Indication method No indication Temperature Controller Control mode ON/OFF Proportional (P) Input Output Relay Input/ Thermo- K (CA) 0 to 200 E5C2-R20K E5C2-R40K E5C2 stan- couple Chromel 0 to 300 E5C2-R20K E5C2-R40K dard vs. alumel scale 0 to 400 E5C2-R20K E5C2-R40K CSM E5C2 DS E 7 A 1 (C) 0 to 600 E5C2-R20K E5C2-R40K 0 to 800 E5C2-R20K E5C2-R40K DIN-sized (48 x 48 mm) Temperature 0 to 1,000 E5C2-R20K --- Controller with Analog Setting 0 to 1,200 E5C2-R20K --- J (IC) 0 to 200 E5C2-R20J --- Compact, low-cost Temperature Controller. Iron vs. 0 to 300 E5C2-R20J --- constantan Incorporates proportional control and reset adjustment function. 0 to 400 E5C2-R20J --- Consecutive mounting possible using mounting adapter. Incorporates a plug-in socket, thus allows to DIN-track and flush mounting. Refer to Safety Precautions for All Temperature Controllers. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information Temperature Controllers Standard Models Indication method No indication Indication method No indication Control mode ON/OFF Control mode ON/OFF Input Output Relay Input Output Relay 0 to 200 E5C2-R20K E5C2-R20K-W Input/ Resis- Platinum 50 to 50 E5C2-R20P-D stan- tance resistance 0 to 300 E5C2-R20K E5C2-R20K-W 20 to 80 E5C2-R20P-D dard Ther- thermom- scale mome- eter Pt100 0 to 50 E5C2-R20P-D 0 to 400 E5C2-R20K -- (C) ter 0 to 100 E5C2-R20P-D K (CA) 0 to 600 E5C2-R20K -- 0 to 200 E5C2-R20P-D 0 to 800 E5C2-R20K E5C2-R20K-W Thermo- 0 to 300 E5C2-R20P-D couple 0 to 1000 E5C2-R20K E5C2-R20K-W 0 to 400 E5C2-R20P-D 0 to 1200 E5C2-R20K E5C2-R20K-W Ther- THE (re- 50 to 50 E5C2-R20G 0 to 200 E5C2-R20J E5C2-R20K-W mistor placeable 0 to 100 E5C2-R20G element) J (IC) 0 to 300 E5C2-R20J E5C2-R20K-W 50 to 150 E5C2-R20G 0 to 400 E5C2-R20J E5C2-R20K-W 100 to 200 E5C2-R20G Control mode Proportional 150 to 300 E5C2-R20G Input Output Relay 0 to 200 E5C2-R40K E5C2-R40K-W Accessories (Order Separately) 0 to 300 E5C2-R40K E5C2-R40K-W Accessories (Order Separately) 0 to 400 E5C2-R40K -- Protective Cover K (CA) 0 to 600 E5C2-R40K -- Sockets Type Model 0 to 800 E5C2-R40K -- Thermo- couple Hard Protective Cover Y92A-48B 0 to 1000 -- -- 0 to 1200 -- E5C2-R40K-W Sockets 0 to 200 -- E5C2-R40J-W Note: 1. No reset function is incorporated by any E5C2 model with J (IC) 0 to 300 -- E5C2-R40J-W Name Model ON/OFF control. 0 to 400 -- E5C2-R40J-W Front Connecting Socket P2CF-08 The reset function is used to correct offset for proportional Back Cocontrol. Ifnnecting there is an offset belo Socket w the set valueP3G-08, turn the reset adjustment clockwise. Front Connecting Socket with Finger Protection P2CF-08-E 2. A special Watertight Cover is used to achieve this degree of Protective Cover (for finger protection) Y92A-48G protection (IP66, NEMA4). Refer to Y92A- N.ndication method No indication Control mode ON/OFF Proportional (P) Input Output Relay Input/ Thermo- K (CA) 0 to 200 E5C2-R20K E5C2-R40K stan- couple Chromel 0 to 300 E5C2-R20K E5C2-R40K dard vs. alumel scale 0 to 400 E5C2-R20K E5C2-R40K (C) 0 to 600 E5C2-R20K E5C2-R40K 0 to 800 E5C2-R20K E5C2-R40K Model Number Structure 0 to 1,000 E5C2-R20K --- 0 to 1,200 E5C2-R20K --- J (IC) 0 to 200 E5C2-R20J --- Model Number Legend Iron vs. 0 to 300 E5C2-R20J --- constantan 0 to 400 E5C2-R20J --- 1. Control Outputs 3. Input Note: A functional explanation is provided here for illustration, but models are R: Relay K: K-type thermocouple not necessarily available for all 2. Control Method J: J-type thermocouple possible combinations. Refer to 20: ON-OFF control P-D: Platinum resistance thermometer Ordering Information when ordering. (Pt100) 40: Proportional control Examples G: Thermistor with replaceable ele- Relay control output, ON/OFF ment control, type-K thermocouple input: E5C2-R20K Relay control output, proportional control, thermocouple input: E5C2- R40P-D Model Number Structure E5C2 Model Number Legend E5C2- - 1 2 3 4 1. Control Outputs 3. Input Note: A functional explanation is provided here for illustration, but models are R: Relay K: K-type thermocouple not necessarily available for all 2. Control Method J: J-type thermocouple possible combinations. Refer to cation method No indication 20: ON-OFF control P-D: Platinum resistance thermometer Ordering Information when ordering. Control mode ON/OFF Proportional (Pt100) 40: Proportional control Examples (P) G: Thermistor with replaceable ele- Relay control output, ON/OFF Input Output Relay ment control, type-K thermocouple input: Input/ Thermo- K (CA) 0 to 200 E5C2-R20K E5C2-R40K 4. Temperature Scale E5C2-R20K stan- couple Chromel 0 to 300 E5C2-R20K E5C2-R40K dard vs. alumel Blank: Degrees C Relay control output, proportional scale 0 to 400 E5C2-R20K E5C2-R40K (C) W: Both Degrees C and Degrees F control, thermocouple input: E5C2- 0 to 600 E5C2-R20K E5C2-R40K R40P-D 0 to 800 E5C2-R20K E5C2-R40K 0 to 1,000 E5C2-R20K --- Temperature RangesTemperature Controllers 0 to 1,200 E5C2-R20K --- J (IC) 0 to 200 E5C2-R20J --- Input Thermocouple Resistance Thermometer Thermistor Iron vs. 0 to 300 E5C2-R20J --- K (CA) J (IC) Platinum resistance Thermistor constantan Chromel vs. alumel Iron vs. constantan thermometer Pt100 (replaceable element) 0 to 400 E5C2-R20J --- 1,200 Themistor nominal resistance 1,200 1,000 6 k 6 k 30 k 550 4 k Standard 1,000 (0C) (0C) (0C) (200C)(200C) 800 scale 800 600 (C) 600 400 400 400 400 300 300 300 300 300 200 200 200 150 200 200 50 80 50 100 50 100 100 100 150 0 00000 00 0 0 0 000 00 0 50 100 50 50 20 Indica- Minimum Setting tion Control scale division 5 10 10 20 20 25 25 5 10 10 2212 5 10 10 2 2 2 2 2 method method mode Output (C) Analog No ON/OFF Relay Model E5C2-R20K E5C2-R20J E5C2-R20P-D E5C2-R20G setting indi- Propor- E5C2-R40K --- --- --- --- cation tional Relay Model (P) N Specifications Ratings Characteristics Setting accuracy 2% FS max. Supply voltage 100 to 240 VAC 50/60 Hz Hysteresis Approx. 0.5% FS (fixed) Operating voltage 90% to 110% of rated supply voltage range Proportional band 3% FS (fixed) Control period Approx. 20 s Power Approx. 3.6 VA consumption Reset range 5 1% FS min. (See note 1.) Input Thermocouple (with sensor burnout detection Insulation 20 M min. (at 500 VDC) resistance circuit), platinum resistance thermometer, or thermistor with replaceable element Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between charged termi- nals and uncharged metallic parts Control method ON/OFF or proportional control Vibration Malfunction: 10 to 55 Hz, 0.15-mm single amplitude for Setting method Analog setting resistance 10 min each in X, Y, and Z directions Destruction: 16.7 Hz, 2-mm double amplitude for 2 hrs Indication No indication each in X, Y, and Z directions method 2 Shock resistance Malfunction: 147 m/s , 3 times each in 6 directions Control output Relay output: SPDT, 3 A at 250 VAC, resistive 2 Destruction: 294 m/s , 3 times each in 6 directions load (switching capacity: 330 VA) Life expectancy Electrical: 100,000 operations min. (3 A at 110 VAC, Ambient operat- 10C to 55 C (with no icing or condensation) resistive load) ing temperature Weight Approx. 100 g (with flush-mounting adapter) Ambient operat- 45% to 85% Degree of protection Front panel: IEC standard IP40 (See note 2.) ing humidity Terminals: IEC standard IP00 Applicable Socket P2CF-08 (order separately), Note: Do not use an inverter output as the power supply. (Refer to P3G-08 (order separately) Safety Precautions for All Temperature Controllers.) Applicable Protec- Y92A-48B (order separately) tive Cover Note: 1. No reset function is incorporated by any E5C2 model with ON/OFF control. The reset function is used to correct offset for proportional control. If there is an offset below the set value, turn the reset adjustment clockwise. 2. A special Watertight Cover is used to achieve this degree of protection (IP66, NEMA4). Refer to Y92A- N. 2