Temperature Sensor E52 (for M3 Screws) A Wide Variety of High-precision Temperature Sensors Ideal for the thermal input devices of Temperature Controllers. Select from a wide variety of Temperature Sensors according to the temperature to be measured, location, and environment. General-purpose, low-cost, and exclusive models are available. Refer to Safety Precautions for E5CC/E5EC Digital Temperature Controller Datasheet (H177). Ordering Information List of Models Tempera- Protective Classifi- Descrip- Element Conduc- Terminal Model and appearance ture range Class tubing ma- Page cation tion type tor type type (See note 3.) terial Sheathed platinum Exposed resis- 196C to 3-conduc- E52-P AY Pt100 B SUS316 lead 3 tance 450C tor system General- wires thermom- purpose eter Models Sheathed Non- Exposed E52-CA AY K (CA) thermo- 0C to 900C grounded 2 (0.75) ASTM316L lead 4 to 6 E52-IC AY J (IC) couple type wires Low-cost platinum resis- 50C to 3-conduc- E52-P6DY Pt100 B tance 250C tor system Exposed Low-cost thermom- SUS304 lead 8 Models eter wires Low-cost E52-CA1DY K (CA) Ground- thermo- 0C to 400C 2 (0.75) E52-IC1DY J (IC) ed type couple Silicone- covered E52-CA1DY- 0C to 300CK (CA) SUS304 Lead 40 wires Exposed Exclusive Crimping E52-CA1GTY K (CA) Ground- 0C to 300C 2 (0.75) --- lead 9 Models Terminal E52-IC1GTY J (IC) ed type wires Silicone- covered E52- 0C to 200CK (CA) --- Lead CA1GTY-14 wires Note: 1. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 2. The temperature range varies with the material, thickness, and construction of the protective tubing. 1E52 General-purpose Models The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Model Number Legend Platinum Resistance Thermometers E52- Y D= M 123 4 5 6 7 1. Element type 5. Diameter P: Pt100 3.2: 3.2-mm dia. (Protective tubing construction: Sheathed) 2. Protective tubing length (L) 4.8: 4.8-mm dia. (Protective tubing construction: Sheathed) Specify the length in centimeters within the following range: 6.4: 6.4-mm dia. (Protective tubing construction: Sheathed) Unit (cm) 6. Heat resistance Diameter (D) Length (L) Code Temperature range Lead type 3.2 7 to 100 20C to 70C --- Vinyl-covered Sleeve: 0C to 70C 4.8 10 to 600 0C to 180C Glass-wool-covered, ex- 6.4 13 to 1,300 NETU Sleeve: 0C to 100C ternally shielded 3. Terminal 7. Lead length (M) A: Exposed lead wires Specify the length in meters within the following range. 4. Terminal processing Range: 0.5 and 1 to 100 m Y: Forked crimped terminals for M3.5 Examples Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-P42AY D=4.8 NETU 10M Sheathed Platinum Resistance Thermometers Refer to Model Number Legend above for the Pt100. Specifications Element type Pt100 Class JIS class B Sheath material SUS316 Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia. Conductor type 3-conductor system Temperature range 196C to 450C (in dry air) Terminal shape Forked crimped terminals for M3.5 2