Flat Proximity Sensor E2K-F CSM E2K-F DS E 5 1 Flat Capacitive Sensor with a Thickness of Only 10 mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only 10 mm thick.) Direct mounting onto a metallic surface is possible. Be sure to read Safety Precautions on page 3. Ordering Information Sensors Refer to Dimensions on page 4. Model/Operation mode Appearance Sensing distance Output configuration NO NC E2K-F10MC1 2M E2K-F10MC2 2M 10 mm DC 3-wire Flat NPN Unshielded E2K-F10MC1-A 2M E2K-F10MC2-A 2M 4 to 10 mm 1E2K-F Ratings and Specifications Item Model E2K-F10MC -A E2K-F10MC Sensing distance 4 to 10 mm (adjustable with 12-turn adjuster) 10 mm 10% Set distance 0 to 7.5 mm * Differential travel 15% max. of sensing distance Detectable object Conductors and dielectrics Standard sensing object Grounded metal plate: 50 50 1 mm Response frequency 100 Hz Power supply voltage (operating 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. voltage range) Current consumption 10 mA max. at 24 VDC Load current NPN open collector, 100 mA max. (at 30 VDC) Control output Residual voltage 1.5 V max. (Load current: 100 mA, Cable length: 2 m) Indicators Detection indicator (red) Operation mode (with sensing NO (Refer to the timing charts under I/O Circuit Diagrams on page 3 for details.) object approaching) Protection circuits Reverse polarity protection, Surge suppressor Ambient temperature range Operating/Storage: 10 to 55C (with no icing or condensation) Ambient humidity range Operating/Storage: 35% to 95% Operating/Storage: 35% to 95% Temperature influence 15% max. of sensing distance at 23C in the temperature range of 10 to 55C Voltage influence 2.5% max. of sensing distance at rated voltage at rated voltage 10% Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions 2 Shock resistance Destruction: 500 m/s 3 times each in X, Y, and Z directions Degree of protection IP64 (IEC) IP66 (IEC) Connection method Pre-wired Models (Standard cable length: 2 m) Weight (packed state) Approx. 35 g Case Materials Heat-resistant ABS Sensing surface Accessories Instruction manual * The value for the E2K-F10MC -A is when it is adjusted to 10 mm. Engineering Data (Typical) Sensing Area (Grounded Metal Plate) Influence of Sensing Object Size and Material 12 10 12 11 11 9 Grounded metal plate (t = 1) 10 10 8 Y 9 9 Y 7 X 8 8 X 6 Non-grounded 7 7 Left and metal plate (t = 10) right Up and 6 5 6 down 5 5 4 4 4 3 3 3 2 2 2 Glass (t = 10) Phenol (t = 10) 1 1 1 0 10 20 30 40 50 60 70 80 20 16 12 8 4 0 4 8 12 16 20 20 16 12 8 4 0 4 8 12 16 20 Distance Y Distance Y (mm) Side length of sensing object (mm) (mm) Sensing Head Sensing Head 2 Distance X (mm) Distance X (mm) Distance (mm)