Basic-type Digital Temperature Controller (48 x 24 mm) E5GN CSM E5GN DS E 7 5 New 48 x 24-mm Basic Temperature Controller with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive Maintenance Function. Indication Accuracy Thermocouple input: 0.3% of PV (previous models: 0.5%) Pt input: 0.2% of PV (previous models: 0.5%) Analog input: 0.2% FS (previous models: 0.5%) E5GN E5GN-- -C Models with Screw Terminal Models with Screwless Clamp Models are available with screw terminal blocks or screwless Blocks Terminal Blocks 48 24 mm 48 24 mm clamp terminal blocks. A PV/SV-status display function can be set to automatically alternate For the most recent information on models that have been certified for safety standards, refer to your OMRON website. between displaying the status of the Temperature Controller (auto/ manual, RUN/STOP, and alarms) and the PV or SV. Refer to Safety Precautions for E5 N/E5 N-H. Preventive maintenance for relays in the Temperature Controller using a Control Output ON/OFF Counter. Refer to Operation for E5 N/E5 N-H for operating procedures. Switch the PV display between three colors. Compatible with Support Software (CX-Thermo version 4.2 or higher). Eleven-segment displays. Models are available with one or two alarm outputs. Main I/O Functions Event Inputs E5GN None Two Dual Display: PV and SV 4-digit Display Sensor Inputs Auto/manual switching Universal thermocouple/Pt inputs Auxiliary Outputs Temperature Controller status display (Models with temperature inputs) None Simple program function Analog current/voltage inputs One Control output ON/OFF count alarm (Models with analog inputs) Two PV change rate alarm Models also available with RS-232C Indication Accuracy communications Thermocouple input: 0.3% of PV Models also available with RS-485 Pt input: 0.2% of PV communications Control Output 1 Analog input: 0.2% FS Relay output Voltage output (for driving SSR) Sampling Period Current output 250 ms This datasheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User s Manual Basic Type (Cat. No. H156) E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158) 1E5GN Lineup 0, 1, or 2 auxiliary 1 control output Temperature input outputs Screw terminal block 0, 1, or 2 auxiliary Analog input 1 control output outputs E5GN Basic Type 0, 1, or 2 auxiliary Temperature input 1 control output outputs Screwless clamp terminal block 0, 1, or 2 auxiliary 1 control output Analog input outputs Note: Models with one control output and one or two auxiliary outputs can be used for heating/cooling control. Model Number Structure Model Number Legend Controllers 4. Input Type T: Universal thermocouple/platinum resistance thermometer input E5GN- - - - L: Analog current/voltage input 1 2 3 4 5 6 7 8 5. Power Supply Voltage 1. Control Output 1 Blank: 100 to 240 VAC R: Relay output D: 24 VAC/VDC Q: Voltage output (for driving SSR) C: Linear current output 6. Terminal Type Blank: Models with screw terminal block 2. Auxiliary Outputs C: Models with screwless clamp terminal block Blank: None 1: One output 7. Case Color 2: Two outputs Blank: Black 3. Option 8. Communications Protocol Blank: None Blank: None 01: RS-232C communications FLK: CompoWay/F communications 03: RS-485 communications B: Two event inputs H: Heater burnout/Heater short/Heater overcurrent detection (CT1) Note: 1. Models cannot be made for all combinations of options that are possible in the model number legend. Confirm model availability in Ordering Information before ordering. 2. Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details. * Auxiliary outputs are relay outputs that can be used to output alarms or processing results. 2