Digital Controllers E5AR CSM E5AR DS E 3 5 E5AR Digital Controllers offer high speed, high precision, and multiple I/O and use a 5- digit, 3-row LCD display for high visual clarity. A short sampling period of 50 ms enables use in applications re- quiring high-speed response. PV, SP, and MV data is displayed simultaneously in a 3-row, negative LCD display with a backlight. Multiloop control, cascade control, and proportional control are possible with a single Controller. When using models with CompoWay/F communications, initial settings can be downloaded and settings can be masked using Support Software (CX-Thermo version 4.0 or higher). Equipped with calculation functions as a standard (e.g., square For the most recent information on models that have been certified for root calculation and broken-line approximation). safety standards, refer to your OMRON website. DeviceNet Communications Data setting and monitoring can be performed without special Refer to Safety Precautions for All E5 R programming. Models. Refer to E5AR/E5ER Operation for operating procedures. Model Number Structure Note: When your order, specify the power supply voltage. Model Number Legend 5. Auxiliary Outputs E5AR- - Blank:None 1 234 5678 9 10 4: 4PST-NO relay outputs 1. Constant Values/Program T: 2 transistor outputs None: Constant value 6. Optional Function 1 2. Control Method Blank:None Blank:Standard or heating/cooling control 3: RS-485 communications P: Position proportional control 7. Optional Function 2 3. Output 1 Blank:None R: DPST-NO relay outputs D: 4 event inputs Q: Pulse voltage and pulse voltage/current outputs 8. Input 1 C: Current and current outputs B: Universal-input and 2 event inputs 4. Output 2 F: Universal-input and FB Blank:None W: Universal-input and universal-input R: Relay outputs 9. Input 2 Q: Pulse voltage and pulse voltage/current outputs Blank:None C: Current and current outputs W: Universal-input and universal-input 10.Communications Method Blank:None FLK: CompoWay/F DRT: DeviceNet Note: The above model number legend is intended as a functional description of models. Not all possible combinations of functions are available. Confirm model availability in Ordering Information when ordering. The CX-Thermo Support Software (version 4.0 or higher) can be used to easily set parameters in conversational form. Note: Be sure to read the precautions for correct use and other precautions in the following user s manual before using the Digital Controller. E5AR/E5ER Digital Controller Users Manual (Cat. No. Z182) E5AR/E5ER Digital Controller DeviceNet Communication Users Manual (Cat. No. H124) 1E5AR Ordering Information When your order, specify the power supply voltage. Digital Controllers Standard Controllers (100 to 240 VAC) Size Control type Control mode Outputs Optional functions Model (control/transfer) Auxiliary Event Serial outputs inputs communi- (SUB) cations 96 96 Basic control Single-loop standard control 2 points: Pulse volt- 4 2 No E5AR-Q4B mm (1 loop) Single-loop heating and cooling control age and Pulse volt- age/current 2 points: Current and E5AR-C4B Current 2 points: Pulse volt- RS-485 E5AR-Q43B-FLK age and Pulse volt- age/current 2 points: Current and E5AR-C43B-FLK Current 2 points: Pulse volt- 6 E5AR-Q43DB-FLK age and Pulse volt- age/current 2 points: Current and E5AR-C43DB-FLK Current 4 points: Pulse volt- E5AR-QC43DB-FLK age and Pulse volt- age/current and Current (2 points) 2-loop control 2-loop standard control 2 points: Pulse volt- 4 4 RS-485 E5AR-Q43DW-FLK Single-loop heating and cooling control age and Pulse volt- Single-loop cascade control age/current Single-loop control with remote SP 2 points: Current and E5AR-C43DW-FLK Single-loop proportional control Current 2-loop standard control 4 points: Pulse volt- E5AR-QQ43DW-FLK 2-loop heating and cooling control age (2 points) and Single-loop cascade control Pulse voltage/current Single-loop control with remote SP (2 points) Single-loop proportional control 4-loop control 4-loop standard control 4 points: Current out- 4 4 RS-485 E5AR-CC43DWW- 2-loop heating and cooling control put (4 points) FLK 4 points: Pulse volt- E5AR-QQ43DWW- age (2 points) and FLK Pulse voltage/current (2 points) Position-pro- Single-loop position-proportional control Relay output 4 4 No E5AR-PR4DF portional con- (See note.) (1 open, 1 close) trol Relay output RS-485 E5AR-PRQ43DF-FLK (1 loop) (1 open, 1 close) and 1 current (transfer) output Note: Can be switched between close control and floating control. 2