Sealed Snap Action Switch
D2VW
Watertight Miniature Snap Action Switch
High-quality watertight, high-precision miniature Snap
Action switch. Switch Body meets IP67 requirements
Use of epoxy resin assures high sealing capability and is
ideal for dusty places or where water is sprayed
V-series internal mechanism assures high precision and
long life
General-load (5 A at 250 VAC) models and micro-load
models are available
RoHS Compliant
Ordering Information
Actuator Terminal Model
Model 0.1 A Model 5 A
Pin plunger With solder and #187 tab terminals D2VW-01-1HS D2VW-5-1HS
With lead wires D2VW-01-1MS D2VW-5-1MS
Short hinge lever With solder and #187 tab terminals D2VW-01L1A-1HS D2VW-5L1A-1HS
With lead wires D2VW-01L1A-1MS D2VW-5L1A-1MS
Hinge lever With solder and #187 tab terminals D2VW-01L1-1HS D2VW-5L1-1HS
With lead wires D2VW-01L1-1MS D2VW-5L1-1MS
Long hinge lever With solder and #187 tab terminals D2VW-01L1B-1HS D2VW-5L1B-1HS
With lead wires D2VW-01L1B-1MS D2VW-5L1B-1MS
Simulated roller lever With solder and #187 tab terminals D2VW-01L3-1HS D2VW-5L3-1HS
With lead wires D2VW-01L3-1MS D2VW-5L3-1MS
Short hinge roller lever With solder and #187 tab terminals D2VW-01L2A-1HS D2VW-5L2A-1HS
With lead wires D2VW-01L2A-1MS D2VW-5L2A-1MS
Hinge roller lever With solder and #187 tab terminals D2VW-01L2-1HS D2VW-5L2-1HS
With lead wires D2VW-01L2-1MS D2VW-5L2-1MS
Note: 1. The standard lengths of the lead wires (UL1015 AWG20 for UL/CSA models, AV0.75f otherwise) of models incorporating them are 300 mm.
Add -0 to the end of the part number to obtain 1,000 mm long wires. (e.g.: D2VW-5L2A-1MS-0)
2. Remove -HS from the end of solder/quick-connect models to obtain non-UL/CSA versions. (e.g.: D2VW-01-1HS D2VW-01-1)
3. Remove S from the end of lead wire models to obtain non-UL/CSA versions with AV0.75f wire. (e.g.: D2VW-5L3-1MS D2VW-5L3-1M)
Model Number Legend
D2VW- - -
1 2 3 4 5
1. Ratings 2. Actuator 3. Contact Form 4. Terminals
5: 5 A at 250 VAC None: Pin plunger 1: SPDT
None, HS: Solder terminals
(HS for UL and CSA approval.)
01: 0.1 A at 30 VDC L1A: Short hinge lever 2: SPST-NC
M, MS: Molded lead wires
L1: Hinge lever 3: SPST-NO
(MS for UL and CSA approval)
L1B: Long hinge lever
L3: Simulated roller lever
5. Length of the molded lead wire
L2A: Short hinge roller lever
None: 300 mm
L2: Hinge roller lever
0: 1,000 mm
Sealed Snap Action Switch D2VW 1Specifications
Characteristics
Model D2VW-01 D2VW-5
Operating speed 0.1 mm to 1 m/s (at pin plunger)
Operating frequency Mechanical: 300 operations/minute max.
Electrical: 60 operations/minute max.
Insulation resistance 100 M min. (at 500 VDC)
Contact resistance 50 m max. for solder terminal models
100 m max. for 300 mm molded lead wire models
200 m max. for 1,000 mm molded lead wire models
Dielectric strength (See note 2) 1,000 VAC, 50/60 Hz for 1 min. between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min. between each current-carrying metal parts and ground, and
between each terminal and non-current-carrying metal parts.
Vibration resistance (See note 3) Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
2
Shock resistance (See note 3)
Destruction: 1,000 m/s (approx. 100G) max.
2
Malfunction: 300 m/s (approx. 30G) max.
Degree of protection IEC IP67 (excluding the terminals on terminal models).
Degree of protection against electric shock Class I
Proof tracking index (PTI) 175
Ambient operating temperature -40 to 85C (at 60% RH max.) with no icing
Ambient operating humidity 95% max. (for 5Cto35C)
Life expectancy Mechanical 10,000,000 operations min. at 60 operations per minute
Electrical 1,000,000 operations min. at 30 ops. per minute. 100,000 operations min. at 30 ops. per minute
Weight Approx. 7g (pin plunger models without wires)
Note: 1. Data shown are of initial value.
2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate.
3. For the pin plunger models, the above values apply for use at the free position and total travel position. For the lever models, the values
apply at the total travel position.
4. The operating temperature of the lead wire (AV0.75f) for non-UL/CSA molded lead wire models is between -40 to 85C.
Ratings (reference values)
D2VW-5
Rated Voltage Non-inductive load Inductive load
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC 5 A 0.5 A 4 A
250 VAC 5 A 0.5 A 4 A
30VDC 5A 3A 4A
125 VDC 0.4 A 0.1 A 0.4 A
D2VW-01
Rated Voltage Non-inductive load Inductive load
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC 0.1 A
30 VDC 0.1 A
Note: 1. The resistive load ratings apply under the following test conditions:
Ambient Temperature = 202C, Ambient Humidity = 655%, Operating frequency = 30 operations/min.
2. The above current ratings are the values of the steady-state current.
3. Inductive load has a power factor of 0.7 min. (AC) and a time constant of 7 ms max. (DC).
4. Lamp load has an inrush current of 10 times the steady-state current.
5. Rating for UL/CSA approval is as follows (See Approved Standards section):
D2VW-01 0.1A @ 125 VAC
0.1A @ 30 VDC
D2VW-5 3A @ 125 VAC, 250 VAC
2 Sealed Snap Action Switch D2VW