Smart Slaves
Remote I/O Terminals with Transistors
DRT2-ID08(-1)/OD08(-1)/MD16(-1)
MIL Connector Terminals with Transistors
DRT2-ID16ML(-1)/OD16ML(-1)/ID16MLX(-1)/OD16MLX(-1)
Environment-resistive Terminals with Transistors (without detection functions)
DRT2-ID04CL(-1)/OD04CL(-1)/ID08CL(-1)/OD08CL(-1)/
MD16CL(-1)/HD16CL(-1)
Remote Maintenance
The lineup now includes a wide variety of Smart Slaves with different numbers of control
points that contribute to production site servicing and repair.
Printed on 100%
Recycled Paper
Note: Do not use this document to operate the Unit.
OMRON ELECTRONICS LLC
OMRON Corporation
Authorized Distributor:
1 East Commerce Drive, Schaumburg,
Industrial Automation Company
IL 60173 U.S.A.
Control Devices Division H.Q.
Tel:(1)847-843-7900/Fax:(1)847-843-8568
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
OMRON ASIA PACIFIC PTE. LTD.
Tel:(81)75-344-7109
83 Clemenceau Avenue,
Fax:(81)75-344-7149
#11-01, UE Square,
Singapore 239920
Regional Headquarters
Tel:(65)6835-3011/Fax:(65)6835-2711
OMRON EUROPE B.V.
OMRON (CHINA) CO., LTD.
Wegalaan 67-69, NL-2132 JD Hoofddorp
Room 2211, Bank of China Tower,
The Netherlands
200 Yin Cheng Zhong Road,
Tel:(31)2356-81-300/
PuDong New Area, Shanghai, 200120 China
Fax:(31)2356-81-388
Tel:(86)21-5037-2222/Fax:(86)21-5037-2200
Note: Specifications subject to change without notice. Cat. No. R110-E1-05
Printed in Japan
1006-0.3MUse production site information in a variety of applications,
Control System Maintenance System
Control System Maintenance System
such as maintenance and quality control.
DeviceNet
OMRON's DRT2-series Smart Slaves do not just input and output ON/OFF signals. They collect a variety
Configurator
Operating time monitor
of value-added information to help increase the rate of operation without changing the wiring for
Contact operation counter
Preventive maintenance
existing DeviceNet networks. In particular, they allow the separation of control systems and
of equipment
maintenance systems so that maintenance systems can be created independently of control systems.
Unit conduction time monitor
Slave and connected component comments
Control System Maintenance System
Control System Maintenance System
I/O power status monitor
Reduced startup time
Ethernet
Reliable equipment
Network power voltage monitor
startup
Reduced downtime Communication error history
PLC
Easy-to-view
PLC
monitor
Maintenance information
Maintenance is
Display
2
required for
Configurator
cylinder 23A in
What is the
inspection line A! It's time for
Unit conduction
present Network power
motor
time monitor
voltage monitor
communications
Control
maintenance!
(See note.)
voltage?
information
Control I/O
Operating time, contact operation
counter
DRT2-series
Smart Slave
Maintenance information
The wiring to
The cylinder's It might be time Is the I/O What was the
the I/O device is
speed is for a switch power supply cause
short-circuited
incorrect! inspection! turned ON? of the error?
or broken!
External load Operating time Contact operation I/O power status Communication error
DRT2-series
short-circuit detection monitor counter (See note.) monitor history monitor
Smart Slave
Machine Operation Faster Maintenance
Note: The contact operation counter function and the unit conduction time monitor function cannot be used simultaneously.
Work
Monitored by Slave
3
1
The Slave can hold comments, allowing
quick identification of fault locations and
Using OMRON Temperature Input Terminals for
faulty devices.
Pneumatic valve
Maintenance
(Connected device
comment)
Sensor
(Connected device Failure Prediction
comment)
The operating time of a preset temperature range is counted in 1-s units.
Measuring Counting
and Maintenance
The Slave Unit represents By counting the number of
machine operating time and ON/OFF operations and the
Slaves can notify the
operational changes as data, total operating time, the Slave Master when a setting
If prolonging the
Indicator service
enabling monitoring without Unit can provide notification is exceeded.
time it takes to
life control
increasing the load between when maintenance is required.
reach a certain
Cylinder
controllers.
Operating time
temperature may
(Connected device comment)
degrade
equipment:
Input
Collect a variety of data from maintenance systems without
Semiconductor
Time
manufacturing equipment
influencing control systems and productivity.
The peaks or valleys of temperature inputs that change in a regular pattern
Information monitoring for
All data can be converted to electronic format and,
are counted to predict when devices operating with severe temperature
each Slave
by combining with an OMRON PLC (CS/CJ Series),
swings are due for maintenance.
checked directly from Ethernet or the Internet to
Short Startup
allow remote maintenance. Slaves internally
Scaling points for 0%
convert display values
and 100% are set from
the Configurator
to temperature input
If it takes too long
values so the Controller
to modify the
ladder program on program no longer has
the Master when a
to be modified to
Scaling performed
Temperature
inside the Slave
perform this task.
Sensor replaced by one
Sensor is replaced:
with a different input range
Slave comment
Status confirmation using the status icon
Operating time monitor error or contact
operation count monitor error
Unit conduction time monitor error
Communications power voltage monitor error
2 3
Temperature