Detection Switch
D2X
Switch with Crimp Connector
Reduced wiring time with AMP crimp-type connectors
Snap-fit attachment for easy installation
Actuator operates from either side, allowing mounting in
either direction
High contact force and wiping action for greater contact
reliability
Rated load 0.1 A at 30 VDC
RoHS Compliant
Ordering Information
Actuator Terminal Contact OF Model
Standard Model
Center mounted rotary lever Crimp-type connector 50 g D2X-C
Specifications
Characteristics
Electrical ratings 0.1 A, 30 VDC (resistive load)
Operating speed 0.1 mm to 100 mm/second
Operating frequency Mechanical: 60 operations per minute
Electrical: 30 operations per minute
Contact resistance 200 m max.
Insulation resistance 100 M min. at 250 VDC
Dielectric strength 250 VAC, 50/60 Hz for 1 minute between terminals of same polarity
250 VAC, 50/60 Hz for 1 minute between current-carrying metal parts and ground
Vibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
2
Shock resistance
Destruction: 500 m/s (approx. 50G) max.
2
Malfunction: 300 m/s (approx. 30G) max.
Degree of protection IEC IP00
Degree of protection against electric shock Class I
Proof tracking index (PTI) 175
Ambient operating temperature -10 to 70 C (at 60% RH max.) with no icing
Ambient operating humidity 45% to 85% (for 5 C to 35 C)
Service life Mechanical: 1,000,000 operations min.
Electrical: 50,000 operations min.
Weight Approx. 1 g
Note: 1. Data shown are of initial value.
2. The ratings apply under the following test conditions: Ambient Temperature = 202 C, Ambient Humidity = 65 5%, Operating frequency = 30 operations/min.
Detection Switch D2X 41Engineering Data
Contact Specifications Contact Form
Item Specification
Specification Slide
Material Gold plated
Minimum applicable load 1 mA at 5 VDC
(see note)
Note: Minimum applicable loads are indicated by N standard
reference values. This value represents the failure rate at a
60% ( ) reliability level (JIS C5003).
60
-6
The equation =0.5 x 10 /operations indicates that a failure
60
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%.
Panel Mounting Holes
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of 0.1 mm applies to all dimensions
2. The tolerance from the center of each hole is 0.07
3. Make sure that any burrs are located on the backside of the mounting plate
With 1.6 mm panel thickness With 1.2 mm panel thickness
Two, 0.6R
Two, 0.6R
Eight, 1R 4.8 12.9
1.8
3.20.05 dia.
Two, 0.5R
+0.8
3.20.05 dia.
4.4
10.8
3.5 0
Two, 0.5R
+0.1
3.2 Two,
+0.8
dia. 0
80.1 5.2
4.4 Two, 10.8
dia. 0
0.5R
0.5R
Two,
1.6R
5 3.4
+0.1
3.2
0
12.2
4 5
Four, 1R
2.70.1
4.9
Two, 0.6R Two, 0.6R
Dimensions
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of 0.4 mm applies to all dimensions.
2. The operating characteristics are for cases where the actuator operates in the A ( ) direction or B () direction.
D2X-C Hub on back side
Center of two, 3.1-dia. holes
OF 50 g
Direction A Direction B
RF min. 2 g
TTP OP 2 to 9 max. or 0.52 to 2.35 mm
Stroke measurement reference Stroke measurement reference
TTP max. 25 or 6.34 mm
position Direction B: 20 position Direction A: 20
OP max.
4.8
(0.2)
OP min.
Center Line
Direction A Direction B
1.55
Two, 3.1 dia.
0.52 min. 0.52 min.
15
ON
OFF
2.35 max. 2.35 max.
3.8
11.9 12.2
8
(17)
6
Total travel position Total travel position
6.34 min. 6.34 min.
5.1
*
Total stroke of actuator (mm)
0.4
1 1.6
5.8
3.3
6.2
*Use AMPs CT Connector
5.3
type 173977-2.
42 Detection Switch D2X