8GS-C1385 A8GS-C1383 A8GS-C1315 A8GS-C1313
1A8GS
DPST
Power contact terminal 2
Contact Form
1 to 4: Power contact terminal
+
12
+, -: Coil terminal
Quantity
per box
34
-
Quick-connect terminals
Terminals Solder terminals
#187 (t=0.8)
Reset voltage 5V model 3.3V model 5V model 3.3V model
No Marking A8GS-D1185 A8GS-D1183 A8GS-D1115 A8GS-D1113
A8GS-D1285 A8GS-D1283 A8GS-D1215 A8GS-D1213
Marking on caps 50
A8GS-D1385 A8GS-D1383 A8GS-D1315 A8GS-D1313
Note: 1. [ V ] is shown at the end of model name for TV-8 approved models. (Example : A8GS-P1185V, A8GS-C1185V, A8GS-D1185V)
Note: 2. TV-8 approved model is only for Power switch circuit.
Note: 3. [ 3 ] is shown at the end of model name for reset voltage 3.3 VDC models. (Example : A8GS-P1183).
[ 5 ] is shown at the end of model name for reset voltage 5 VDC models. (Example : A8GS-P1185).
2. Without Reset function type
SPST DPST
Micro load contact
Power contact terminal 1 Power contact terminal 2
Contact Form
terminal 1
1 to 4: Power contact terminal
12 12
a, b: Micro load contact terminal Quantity
per box
a b 34
Quick-connect Quick-connect
Solder Solder
Terminals CT Connector terminals terminals
terminals terminals
#187 (t=0.8) #187 (t=0.8)
No Marking A8GS-S1100 A8GS-P1180 A8GS-P1110 A8GS-D1180 A8GS-D1110
A8GS-S1200 A8GS-P1280 A8GS-P1210 A8GS-D1280 A8GS-D1210
Marking on caps 50
A8GS-S1300 A8GS-P1380 A8GS-P1310 A8GS-D1380 A8GS-D1310
DPST
Micro load contact terminal 1 + Power contact terminal 1
Contact Form
1 to 2 Power contact terminal
12
a, b: Micro load contact terminal
Quantity
per box
a b
Micro load contact terminal : CT Connector
Micro load contact terminal : CT Connector
Terminals Power contact terminal : Quick-connect
Power contact terminal : Solder terminals
terminals #187 (t=0.8)
No Marking A8GS-C1180 A8GS-C1110
A8GS-C1280 A8GS-C1210
Marking on caps 50
A8GS-C1380 A8GS-C1310
Note: 4. These models are without reset function, it has same function with standard Rocker switch.
Ratings
Contact Ratings
Rated current
Rated voltage
(Resistive load)
125 VAC 16 A
Power contact terminal
250 VAC 10 A
Micro load contact terminal 5 VDC 0.2 A
Note: 1. The above ratings were tested under the following conditions:
(1) Ambient temperature : 20 2 C
(2) Ambient humidity : 65 5 % RH
(3) Switching frequency : 7 times/min
Reset Coil Ratings
Rated voltage, Operating Coil resistance
Model Rated usage cycle
current voltage range (Coil temperature: 20 2 C)
Reset voltage : 5V model ON: 50 to 100 ms
5VDC 455 mA 4.5 to 5.5 VDC 11 20 %
(A8GS-@@@@5) OFF: Min 5 sec
Reset voltage : 3.3V model ON: 50 to 100 ms
3.3VDC 300 mA 3.0 to 3.6 VDC 11 20 %
(A8GS-@@@@3) OFF: Min 5 sec
Note: 1. Voltage for coil should be set within operating voltage range and applied time should be within rated usage cycle.
Otherwise the performance of the coil may be deteriorated.
Note: 2. In case of applying voltage within the range from 5.5 to 24 VDC to the coil, contact your OMRON sales representative.