Enclosed Switch D4MC CSM D4MC DS E 2 2 Economical, High Utility Enclosed Switch Enclosed Switches with Built-in Basic Switches for High Repeatability and Durability of 10 Million Operations Minimum. Panel mount versions have the same operating position as Z Basic Switch. Suitable for applications demanding higher mechanical strength, dustproof and drip-proof properties than those on basic switches. Resin molded terminal versions are available. Approved by UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.) For the most recent information on models that have been certified for Be sure to read Safety Precautions on page 5 and Safety Precautions for All safety standards, refer to your OMRON website. Limit Switches. Model Number Structure Ordering Information Model Number Legend Actuator Model D4MC- D4MC-5000 Panel mount plunger (1) (2) Panel mount roller (1) Actuator D4MC-5020 plunger 500: Panel mount plunger 502: Panel mount roller plunger Panel mount 504: Panel mount crossroller plunger D4MC-5040 crossroller plunger 100: Hinge lever 102: Short hinge lever 200: Hinge roller lever Hinge lever D4MC-1000 202: Short hinge roller lever 303: One-way action short hinge roller lever Short hinge lever D4MC-1020 (2) Location of Cable Outlet 0: None Hinge roller lever D4MC-2000 1: Right-hand (Molded terminals) 2: Left-hand (Molded terminals) 3: Underside (Molded terminals) Short hinge roller D4MC-2020 lever One-way action short D4MC-3030 hinge roller lever Note: 1. Use Switches with molded terminals in locations subject to dirt, dust, oil drops, or high humidity. Models are available with lead wires on the right, on the left, and from the bottom. 2. Contact your OMRON representative for information on models certified for international standards. Specifications Approved Standards Agency Standard File No. UL * UL508, CSA C22.2 No.14 E76675 CCC(CQC) GB14048.5 2003010303077627 Note: Ask your OMRON representative for information on approved models. * UL certified for CSA C22.2 No. 14. 1D4MC Ratings Approved Standard Ratings Non-inductive load (A) Inductive load (A) UL/CSA Rated Resistive load Lamp load Inductive load Motor load A300 voltage NC NO NC NO NC NO NC NO Current (A) Volt-amperes (VA) Carry 125 VAC 10 3 1.5 10 5 2.5 Rated voltage current Make Break Make Break 250 VAC 10 2.5 1.25 10 3 1.5 480 VAC 3 1.5 0.75 2.5 1.5 0.75 120 VAC 60 6 10A 7,200 720 8 VDC 10 3 1.5 6 5 2.5 240 VAC 30 3 14 VDC 10 3 1.5 6 5 2.5 30 VDC 6 3 1.5 5 5 2.5 125 VDC 0.5 0.4 0.4 0.05 0.05 0.05 EN60947-5-1 250 VDC 0.25 0.2 0.2 0.03 0.03 0.03 CCC (GB14048.5) NC 30 A max. Inrush current Applicable category and ratings NO 15 A max. AC-12 10 A/250 VAC Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. Lamp load has an inrush current of 10 times the steady-state current. 4. Motor load has an inrush current of 6 times the steady-state current. 5. The above ratings were tested under the following conditions. (1) Ambient temperature: +202C (2) Ambient humidity: 655%RH (3) Operating frequency: 20 operations/min Characteristics Engineering Data Electrical Durability Degree of protection IP67 10,000 Mechanical 10,000,000 operations min. 7,000 Durability 5,000 Electrical 500,000 operations min. 125 VAC cos=1 3,000 Operating speed 0.05 mm/s to 0.5 m/s *1 125 VAC cos=0.4 250 VAC cos=1 Mechanical 120 operations/min Operating 1,000 250 VAC cos=0.4 frequency Electrical 20 operations/min 700 500 Rated frequency 50/60 Hz 300 Insulation resistance 100 M min. (at 500 VDC) 15 m max. (initial value for the built-in Contact resistance 100 switch when tested alone) 70 50 Between terminals of the 1,000 VAC, 50/60 Hz for 1 min 30 Operating temperature: +202C same polarity Dielectric Operating humidity: 655%RH strength Between each terminal and Operating frequency: 20 operations/min 2,000 VAC, 50/60 Hz for 1 min non-current-carrying part 10 02 4 6 8 10 12 Rated insulation voltage (Ui) 1,000 VAC Switching Current (A) Pollution degree 3 (IEC947-5-1) Mechanical Durability (D4MC-5000) (operating environment) 10,000 Protection against electric shock Class II Operating temperature: +202C Operating humidity: 655%RH PTI (tracking characteristics) 175 No load 5,000 Operating frequency: 120 operations/min Switch category D (IEC335) Rated operating current (Ie) 10 A 2,000 Rated operating voltage (Ue) 250 VAC Vibration 1,000 Malfunction 10 to 55 Hz, 1.5-mm double amplitude *2 resistance 2 Destruction 1,000 m/s min. Shock 500 resistance 2 Malfunction 100 m/s min. *1 *2 Ambient operating temperature 10C to +80C (with no icing) 200 Ambient operating humidity 35% to 95%RH Weight Approx. 71 g (in case of panel mount plunger) 100 0.01 0.02 0.05 0.1 0.2 0.5 1 2 5 10 *1. Only for models with plungers. (Contact your OMRON representative for OT (mm) information on other models.) *2. Less than 1 ms under a free state at the operating limits. Structure and Nomenclature Structure Contact Form Roller Changing the Terminal Protective Cover around allows the cable to be pulled out (COM) 1 2 (NC) from either the right or the left. 4 (NO) Case M4 binding head screws (with toothed washers) are used as the terminal screws. Pushbutton Built-in switch Seal rubber Terminal Protective Cover Normally closed Common Normally open terminal (NC) terminal (COM) terminal (NO) 2 4 4 Durability (x 10 operations) Durability (x 10 operations)