Modular Temperature Controller EJ1 CSM EJ1 DS E 12 4 In-panel Temperature Controller with Flexible Modular Design and Wide Integration with Host Devices The compact modular structure enables construction of temperature systems optimally suited to the application. Connection can be made to a Programmable Controller without any programming required, reducing the number of steps required in ladder programming design. One fully universal-input Unit includes a thermocouple, platinum-resistance thermometer, and analog input for easy selection and reduced inventory requirements. Connect directly to the G3ZA Multi-channel Power Controller using optimum cycle control for high-accuracy regulation with minimal noise. Supports DeviceNet Communications. Autotuning (AT) can be used for independent heating/cooling PID control. Self-tuning (ST) can be used to calculate the PID constants with the step Refer to the Safety Precautions on response method. page 20. Up to 16 Temperature Controllers can be connected to a single DeviceNet Communications Unit. Ordering Information Temperature Controller Standard Control Models Functions Power No. of Control Control Auxiliary Communications Heater Name supply control outputs outputs Input type Terminal Model Event output functions burnout voltage points 1 and 2 3 and 4 inputs alarm Basic Unit 24 VDC 2 Voltage Transistor None 2 *3 2 G3ZA connection Thermocouple, M3 terminal EJ1N-TC2A-QNHB (temperature supplied output: output: 2 points port: RS-485 platinum Screw-less control) *1 from the 2 points (sinking) From End Unit: resistance EJ1N-TC2B-QNHB clamp End Unit (for SSR Port A or port B: thermometer, V1.2 4 Voltage output: None None M3 terminal EJ1N-TC4A-QQ drive) *2 RS-485 analog 2 points (for voltage, and Screw-less SSR drive) *2 EJ1N-TC4B-QQ analog current clamp selectable for 2Current Transistor 2M3 terminal EJ1N-TC2A-CNB each channel. output: output: 2 points Screw-less 2 points (sinking) EJ1N-TC2B-CNB clamp HFU with None None None Transistor 4 Port C: RS-485 or No input M3 terminal EJ1N-HFUA-NFLK Programless output: RS-232C Screw-less Communications 4 points selectable. clamp *1 (sinking) EJ1N-HFUB-NFLK From End Unit: V1.2 Port A: RS-485 Port C: RS-422 M3 terminal EJ1N-HFUA-NFL2 Screw-less From End Unit: EJ1N-HFUB-NFL2 clamp Port A: RS-485 HFU with None None DeviceNet Screw-less DeviceNet communications clamp EJ1N-HFUB-DRT Communications *1 End Unit *1 24 VDC Transistor None Port A or B: RS- M3 terminal EJ1C-EDUA-NFLK output: 485 Detachable 2 points Connector: Port A EJ1C-EDUC-NFLK connector (sinking) *1. An End Unit is always required for connection to a Basic Unit or an HFU. An HFU cannot operate without a Basic Unit. External communications cannot be performed when using a Basic Unit only. *2. For heating/cooling control applications, control outputs 3 and 4 on the 2-point models are used for the cooling or heating control outputs. On the 4-point models, heating/cooling control is performed for the two input points. *3. When using the heater burnout alarm, purchase a Current Transformer (E54-CT1 or E54-CT3) separately. Note: Products for the EtherCAT master are also available. Ask your OMRON sales representative for details. Functional Upgrades Refer to page 17 for details. Upgrade functions are supported by the indicated version V1.1 orV1.2 ) or a higher version of the software. Refer to the following manual for precautionary information and other information necessary to use the EJ1: EJ1 Modular Temperature Controller Users Manual (Cat. No. H142) EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. 1EJ1 Accessories (Order Separately) Current Transformer (CT) CX-Thermo Support Software Ver. 4.1 Diameter Model Model 5.8 dia. E54-CT1 EST2-2C-MV4 12.0 dia. E54-CT3 USB-Serial Conversion Cable G3ZA Connecting Cable Model Cable length Model E58-CIFQ1 5 m EJ1C-CBLA050 Rail Mounting Equipment Name Model PFP-100N Mounting Rail PFP-50N Specifications Basic Unit/EJ1N-TC Ratings Item Type EJ1N-TC4 EJ1N-TC2 Power supply voltage 24 VDC Operating voltage range 85% to 110% of rated voltage Power consumption 5 W max. (at maximum load) 4 W max. (at maximum load) Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII ES1B Infrared Thermosensor: 10 to 70C, 60 to 120C, 115 to 165C, 140 to 260C Input * Analog input: 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 V Platinum resistance thermometer: Pt100, JPt100 Input impedance Current input: 150 max., voltage input: 1 M min. Voltage output Output voltage: 12 VDC 15%, max. load current: 21 mA (PNP models with short-circuit protection circuit) Transistor output --- Max. operating voltage: 30 V, max. load current: 100 mA Control Current output range: 4 to 20 mA or 0 to 20 mA DC outputs Load: 500 max. (including transfer output) Current output --- (Resolution: Approx. 2,800 for 4 to 20 mA DC, approx. 3,500 for 0 to 20 mA DC) Input points --- 2 Contact input --- ON: 1 k max., OFF: 100 k min. Event Non-contact ON: Residual voltage: 1.5 V max., inputs --- input OFF: Leakage current: 0.1 mA max. --- Outflow current: Approx. 4 mA per point Number of input and control Input points: 4, Control points: 4 Input points: 2, Control points: 2 points Setting method Via communications Control method ON/OFF control or 2-PID (with autotuning, self-tuning) V1.2 Two-point input shift, digital input filter, remote SP, SP ramp, manual manipulated variable, manipulated variable Other functions limiter, interference overshoot adjustment, loop burnout alarm, RUN/STOP, banks, I/O allocations, etc. Ambient temperature range Operating: 10C to 55C, Storage: 25C to 65C (with no icing or condensation) Ambient humidity range Operating: 25% to 85% (with no condensation) * Inputs are fully universal. Therefore, platinum resistance thermometer, thermocouple, infrared thermosensor, and analog input can be selected. 2