Digital Pressure Sensor
E8F2
CSM_E8F2_DS_E_4_3
Pressure Sensor with
Easy-to-Read LED Display
Pressure status can be checked at a glance from the
digital display and bar display.
Measurement pressure prevents incorrect outputs due
to momentary pressure changes. (*)
Perform automatic teaching simply by teaching pressure
values for good and bad products.
Industrys smallest models at just 28 28 29 mm.
* Only in hysteresis mode.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions
on page 6.
Ordering Information
Sensors (Refer to Dimensions on page 7.)
Model
Pressure range ON/OFF output Linear output
NPN output PNP output
0 to 100 kPa E8F2-A01C E8F2-A01B
Positive pressure
Open collector
0 to 1 MPa 1 to 5 V E8F2-B10C E8F2-B10B
(two independent outputs)
Negative pressure 0 to 101 kPa E8F2-AN0C E8F2-AN0B
Accessories (Order Separately) (Refer to Dimensions on page 7.)
Appearance Name Model Remarks
Mounting Bracket E89-F3 Provided with the E8F2.
Panel-mounting
E89-F4 Spacer provided.
Bracket
1E8F2
Ratings and Specifications
Sensor
NPN output E8F2-A01C E8F2-B10C E8F2-AN0C
Model
Item PNP output E8F2-A01B E8F2-B10B E8F2-AN0B
Power supply voltage 12 to 24 VDC10% with a ripple (p-p) of 10% max.
Current consumption 70 mA max. *1
Pressure type Gauge pressure
Rated pressure range 0 to 100 kPa 0 to 1 MPa 0 to 101 kPa
Pressure setting range 0 to 100 kPa 0 to 1 MPa 0 to 101 kPa
Withstand pressure 400 kPa 1.5 MPa 400 kPa
Applicable fluid Non-corrosive gas and non-flammable gas
Operating mode Hysteresis mode, window mode, and automatic teaching mode
Repeat accuracy
1%FS max.
(ON/OFF output)
Linearity (linear output) 1%FS max.
Response time (ON/OFF output) 5 ms max.
Linear output 1 to 5 V 5% F.S. with an output impedance of 1 k and a permissible resistive load of 500 k.
ON/OFF outputs NO or NC open collector (depending on whether the output configuration is NPN or PNP)
Load current 30 mA max.
Output applied voltage 30 VDC max.
NPN open collector output: 1 V max. with 30 mA load current
Residual voltage
PNP open collector output: 2 V max. with 30 mA load current
3.5-digit red LED
Green LED bar indicator
Display *2
The orange LED is lit for two independent outputs with output transistor turned ON.
Green unit indicator
Display accuracy 3%FS1 digit max.
Protection circuits Reverse polarity protection, load short-circuit protection
Operating: 0 to 55C
Ambient temperature range
Storage: 10 to 60C (with no icing)
Ambient humidity range Operating/Storage: 35% to 85% (with no condensation)
Temperature influence 3%FS max.
Voltage influence 1.5%FS max.
Insulation resistance 100 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC at 1 min
2
Destruction: 10 to 500 Hz, 1.0-mm double amplitude or 150 m/s , three times each for 11 min in the X, Y,
Vibration resistance
and Z directions
2
Shock resistance Destruction: 300 m/s 3 times each in the X, Y, and Z directions
Degree of protection IP50 (IEC)
Pressure port R (PT) 1/8 taper screw and M5 female screw
Connection method Pre-wired (standard length: 2 m)
Cable Approved by UL
Weight (packed state) Approx. 110 g
Pressure port Aluminum die-cast
Material
Case Heat-resistive ABS
Accessories Mounting Bracket, Instruction manual
*1. The current consumption is approximately 43 mA in energy-saving mode.
*2. Display Example of Digital Indicator
Setting unit
Model kPa
Applied pressure Digital display
E8F2-A01C 100 1000
E8F2-B10C 1000 1000
E8F2-AN0C 101 1 010
Note: The period ( ) in the display indicates the decimal point.
Its position will not change unless the setting unit is changed.
2