Cable Amplifier Proximity Sensor
E2EC
CSM_E2EC_DS_E_9_2
Subminiature Sensors with
Long-distance Detection
Shielded Sensor Heads from 3-mm to M12 diameters that
can be embedded in metal.
Robotics cables provided as a standard feature
(DC 2-Wire Models).
Indicator provided in Amplifier cable for easy confirmation
of operation.
Power supply range of 5 to 24 VDC for DC 3-Wire Models.
Be sure to read Safety Precautions on
page 6.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Ordering Information
Sensors [Refer to Dimensions on page 7.]
DC 2-Wire Models
Model
Appearance Sensing distance Operation mode
NO NC
3 dia. E2EC-CR8D1 2M * E2EC-CR8D2 2M *
0.8 mm
Shielded
5.4 dia. E2EC-C1R5D1 2M * E2EC-C1R5D2 2M *
1.5 mm
8 dia. E2EC-C3D1 2M * E2EC-C3D2 2M *
3 mm
M12 E2EC-X4D1 2M * E2EC-X4D2 2M *
4 mm
* Models with different frequencies are also available. The model numbers are E2EC-@@@@5 (example: E2EC-CR8D15).
DC 3-Wire Models
Model
Appearance Sensing distance
Output configuration NO
3 dia. E2EC-CR5C1 2M *1 *2
0.5 mm
Shielded
NPN open-collector output
8 dia. E2EC-C2R5C1 2M *1 *2
2.5 mm
*1. Models with different frequencies are also available. The model numbers are E2EC-@@@@5 (example: E2EC-CR5D15).
*2. NC models are also available.
Accessories (Order Separately)
Mounting Bracket
The Mounting Bracket for the E2EC-C1R5D@ is not provided with the Sensor. Order a Mounting Bracket separately if required. [Refer to Dimensions on page 8.]
Appearance Model Applicable Sensors
Y92E-F5R4 E2EC-C1R5D@ (5.4-mm-dia. Sensor)
1E2EC
Ratings and Specifications
DC 2-Wire Models DC 3-Wire Models
Item Model E2EC-CR8D@ E2EC-C1R5D@ E2EC-C3D@ E2EC-X4D@ E2EC-CR5C1 E2EC-C2R5C1
Sensing distance 0.8 mm 15% 1.5 mm 10% 3 mm 10% 4 mm 10% 0.5 mm 15% 2.5 mm 10%
Set distance 0 to 0.56 mm 0 to 1.05 mm 0 to 2.1 mm 0 to 2.8 mm 0 to 0.3 mm 0 to 1.7 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 3.)
Standard sensing Iron,
Iron, 5 5 1 mm Iron, 8 8 1 mm Iron, 5 5 1 mm Iron, 8 8 1 mm
object 12 12 1 mm
Response frequency
1.5 kHz 1 kHz
*1
Power supply volt-
5 to 24 VDC (4.75 to 30 VDC),
age (operating volt- 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
ripple (p-p): 10% max.
age range)
Current
--- 10 mA max.
consumption
Leakage current 0.8 mA max. ---
Load NPN open-collector output,
5 to 100 mA
current 100 mA max. (30 VDC max.)
Control
output
Residual 1 V max. (Load current: 100 mA,
3 V max. (Load current: 100 mA, Cable length: 2 m)
voltage Cable length: 2 m)
D1 Models: Operation indicator (red), Setting indicator (green)
Indicators Detection indicator (red)
D2 Models: Operation indicator (red)
Operation mode D1 Models: NO NO
(with sensing object D2 Models: NC Refer to the timing charts under I/O
approaching) Refer to the timing charts under I/O Circuit Diagrams on page 5 for details. Circuit Diagrams on page 5 for details.
Protection circuits Load short-circuit protection, Surge suppressor Surge suppressor
Ambient
Operating/Storage: 25 to 70C (with no icing or condensation)*2
temperature range
Ambient
Operating/Storage: 35% to 95% (with no condensation)
humidity range
Temperature
20% max. of sensing distance at 23C in the temperature range of 25 to 70C
influence
5% max. of sensing distance at the
2.5% max. of sensing distance at rated voltage in the rated voltage 15%
Voltage influence rated voltage range in the voltage
range
range of 4.75 to 30 V
Insulation
50 M min. (at 500 VDC) between current-carrying parts and case
resistance
500 VAC for 1 min between current-
Dielectric strength 1,000 VAC for 1 min between current-carrying parts and case
carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
2
Destruction: 500 m/s 10 times each in
2
Shock resistance Destruction: 1,000 m/s 10 times each in X, Y, and Z directions
X, Y, and Z directions
IEC 60529 IP67,
Degree of protection IEC 60529 IP64
In-house standards: oil-resistant (For Sensor Head only)
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight
Approx. 45 g
(packed state)
Case Brass
Sensing
ABS
surface
Materials
Clamp- Brass
--- ---
ing nut (nickel-plated)
Toothed
--- Iron (zinc-plated) ---
washer
Accessories Amplifier Mounting Bracket, Instruction manual Instruction manual
*1. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. Incorrect operation may occur if there is a large temperature difference between the Sensor Head and the Amplifier Unit.
2