Small Limit Switch D4V Compact Vertical Models Sized for Asian Standards Compact new design approximately 1/3 the size of OMRON vertical Limit Switches. Structure enables the terminal section to be fully opened for easy wiring. RoHS complaint. Degree of protection: IP65 Model Number Structure Model Number Legend D4V-81 Z 1 1. Actuator type 04: Roller lever 12: Roller plunger 07: Rod lever 22: Crossroller plunger 08: Adjustable roller lever 66: Coil spring 11: Push plunger 69: Wire spring Ordering Information List of Models Actuator type Model Roller lever D4V-8104Z Rod lever D4V-8107Z Adjustable roller lever D4V-8108Z Push plunger D4V-8111Z Roller plunger D4V-8112Z Crossroller plunger D4V-8122Z Coil spring D4V-8166Z Wire spring D4V-8169Z Note: Metallic roller levers and metallic variable roller levers can also be manufactured. Small Limit Switch D4V 1Specifications Certified Standards Characteristics Certification body Standard File No. Degree of protection IP65 CCC GB14048.5 Consult your OMRON Durability Mechanical 10,000,000 operations min. representative for (See note 3.) UL (See note.) UL508, Electrical 300,000 operations min. details. CSA C22.2 No. 14 (5 A at 250 VAC, resistive load) TV IEC60947-5-1 Operating speed 5 mm to 0.5 m/s Operating Mechanical 120 operations/min Note: Certification equivalent to CSA C22.2 No. 14 has been frequency Electrical 30 operations/min obtained from UL. Insulation resistance 100 M min. (at 500 VDC) Contact resistance 25 m max. (initial value) Ratings Dielectric Between 1,000 VAC, 50/60 Hz for 1 min Rated Non-inductive load (A) Inductive load (A) strength terminals of voltage the same Resistive load Lamp load Inductive load Motor load (V) polarity NC NO NC NO NC NO NC NO Between 1,500 VAC, 50/60 Hz for 1 min 125 VAC 5 1.5 0.7 3 2 1 current- 250 VAC 5 1 0.5 3 1.5 0.8 carrying 12 VDC 5 3 4 3 metal parts 24 VDC 5 3 4 3 and ground 125 VDC 0.4 0.2 --- --- --- 250 VDC 0.4 0.2 --- --- --- Rated insulation voltage 250 V (Ui) Note: 1. The above current ratings are for steady-state current. Pollution degree 3 (EN 60947-5-1) 2. Inductive load has a power factor of 0.4 min. (AC) and a time (application environment) constant of 7 ms max. (DC). Short-circuit protection 10-A fuse, gG or gI (IEC 269) 3. Lamp load has an inrush current of 10 times the steady- device state current. Conditional short-circuit 100 A (EN 60947-5-1) 4. Motor load has an inrush current of 6 times the steady-state current current. Rated open thermal 5 A (EN 60947-5-1) Inrush current NC 24 A max. current (lth) NO 12 A max. Electric shock protection Class I class Rated frequency 50/60 Hz Ratings for Safety Standard Vibration Malfunction 10 to 55 Hz, 1.5-mm double amplitude Certification resistance (See note 4.) 2 Shock Destruction 1,000 m/s (free position) min. CCC (GB14048.5), TV (EN60947-5-1) resistance 2 Malfunction 300 m/s (operation limit position) min. (See note 4.) Category and rating Ambient operating 20C to 60C (with no icing) AC-12: 250 VAC at 5 A, resistive load temperature range DC-12: 125 VDC at 0.4 A, resistive load Ambient operating 90% max. humidity range UL (UL508, CSA C22.2 No. 14) Weight Approx. 130 to 190 g Ratings Note: 1. The above values are initial values. 5 A, 250 VAC 2. The above characteristics may vary depending on the 0.4 A, 125 VDC model. Contact your OMRON representative for further details. 3. Durability values are calculated at an operating temperature of 5C to 35C, and an operating humidity of 40% to 70%. 4. Except for the coil spring model and wire spring model 2 Small Limit Switch D4V