Miniature Limit Switch D4CC CSM D4CC DS E 3 1 Many Models Including Roller Lever Switches are Only 16-mm Thick with Connector New center roller lever models that enable ganged mounting of up to 6 Switches. Cable connectors for easy Switch replacement. Triple-seal construction to provide IEC IP67 degree of protection. Operation indicators available for easy monitoring (standard indicator is lit when Switch is not operating). Approved by UL and CSA. (Ask your OMRON representative for Information on approved models.) Be sure to read Safety Precautions on page 7 to 8 and Safety Precautions for All Limit Switches. Model Number Structure Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) (2) Actuator D4CC- 0 01 : Pin plunger (1) (2) 02 : Roller plunger 03 : Crossroller plunger (1) Rated Current 24 : Roller lever 1 : 1 A at 125 VAC 31 : Sealed pin plunger 2 : 1 A at 125 VAC (with LED indicator) 32 : Sealed roller plunger 3 : 1 A at 30 VDC 33 : Sealed crossroller plunger 4 : 1 A at 30 VDC (with LED indicator) 50 : Plastic rod 60 : Center roller lever Ordering Information Switches Limit Switches Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator Model Model Model Model Pin D4CC-1001 D4CC-2001 D4CC-3001 D4CC-4001 plunger Roller D4CC-1002 D4CC-2002 D4CC-3002 D4CC-4002 plunger Crossroller D4CC-1003 D4CC-2003 D4CC-3003 D4CC-4003 plunger High-sensitivity D4CC-1024 D4CC-2024 D4CC-3024 D4CC-4024 roller lever Sealed pin D4CC-1031 D4CC-2031 D4CC-3031 D4CC-4031 plunger Sealed roller D4CC-1032 D4CC-2032 D4CC-3032 D4CC-4032 plunger Sealed crossroller D4CC-1033 --- D4CC-3033 D4CC-4033 plunger Plastic D4CC-1050 D4CC-2050 D4CC-3050 D4CC-4050 rod Center D4CC-1060 D4CC-2060 D4CC-3060 D4CC-4060 roller lever Note: 1. Ask your OMRON representative for Information on approved models. 2. The meaning of suffix codes in the D4CC model numbers is different from that in the D4C model numbers. 3. Refer to the following table for cable plugs. 1D4CC Applicable Cables Type For AC For DC No. of Model Model Appearance conductors Cable length Straight 1 m XS2F-A421-C90-A XS2F-D421-C80-A XS2F-A421-D90-A XS2F-D421-D80-A 2 m 4 5 m XS2F-A421-G90-A XS2F-D421-G80-A XS2F-A421-J90-A XS2F-D421-J80-A 10 m Special Mounting Plate (Order Separately) It is possible to replace an WL Limit Switch with a D4CC Limit Switch mounted on this plate without changing the position of the dog or cam. List of Replaceable Models Example of Replacement Note: The position of the dog remains unchanged. WL model D4CC model Plate (Actuator) (Actuator) WLD D4CC- 001 D4C-P001 (Top plunger) (Plunger) Dog Dog WLD2 D4CC- 002 D4C-P002 (Top roller plunger) (Roller plunger) WLG2 D4CC- 024 D4C-P020 (Roller lever) (Roller lever) Mounting plate Specifications Approved Standards Characteristics Degree of protection IP67 Agency Standard File No. Mechanical 10,000,000 operations min. UL UL508 E76675 Durability *1 Electrical 200,000 operations min. (1 A at 125 VAC, resistive load) CSA CSA C22.2 No. 14 LR45746 0.1 mm/s to 0.5 m/s (in case of plunger) Operating speed 1 mm/s to 1 m/s (in case of roller lever) Ratings Mechanical 120 operations/min Operating Non-inductive load (A) Inductive load (A) frequency Electrical 30 operations/min Rated Resistive Inductive Rated frequency 50/60 Hz Lamp load Motor load voltage load load Insulation resistance 100 M min. (at 500 VDC) NC NO NC NO NC NO NC NO Contact resistance (initial) 100 m max. 125 VAC 111 0.7 111 1 Between terminals 1,000 VAC, 50/60 Hz for 1 min of same polarity 30 VDC 1111 111 1 Between current- Note: 1. The above current ratings are for steady-state current. Dielectric carrying metal 1,500 VAC, 50/60 Hz for 1 min 2. Inductive loads have a power factor of 0.4 min. (AC) and a time strength parts and ground constant of 7 ms max. (DC). 3. Lamp loads have an inrush current of 10 times the steady-state current. Between each termi- 4. Motor loads have an inrush current of 6 times the steady-state current. nal and non-current- 1,500 VAC, 50/60 Hz for 1 min carrying metal part D4CC-3, D4CC-4, 1 A at 30 VDC Vibration Malfunction 10 to 55 Hz, 1.5-mm double amplitude *2 resistance NC 5 A max. Inrush 2 Destruction 1,000 m/s min. Shock current NO 2.5 A max. 2 resistance Malfunction 500 m/s min. *2 Ambient operating temperature 10C to +70C (with no icing) Approved Standard Ratings Ambient operating humidity 35% to 95%RH UL/CSA Weight Approx. 120 g (in the case of D4CC-1002) D4CC-1, D4CC-2 Note: The above figures are initial values. D150 *1. The values are calculated at an operating temperature of +5C to +35C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales Current (A) Volt-amperes (VA) Rated Carry representative for more detailed information on other operating voltage current environments. Make Break Make Break *2. Excluding plastic rod models. 120 VAC 1.0 A 3.6 0.6 432 72 Leakage Current for Switches with Indicators The leakage current and resistance of Switches with indicators are as follows: Item Model D4CC-2 D4CC-4 Voltage 125 VAC 30 VDC Leakage current 1.0 mA 1.0 mA Resistive value 150 k 30 k 2