D2FS Ultra Subminiature Basic Switch Simple construction and high reliability for long time Developed for a few number of operations during a long period of use such as door-detection to avoid sabotage on meters. Simple construction with a single-leaf movable spring realizes reasonable cost. Self-clinching, right-angled and left-angled PCB terminals are also available. RoHS Compliant Model Number Legend D2FS-F -N 12 1. Actuator None : Pin plunger L : Hinge lever 2. Terminals None : PCB terminals (Straight) -T : PCB terminals (Self-clinching) -A : PCB terminals (Right-angled) -A1 : PCB terminals (Left-angled) List of Models Actuator Terminals Model Pin plunger PCB terminals (Straight) D2FS-F-N PCB terminals (Self-clinching) D2FS-F-N-T PCB terminals (Right-angled) D2FS-F-N-A PCB terminals (Left-angled) D2FS-F-N-A1 Hinge lever PCB terminals (Straight) D2FS-FL-N PCB terminals (Self-clinching) D2FS-FL-N-T PCB terminals (Right-angled) D2FS-FL-N-A PCB terminals (Left-angled) D2FS-FL-N-A1 Contact Form SPST-NO COM NO Contact Specifications Specification Crossbar Contact Material Silver Gap (standard value) 0.4 mm Minimum applicable load (see note) 1 mA at 5 VDC Note: For more information on the minimum applicable load, refer to Using Micro Loads. 1D2FS Ultra Subminiature Basic Switch Ratings Rated voltage Resistive load 6 VDC 0.1 A Note: The rating values apply under the following test conditions. Ambient temperature: 20 2C Ambient humidity: 65 5% Operating frequency: 20 operations/min Characteristics Pin plunger models: 1 mm to 500 mm/s Operating speed Lever models: 5 mm to 500 mm/s Pin plunger models: 200 operations/min max. Mechanical Lever models: 100 operations/min max. Operatiing frequency Electrical 30 operations/min max. Insulation resistance 100 M min. (at 500 VDC) Contact resistance (initial value) 100 m max. Between terminals of same polarity 600 VAC 50/60 Hz 1 min Between current carrying metal parts and ground Dielectric strength 1,500 VAC 50/60 Hz 1 min Between each terminal and non-current carrying metal part Vibration resistance Malfunction *1 10 to 55 Hz, 1.5 mm double amplitude 2 Destruction 1,000 m/s max. Shock resistance 2 Malfunction *1 300 m/s max. Mechanical 100,000 operations min. (at 30 ops./min.) Durability *2 Electrical 10,000 operations min. (at 30 ops./min.) Degree of protection IP40 Ambient operatingtamperature 20 to +70C (at 60%RH Max.) (with no icing or condensation) Ambient operation humidity 85%RH max. (for +5 to +35C) Weight Approx. 0.5 g (pin plunger models) Note: The data given above are initial values. *1. The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever. Close or open circuit of the contact is 1 ms max. *2. For testing conditions, consult your OMRON sales representative. 2