Rectangular Proximity Sensor E2Q6 CSM E2Q6 DS E 1 1 Freely Change the Sensing Direction Change between any of five sensing directions: front or 90 up, down, left, or right. Four indicators show the operating status of the Sensor from many directions. For the most recent information on models that have been certified for Refer to Safety Precautions on page 4. safety standards, refer to your OMRON website. Ordering Information Sensors Refer to Dimensions on page 6 DC Models Model Shielded/ Sensing distance Connection method Operation mode Unshielded NPN output PNP output Shielded E2Q6-N20E3-H E2Q6-N20F3-H 20 mm Terminal block NO + NC Unshielded 30 mm E2Q6-N30ME3-H E2Q6-N30MF3-H Accessories (Sold Separately) Recommended Cable Gland (ST Type) (Manufactured by LAPP) Purchase a cable gland to maintain a water-resistant structure. Product number Color Screw size Applicable cable outer diameter ST-M20 1.5 Black M20 P1.5 7 to 13 dia. Dimensions (Unit: mm) 25 37 For details or to make purchases, contact your OMRON sales 17 9 representative. 27.6 13.4 Note: A seal packing is not included. Applicable seal packing GPM20 Note: Purchase a seal packing to maintain water resistance. 1E2Q6 Ratings and Specifications Shielding Shielded Unshielded Item Model E2Q6-N20 3-H E2Q6-N30M 3-H Sensing distance 20 mm 10% 30 mm 10% Set distance 0 to 16 mm 0 to 24 mm Differential travel 15% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data Detectable object (Reference Value) on page 3.) Standard sensing object Iron, 60 60 1 mm Iron, 90 90 1 mm Response frequency *1 150 Hz 100 Hz Power supply voltage (operating 10 to 30 VDC, including 10% ripple (p-p) voltage range) Current consumption 20 mA max. Load current 200 mA max. Control output Residual voltage 2 V max. (at 200 mA load current) Indicators Power indicator (green), detection indicator (yellow) Operation mode NO + NC Power supply reverse polarity protection, output reverse polarity protection, and load short-circuit Protection circuits protection Ambient temperature range Operating and storage: 25 to 70C (with no icing or condensation) Ambient humidity range Operating and storage: 35% to 95% (with no condensation) Temperature influence 15% max. of sensing distance at 23C in the temperature range of 25 to 70C 2% max. of sensing distance at 24 VDC in the range of 24 VDC 15% Voltage influence 2% max. of sensing distance at 12 VDC in the range of 12 VDC 15% Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, at 50/60 Hz for 1 min. between current-carrying parts and case Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude in X, Y, and Z directions 2 Shock resistance (destruction) 300 m/s 3 times each in six directions Degree of protection IEC IP67 *2 Connection method Terminal block Weight (packed state/Sensor only) Approx. 250 g/approx. 230 g Case Polyamide (PA) Materials Sensing surface Polyamide (PA) Terminal base Polyamide (PA) Accessories Instruction manual *1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. When the recommended cable gland is used. 2