D2A Ultra Subminiature Detection Switch Ultra Subminiature Detection Switch with Slide Mechanism and Pushbutton Actuator D Compact, light weight, and 3 mm long stroke. 2 Built-in slide mechanism allows selection of A shorting or non-shorting switching timing of the switch. RoHS Compliant Model Number Legend Contact form SPDT 1 2 D2A- 1 0 1. Switching timing 1: Non-shorting Model 2: Shorting Model NO COM NC 3 1 2 2. Maximum Operating Force (OF) 1: 0.98 N 100 gf Contact specifications 2: 0.49 N 50 gf Specification Slide Contact List of models Material Silver plated Minimum applicable load Operating Force (OF) 0.98N (standard) 0.49N (low operating force) 5 VDC 1mA (reference value) * Switching timing Non-shorting Model Shorting Model Non-shorting Model Shorting Model Actuator * Please refer to theUsing Micro Load in Precaution for more information on the minimum Pin D2A-1110 D2A-2110 D2A-1120 D2A-2120 applicable load. plunger Ratings Characteristics Rated voltage Resistive load Permissible operating speed 1 mm to 500 mm/s 30 VDC 0.1 A Mechanical 200 operations/min Permissible operating frequency Electrical 30 operations/min Note. The ratings values apply under the following test conditions. Insulation resistance 100 M min. (at 250 VDC with insulation tester) (1) Ambient temperature: 202C Contact resistance (initial value) 50 m max. (2) Ambient humidity: 655% (3) Operating frequency: 30 operations/min Between terminals of the 250 VAC 50/60 Hz 1 min same polarity Dielectric strength Between current-carrying 250 VAC 50/60 Hz 1 min metal parts and ground Vibration resistance Malfunction between 10 to 55 Hz, 1.5 mm-double amplitude *1 2 Durability 1,000 m/s approx. 100G max. Shock resistance 2 Malfunction *1 300 m/s approx. 30G max. Durability *2 50,000 operations min. (30 operations/min) Degree of protection IEC IP00 -10C to +80C (at ambient humidity 60% max.) Ambient operating temperature (with no icing or condensation) Ambient operating humidity 85% max. (for +5C to +35C) Weight Approx. 0.3 g Note.The data given above are initial values. *1. The values are at Free Position and Total Travel Position. Close or open circuit of contact is 1ms max. *2. For testing conditions, consult your OMRON sales representative. 1D2A Ultra Subminiature Detection Switch Mounting Holes (unit: mm) M2 Tap 0.1 3.8 0.1 5.5 1.6 dia. holes Dimensions (unit: mm) and Operating Characteristics D2A-1110, D2A-1120 FP Models Non- Shorting Model Shorting Model D OP 5.6 D2A-2110, D2A-2120 2 Operating Model D2A D2A D2A D2A 6.5 4.2 +0.12 characteristics -1110 -1120 -2110 -2120 A 2 dia. holes 0.15 0 5.5 1.6 Operating Force OF Max 0.98 N 0.49 N 0.98 N 0.49 N 1.4 100 gf 50 gf 100 gf 50 gf 6 A Releasing Force RF Min. 0.15 N 0.05 N 0.15 N 0.05 N 0.15 3.8 4.5 4 15 gf 5 gf 15 gf 5 gf 1 Free Position FP Max. 9.5 mm 9.5 mm 0 1.5 dia. 3.5 -0.12 Operating Position OP1 8.10.3 mm 8.00.3 mm OP2 7.40.3 mm 7.50.3 mm 0.8 0.3 Total Travel Position TTP 6.50.2 mm 6.50.2 mm 0.9 2.54 2.54 4 <PCB Mounting Dimensions (Reference)> 8 2.54 Switching timing 3-1 dia. holes Non-shorting Model Shorting Model FP OP1 OP2 TTP FP OP1 OP2 TTP 2.54 2 NC 2 NC 4.2 1 1 3 NO 3 NO 8 Note1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. Note2. The operating characteristics are for operation in the A direction ( ). Precautions Please refer toCommon Precaution for correct use. Mounting Plate Cautions Use materials other than ABS or polycarbonate for the mounting plate. Since grease is used for the Switch, cracks may occur if Soldering grease from the Switch comes in contact with such materials. For soldering time, we recommend to solder within 3 seconds at Using Micro Loads a soldering iron temperature of less than 350C. When soldering It is recommended to use the Switch in the operation range exceeds this temperature and time, or repeated soldering will shown below. However, even when using micro load models degrade the Switch characteristics. within the following operating range, if inrush current occurs Make sure that flux and liquid when the contact is opened or closed, it may increase the surface of the solder do not flow Switch mounti surface contact wear and so decrease durability. Therefore, insert a over the edge of the board when contact protection circuit where necessary. The minimum soldering. Please complete applicable load is the N-level reference value. This value soldering at a temperature of indicates the malfunction reference level for the reliability level of 260C within 5 seconds. 60% (60). (JIS C5003) It is also recommended that you apply flux guard to the mounting -6 The equation, 60=0.510 /operation, indicates that the surface of the Switch. 1 estimated malfunction rate is less than operations with 2,000,000 Correct Use a reliability level of 60%. Mounting Use M2 mounting screw with plane washers or spring washers to 0.16 mA 100 mA 30 mount the Switch. Tighten the screws to a torque of 4.9 to -2 9.810 N m 0.5 to 1kgf cm . 24 Application of Operation Force to the Actuator Do not apply operation forces other than in the operating Operating range direction of the lever as shown in the following figure. It may damage the Switch or 12 cause malfunction. 5 1 mA 0 0.1 1 10 100 1,000 Current (mA) 2 Voltage (V)