Temperature Controllers E5CSV Easy Setting Using DIP Switch and Simple Functions in DIN 48 48 mm-size Temperature Controllers Easy setting using DIP and rotary switches. Models with two alarms added to Series, ideal for temperature alarm applications. Multi-input (thermocouple/platinum resistance thermometer) models also available. Clearly visible digital display with character height of 13.5 mm. Models available with black or white cases. RoHS compliant. Model Number Structure Model Number Legend Models with Terminal Blocks E5CSV- - 1 2 3 4 5 1. Output type 3. Input type 4. Power supply voltage R: Relay KJ: Thermocouple Blank: 100 to 240 VAC Q: Voltage for driving SSR P: Platinum resistance thermometer D: 24 VAC/VDC 2. Number of alarms T: Thermocouple/platinum resistance 5. Case color thermometer (multi-input) Blank: No alarm Blank: Black 1: 1 alarm W: Light gray 2: 2 alarms Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations. Refer to Ordering Information when ordering. Examples Relay control output, without alarm, thermocouple input, light gray case: E5CSV-RKJ-W Relay control output, one alarm output, multi-input, black case: E5CSV-R1T Temperature Controllers E5CSV 1Ordering Information List of Models Size Power supply Number of Control output TC/Pt multi-input TC input Pt input voltage alarm points Case color: Black Case color: Light gray Case color: Light gray 1/16 DIN 100 to 240 VAC 0 Relay E5CSV-RT --- --- 48 48 78 mm Voltage (for driving SSR) E5CSV-QT --- --- (W H D) 1 Relay E5CSV-R1T E5CSV-R1KJ-W E5CSV-R1P-W Voltage (for driving SSR) E5CSV-Q1T E5CSV-Q1KJ-W E5CSV-Q1P-W 2 (See note.) Relay E5CSV-R2T --- --- Voltage (for driving SSR) E5CSV-Q2T --- --- 24 VAC/VDC 0 Relay E5CSV-RTD --- --- Voltage (for driving SSR) E5CSV-QTD --- --- 1 Relay E5CSV-R1TD --- --- Voltage (for driving SSR) E5CSV-Q1TD --- --- 2 (See note.) Relay E5CSV-R2TD --- --- Voltage (for driving SSR) E5CSV-Q2TD --- --- Note: Models with two alarm outputs always use the upper limit alarm mode for the alarm 2 output. Accessories (Order Separately) Protective Cover Type Model Hard Protective Cover Y92A-48B Terminal Cover Model E53-COV10 Specifications Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC/VDC, 50/60 Hz Operating voltage range 85% to 110% of rated supply voltage Power consumption 5 VA 3 VA/2 W Sensor input Thermocouple input type: K, J, L Platinum resistance thermometer input type: Pt100, JPt100 Multi-input (thermocouple/platinum resistance thermometer) type: K, J, L, T, U, N, R, Pt100, JPt100 Control Relay output SPST-NO, 250 VAC, 3A (resistive load) output Voltage output (for driving the SSR) 12 VDC, 21 mA (with short-circuit protection circuit) Control method ON/OFF or 2-PID (with auto-tuning) Alarm output SPST-NO, 250 VAC, 1A (resistive load) Setting method Digital setting using front panel keys Indication method 3.5 digit, 7-segment digital display (character height: 13.5 mm) and deviation indicators Other functions Setting change prohibit (key protection) Input shift Temperature unit change (C/F) Direct/reverse operation Temperature range, Sensor switching (K/J/L, Pt100/JPt100) Switching is performed between a thermocouple and platinum resistance thermometer for multi-input models. Control period switching 8-mode alarm output Sensor error detection Ambient temperature 10 to 55C (with no condensation or icing) Ambient humidity 25% to 85% Storage temperature 25 to 65C (with no condensation or icing) 2 Temperature Controllers E5CSV