Digital Process Controller Series E5 K Advanced Process Digital Controllers with Fuzzy Logic Field configurable outputs, options 100 ms sampling (for analog input) Advanced PID, or fuzzy self-tuning Conforms to UL, CSA and CE standards Water-resistant front panel meets IP66/NEMA 4X Remote set point with optional event input board Set point ramp Serial communications available Front panel programming Heat only or heat/cool control Auxiliary outputs (SPST) standard two for E5AK/E5EK, one for E5CK 3-year warranty Ordering Information Order Control Output Boards and Option Boards separately below. Description DIN size Supply voltage Part number Standard model 1/4 DIN 100 to 240 VAC E5AK-AA2-500 (96 x 96 mm) Position-proportional model (See Note 3) 100 to 240 VAC E5AK-PRR2-500 Standard model 24 VAC/VDC E5AK-AA2-500 AC/DC24 Position-proportional model (See Note 3) 24 VAC/VDC E5AK-PRR2-500 AC/DC24 Standard model 1/8 DIN 100 to 240 VAC E5EK-AA2-500 (48 x 96 mm) Position-proportional model (See Note 3) 100 to 240 VAC E5EK-PRR2-500 Standard model 24 VAC/VDC E5EK-AA2-500 AC/DC24 Position-proportional model (See Note 3) 24 VAC/VDC E5EK-PRR2-500 AC/DC24 Standard model 1/16 DIN 100 to 240 VAC E5CK-AA1-500 (48 x 48 mm) Standard model 24 VAC/VDC E5CK-AA1-500 AC/DC24 Non-standard model with built-in quick auto-tune button 100 to 240 VAC E5CK-AA1-302 (See Nomenclature section for details) Note: 1. When using the heater burnout alarm function with a standard model, the Linear Output Module cannot be used for the control outputs (heat). The Digital Controller provides transfer outputs at 4 to 20 mA for the PV and other values and control outputs at 4 to 20 mA for the current outputs. 2. E5EK-PRR2/E5AK-PRR2 controllers are supplied with relay output. The relay output is not compatible with any other module. 3. Position-proportional models are intended for motorized values (not 4-20 mA modulating valves). These use two relays (open and close) which will turn a motor clockwise or counter-clockwise, thus opening or closing the valve. 93E5AK/E5CK/E5EK E5AK/E5CK/E5EK OPTIONAL OUTPUT BOARDS Description Specifications Compatible controller Max. quantity Part number Relay SPST, 5 A, 250 VAC E5AK/E5EK 2 E53-R SSR (solid state relay) 1 A, 75 to 250 VAC E5AK/E5EK 2 E53-S Voltage pulse NPN, 12 VDC E5AK/E5EK 2 E53-Q NPN, 24 VDC E5AK/E5EK 2 E53-Q3 PNP, 24 VDC E5AK/E5EK 2 E53-Q4 Linear current 4 to 20 mA E5AK/E5EK 2 E53-C3 0 to 20 mA E5AK/E5EK 2 E53-C3D Linear voltage 0 to 10 VDC E5AK/E5EK 2 E53-V34 0 to 5 VDC E5AK/E5EK 2 E53-V35 Relay/Relay SPST/SPST, 5 A, 250 VAC E5CK 1 E53-R4R4 Relay/Pulse SPST, 5 A/NPN, 24 VDC E5CK 1 E53-Q4R4 SPST, 5 A/PNP, 24 VDC E5CK 1 E53-Q4HR4 Relay/Linear current SPST, 5 A/4 to 20 mA E5CK 1 E53-C4R4 SPST, 5 A/0 to 20 mA E5CK 1 E53-C4DR4 Relay/Linear voltage SPST, 5 A/0 to 10 VDC E5CK 1 E53-V44R4 Pulse/Pulse NPN/NPN, 24 VDC E5CK 1 E53-Q4Q4 PNP/PNP, 24 VDC E5CK 1 E53-Q4HQ4H Computer communications RS-232C E5AK/E5EK 3/1 E53-AK01 RS-232C E5CK 1 E53-CK01 RS-422 E5AK/E5EK 3/1 E53-AK02 Computer communications RS-485 E5AK/E5EK 3/1 E53-AK03 E5CK 1 E53-CK03 Event input For remote set point E5AK/E5EK 3/1 E53-AKB For remote set point E5CK 1 E53-CKB Transfer output 4 to 20 mA E5AK/E5EK 3/1 E53-AKF 4 to 20 mA E5CK 1 E53-CKF Note: If the control period is less than 5 seconds, use an SSR (solid state relay) or pulse voltage output. ACCESSORIES (ORDER SEPARATELY) Description Specifications Compatible controller Max. quantity Part number Current transformer order 50 A load, 5.8 mm hole dia. E5AK/E5EK 1 E54-CT1 only if using heater 120 A load, 12 mm hole dia. E5AK/E5EK 1 E54-CT3 burnout alarm function Terminal cover (supplied Provides finger protection E5AK 1 E53-COV0809 with Standard models) from terminals (VDE0106 E5CK 1 E53-COV07 part 100) E5EK 1 E53-COV08 Software For setup and monitoring All 1 SYS-CONFIG V2.0 requires optional computer communications board 94