F502-EN2-04.book Seite 29 Dienstag, 26. Juli 2005 5:48 17
Cylindrical Proximity Sensor in Plastic Housing
E2F
High quality full body plastic housing for high water
proof requirements
Polyarylate housing for light chemical resistance
Applications
Detection of bottle caps
Warm water
cleaning
High humidity environment
Ordering Information
Sensors
Model
Model Sensing distance Output specifications
Operating status
NO NC
DC 3-wire NPN E2F-X1R5E1 E2F-X1R5E2
M8
1.5mm
AC 2-wire Models E2F-X1R5Y1 E2F-X1R5Y2
*1 *1
DC 3-wire NPN E2F-X2E1 E2F-X2E2
M12 2mm
Shielded
*1
*1
AC 2-wire Models E2F-X2Y1 E2F-X2Y2
*1 *1
DC 3-wire NPN E2F-X5E1 E2F-X5E2
M18
5mm
*1 *1
AC 2-wire Models E2F-X5Y1 E2F-X5Y2
*2 *2
*1
*1
DC 3-wire NPN E2F-X10E1 E2F-X10E2
M30
10mm
*1
*1
AC 2-wire Models E2F-X10Y1 E2F-X10Y2
*2
*2
*1. A different frequency type is available. (E2F-X@@5; e.g.E2F-X5E15)
*2. A short-circuit protection type is available. (E2F-X@Y@-53; e.g. E2F-X5Y1-53) Power supply voltage: 100 to 120 VAC
Accessories (Order Separately)
E2F D-29
E2FF502-EN2-04.book Seite 30 Dienstag, 26. Juli 2005 5:48 17
Rating/performance
Model
E2F-X1R5E@ E2F-X2E@ E2F-X5E@ E2F-X10E@
E2F-X1R5Y@ E2F-X2Y@ E2F-X5Y@ E2F-X10Y@
Item
Sensing distance 1.5 mm 10% 2 mm 10% 5 mm 10% 10 mm 10%
Setting distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm
Differential distance 10% max.
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing
Iron, 8 8 1 mm Iron, 12 12 1 mm Iron, 18 18 1 mm Iron, 30 30 1 mm
object
Response frequen- E models: 2 kHz, Y mod- E models: 1.5 kHz, Y mod- E models: 600 Hz, Y mod- E models: 400 Hz, Y mod-
cy*1 els: 25 Hz els: 25 Hz els: 25 Hz els: 25 Hz
Power supply(Oper- E models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
ating voltage range) Y models: 24 to 240 VAC (20 to 264 VAC)
Current consumption E models: 17 mA max.
Leakage current Y models: 1.7 mA at 200 VAC
Switch-
ing ca- E models: 200 mA max. Y models: 5 to 100 mA E models: 200 mA max. Y models: 5 to 300 mA
Control
pacity
output
Residual E models: 2 V max. (load current: 200 mA with cable length: 2 m)
voltage Y models: Refer to the Specifications
Indicator lamp E models: Detection indicator (red LED) Y models: Operation indicator (red LED)
Operating status
E1, Y1 models: ON
(with sensing object
E2, Y2 models: NC
approaching)
Protective circuits E models: Reverse connection protection, load short-circuit protection, surge absorber Y models: None
Ambient temperature Operating/Storage: -25 C to 70 C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH
Temperature influ-
A maximum fluctuation of 10% max. of sensing distance at 23 C in temperature range of -25 C and 70 C
ence
E models: 2.5% max. of sensing distance within a range of 15% of rated power supply voltage Y models: 1%
Voltage influence
max. of sensing distance within a range of 10% of rated power supply voltage
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Dielectric strength E models: 1,000 VAC, 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
2
Shock resistance Destruction: 1,000 m/s for 10 times each in X, Y, and Z directions
Protective structure IEC IP67
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed
Approx.40g Approx. 50 g Approx. 130 g Approx. 170 g
state)
Case
Polyarylate
Sensing
Material surface
Clamp-
Polyallylate resin
ing nut
Accessories Instruction manual
*1. The response frequencies are average values measured on condition that the distance between each sensing object is twice as large as the size of the sensing
object and the sensing distance set is half of the maximum sensing distance.
D-30 Inductive Sensors