D2S Subminiature Basic Switch Subminiature Switch with Superb Flux Resistance One-piece terminal construction to keep out flux. High operating-position accuracy (0.25 mm) enables easy peripheral design and positioning. D Use of pin plunger also allows horizontal 2 S operation. RoHS Compliant Model Number Legend 12 3 4 D2S- 1. Ratings 3. Maximum Operating Force (OF) 10 : 250 VAC 10.1 A None : 1.47 N 150 gf 5 : 125 VAC 5 A -F : 0.49 N 50 gf (For 0.1 A, 5 A) 01 : 30 VDC 0.1 A Note: The given values are for pin plunger models only. 2. Actuator 4. Terminals None : Pin plunger None : Solder terminals L : Hinge lever D : Self-clinching PCB terminals L13 : Simulated roller lever L2 : Hinge roller lever List of Models Ratings 10.1 A 5 A 0.1 A Actuator Terminals OF max. 1.47 N 150 gf D2S-10 D2S-5 D2S-01 Solder terminals Pin plunger 0.49 N 50 gf - D2S-5-F D2S-01-F 1.47 N 150 gf D2S-10D D2S-5D D2S-01D Self-clinching PCB terminals 0.49 N 50 gf - D2S-5-FD D2S-01-FD 0.49 N 50 gf D2S-10L D2S-5L D2S-01L Hinge lever Solder terminals 0.18 N 18 gf - D2S-5L-F D2S-01L-F 0.49 N 50 gf D2S-10LD D2S-5LD D2S-01LD Self-clinching PCB terminals 0.18 N 18 gf - D2S-5L-FD D2S-01L-FD 0.49 N 50 gf D2S-10L13 D2S-5L13 D2S-01L13 Simulated roller lever Solder terminals 0.18 N 18 gf - D2S-5L13-F D2S-01L13-F 0.49 N 50 gf D2S-10L13D D2S-5L13D D2S-01L13D Self-clinching PCB terminals 0.18 N 18 gf - D2S-5L13-FD D2S-01L13-FD 0.49 N 50 gf D2S-10L2 D2S-5L2 D2S-01L2 Hinge roller lever Solder terminals 0.18 N 18 gf - D2S-5L2-F D2S-01L2-F 0.49 N 50 gf D2S-10L2D D2S-5L2D D2S-01L2D Self-clinching PCB terminals 0.18 N 18 gf - D2S-5L2-FD D2S-01L2-FD Separator (Sold Separately), Terminal Connector (Sold Separately) Refer toBasic Switch Common Accessorie 1D2S Subminiature Basic Switch Contact Form SPDT COM NO NC Contact Specifications D Item Model D2S-10 models D2S-5 models D2S-01 models 2 Specification Rivet Crossbar S Material Silver alloy Gold alloy Contact Gap (standard 0.5 mm value) NC 20A max. 1 A max. Inrush current NO 15 A max. 10 A max. 1 A max. Minimum applicable load 5 VDC 160 mA 5 VDC 1 mA (reference value) * * Please refer toUsing Micro Load ofPrecaution for more information on the minimum applicable load. Ratings Characteristics Item Item Model D2S-10 models D2S-5 models D2S-01 models Resistive load Model Rated voltage Permissible operating speed 0.1 mm to 1 m/s (for pin plunger models) D2S-10 250 VAC 10.1 A Permissible Mechanical 400 operations/min models operating Electrical 60 operations/min D2S-5 125 VAC 5 A frequency models 250 VAC 3 A Insulation resistance 100 M min. (at 500 VDC with insulation tester) 125 VAC 0.1 A D2S-01 OF 1.47 N models 30m max. 50 m max. Contact resistance models 30 VDC 0.1 A (initial value) OF 0.49 N models - 50 m max. 100 m max. Note. The above rating values apply under the Between terminals of the same 1,000 VAC 50/60 Hz 1 min following test conditions. polarity (1) Ambient temperature: 202C Dielectric Between current-carrying metal (2) Ambient humidity: 655% 1,500 VAC 50/60 Hz 1 min strength * 1 parts and ground (3) Operating frequency: 30 operations/min Between each terminals and 1,500 VAC 50/60 Hz 1 min non-current-carrying metal parts Approved Safety Vibration Malfunction 10 to 55 Hz, 1.5 mm double amplitude Standards resistance * 2 2 OF 1.47 N models 1,000 m/s approx. 100G max. The items shown in theList of Model Durability 2 OF 0.49 N models 500 m/s approx. 50G max. Shock are not standard approved models. resistance 2 OF 1.47 N models 300 m/s approx. 30G max. Consult your OMRON sales Malfunction * 2 2 OF 0.49 models 200 m/s approx. 20G max. representative for specific models with 10,000,000 operations min. 30,000,000 operations min. standard approvals. Mechanical (60 operations/min) (60 operations/min) Durability * 3 UL (UL1054)/CSA(CSA C22.2 No.55) 50,000 operations min. 200,000 operations min. Electrical (30 operations/min) (30 operations/min) Rated D2S-10 D2S-5 D2S-01 voltage Model Degree of protection IEC IP40 125 VAC - 5 A 0.1 A -25C to +85C (at ambient humidity of 60% max.) Ambient operating temperature 250 V 10.1 A 3 A - (with no icing or condensation) 30 VDC - - 0.1 A Ambient operating humidity 85% max. (for +5C to +35C) Weight Approx. 1.6 g (pin plunger models) Note. The data given above are initial values. *1. The values for dielectric strength shown are for models with a Separator (refer toMicro Switch Common Accessorie). *2. The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever. Close or open circuit of the contact is 1ms max. *3. For testing conditions, consult your OMRON sales representative. 2