Optical Communications Communications Units for E3X-DA-N-series Fiber Amplifiers E3X-DRT21/SRT21/CIF11 CSM E3X-DRT21 SRT21 CIF11 DS E 3 2 CompoBus/S DeviceNet RS-422 Three New Communications Communications Communications Communications Units for Fiber Amplifiers Unit Unit Unit E3X-DRT21 E3X-SRT21 E3X-CIF11 Note: Manufacture of the E3X-DA6-P will be discontinued in March 2017. Features Fibers Mobile Console RS422 Connecting a hand-held Mobile Console enables easy setting and monitoring. E39-TM1 Terminal-block Unit Using a Terminal-block Unit allows input from Basic Switches. Programmable Controller Reduced Wiring New connectors enable wiring and space reductions, as well as easier maintenance. Create the Required Number of Channels by Connecting Up To 16 Units (14 Units for CompoBus/S). Basic Switch Wiring-reduction Connector E3X-CN02 1E3X-DRT21/SRT21/CIF11 Ordering Information Communications Units Fiber Amplifier with Incident Level Monitoring Function*1, 2 Communications method Model Communications method Model DeviceNet E3X-DRT21 All communications methods E3X-DA6-P CompoBus/S E3X-SRT21 Wiring-reduction Connector*1 RS-422 E3X-CIF11 Communications method Model Terminal-block Unit --- E3X-CN02 Communications method Model *1. Order Fiber Amplifiers and Wiring-reduction Connectors as sets. *2. Manufacture of the E3X-DA6-P will be discontinued in March 2017. All communications methods E39-TM1 Ratings and Specifications Communications Units Item Model E3X-DRT21 E3X-SRT21 E3X-CIF11 Communications method DeviceNet CompoBus/S RS-422 *2 E3X-DA6 *3, E3X-DA8 *3, E3X-DAB6, E3X-DAB8, E3X-DAG6, E3X-DAG8 Connectable Fiber Amplifiers *1 E3X-DA6TW *3, E3X-DA8TW *3, E3X-DA6-P *3, E39-TM1 Number of connectable Fiber 16 max. 14 max. 16 max. Amplifiers 11.4 to 26.4 VDC Power supply voltage 11 to 25 VDC 14 to 26.4 VDC (12 VDC 5% to 24 VDC +10%) Internal current consumption *4 70 mA max. 30 mA max. 40 mA max. Ambient temperature Operating: 20 to 55C, Storage: 30 to 70C (with no icing or condensation) Ambient humidity 35% to 85% (with no condensation) Weight (packed state) Approx. 150 g Approx. 200 g *1. Connection is not supported for Pre-wired Amplifiers (e.g., E3X-DA11-N) and water-resistant Amplifiers (e.g., E3X-DA11V). *2. Connection is supported for products manufactured on or after the date shown below (indicated with the lot number). Connection is also supported for models with MADE IN JAPAN on the cover underlined. Lot No.1 8 6 0 1 Manufactured on 18 June 2001. Last two digits of the year of manufacture. Month of manufacture. October, November, and December are represented with X, Y, and Z respectively. Day of manufacture. *3. Manufacturing of the E3X-DA TW Series was discontinued at the end of March 2012. Manufacture of the E3X-DA6/DA8/DA6-P will be discontinued in March 2017. *4. Does not include the current supplied to the Fiber Amplifier. Terminal-block Unit Item Model E39-TM1 Power supply voltage*1 12 to 24 VDC 10%, ripple (p-p) 10% max. Sensor power supply 11 to 23 VDC (power supply voltage 1 V) *1. The power supply for the E39- Current consumption 40 mA max. + Sensor current consumption (total: 100 mA max.) TM1 is provided from the Communications Unit (order Response speed 1.2 ms max. separately). Use an E3X-CN02 Number of inputs 1 point (order separately) Connector. *2. When 4 or more Units are grouped Input signals NPN/PNP no-voltage input (contact and non-contact), switchable together, the current consumption Input operating configuration N.O./ N.C., switchable per Unit must not exceed 75 mA. When using together with the Indicators Input signal display (orange) E3X-DA-N Fiber Amplifiers, Operating: connect the E39-TM1 Units at the Groups of 1 to 3 Units: 25 to 55C (with no icing or condensation) end of the group. In this case, the upper limit for the Ambient temperature*2 Groups of 4 to 8 Units: 25 to 45C (with no icing or condensation) ambient temperature for the E3X- Groups of 9 to 16 Units: 25 to 40C (with no icing or condensation) DA-N Amplifiers is the rated upper Storage: 30 to 70C limit 5C. 2