Digital Fiber Amplifier Unit E3X-DA-S/MDA CSM E3X-DA-S MDA DS E 15 4 Advanced Fiber Amplifier Units Features a Power Tuning function that optimizes light reception at the press of a button. APC circuits to suppress LED aging degradation used with 4- element LEDs. 2-channel models achieve the thinnest* profile in the industry, at only 5 mm per channel. 2-channel models also offer AND/OR control output. The E3X-MDA0 with two channels supports an EtherCAT Sensor Communications Unit or CompoNet Sensor Communications Unit. * (Based on July 2012 OMRON investigation.) Note: Manufacture of the E3X-DA SE-S/DA -S/DA AT-S/ Be sure to read Safety Precautions on DA RM-S/DA TW-S will be discontinued in March 2017. page 15. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Features Models available for a wide variety of applications at manufacturing sites Industry Leading Two Amplifiers Loaded in a Small Body 2-channel models Two amplifiers are loaded in a 10 mm-wide body. Checking LCD substrates seating and alignment Space usability can be approximately doubled. In addition, approximately 40% of the energy can be saved. (compared to the value per channel of the former model) 2-channel models 20mm E3X-MDA 10mm Advanced Analog High-speed and High-resolution Analog Output Supports Wide Variety of Applications Output Models Analog Control Output High-speed and High Resolution The voltage in the range of 1 to 5 V is output according to the incident Detection modes can be switched in accordance with applications. level (digital display). Wide variety of applications is possible including High-speed response of 80 s (super-high-speed mode) supports the positioning control or difference detection with multiple levels. positioning controls that require high-speed control. Sheet Displacement ON/OFF Analog 1E3X-DA-S/MDA Ordering Information Fiber Amplifier Units Amplifier Units with Cables (2 m) Refer to Dimensions on page 17. Model Item Appearance Functions NPN output PNP output Single-function models --- E3X-DA11SE-S 2M * E3X-DA41SE-S 2M * Standard models E3X-DA11-S 2M * E3X-DA41-S 2M * Green LED E3X-DAG11-S 2M E3X-DAG41-S 2M Mark-detecting models Timer, Response speed change (multiple color light Blue LED E3X-DAB11-S 2M E3X-DAB41-S 2M sources) Infrared LED E3X-DAH11-S 2M E3X-DAH41-S 2M External-input models Remote setting, counter, differential operation E3X-DA11RM-S 2M * E3X-DA41RM-S 2M * Twin-output models Area output, self-diagnosis, differential operation E3X-DA11TW-S 2M * E3X-DA41TW-S 2M * Advanced models ATC function models ATC (Threshold value automatic correction) E3X-DA11AT-S 2M * E3X-DA41AT-S 2M * Analog output models Analog output models E3X-DA11AN-S 2M E3X-DA41AN-S 2M 2-channel models AND/OR output E3X-MDA11 2M E3X-MDA41 2M * Manufacture of the E3X-DA SE-S/DA -S/DA AT-S/DA RM-S/DA TW-S will be discontinued in March 2017. Amplifier Units with Wire-saving Connectors Refer to Dimensions on page 18. Model Item Appearance Functions NPN output PNP output Single-function models --- E3X-DA6SE-S *1 E3X-DA8SE-S *1 Standard models E3X-DA6-S *1,2 E3X-DA8-S *1,2 Green LED E3X-DAG6-S *2 E3X-DAG8-S *2 Mark-detecting models Timer, Response speed change (multiple color light Blue LED E3X-DAB6-S *2 E3X-DAB8-S *2 sources) Infrared LED E3X-DAH6-S *2 E3X-DAH8-S *2 External-input models Remote setting, counter, differential operation E3X-DA6RM-S *1,2 E3X-DA8RM-S *1,2 Advanced models Twin-output models Area output, self-diagnosis, differential operation E3X-DA6TW-S *1,2 E3X-DA8TW-S *1,2 ATC function models ATC (Threshold value automatic correction) E3X-DA6AT-S *1 E3X-DA8AT-S *1 2-channel models AND/OR output E3X-MDA6 *2E3X-MDA8 *2 *1. Manufacture of the E3X-DA SE-S/DA -S/DA AT-S/DA RM-S/DA TW-S will be discontinued in March 2017. *2. These models allow you to use an E3X-DRT21-S VER.3 Sensor Communications Unit. When using the E3X-DRT21-S VER.3, use an E3X-CN02 Connector without a Cable for the Wire-saving Connector. Amplifier Units with Connectors for EtherCAT or CompoNet Sensor Communications Units Refer to Dimensions on page 19. Applicable Sensor Item Appearance Functions Model Communications Unit E3X-ECT 2-channel model AND/OR output E3X-MDA0 E3X-CRT Ratings and Specifications Control output/input Functions Response Interfer- Differen- Type Light source ON/OFF Analog Power time Input Timer ence pre- tial detec- counter ATC output output tuning vention tion Single-function models 1 ms --- --- Only Red LED --- --- --- --- --- 50 s to main Standard models 4ms E3X-DA G-S Green LED Mark- 50 s to Only detecting 3X-DA B-S Blue LED --- --- --- --- --- 4ms main models E3X-DA H-S Infrared LED Twin-output 50 s to Only models 4ms main (1 line) --- External-input 80 s to --- Ad- Main + models 4ms vanced Red LED sub ATC function 130 s to models (2 lines) --- --- models 4ms 80 s to Only Analog output --- --- 4ms main (1 line) Main + main 130 s to 2-channel models Red LED (2 inde- --- --- --- --- --- 4ms pendent lines) 2