Connector Terminal Box (Muting Terminals) F39-TC5 CSM F39-TC5 DS E 4 1 As of August 2008 Significantly reduces amount of wiring between Safety Light Curtains and Muting Sensors. Provides IP67 protection against water and dust. Connection using connectors significantly reduces wiring work. The wiring status can be checked at a glance with the LED indicators. The Support Software can be connected, enabling on-site adjustment of a Light Curtain. Be sure to read the Safety Precautions on page 7 and the Precautions for All Safety Sensors . Ordering Information Connector Terminal Box Classification Applicable models Specification Type Model Model with Muting Sensor Output Mode F39-TC5P01 F3SJ-A P PNP F3SJ-B P Model with Override Mode F39-TC5P02 Muting Terminals Model with Muting Sensor Output Mode F39-TC5N01 F3SJ-A N NPN F3SJ-B N Model with Override Mode F39-TC5N02 Optional Accessories (Sold separately) Classification Appearance Model Short-circuit Connector F39-CN8 Waterproof Covers XS2Z-22 Note: One short-circuit connector is included with the F39-T 01 for Muting Sensors. Three waterproof covers are included with a Connector Terminal Box with Muting Sensor Output Mode (F39-TC5 01) and four waterproof covers with a Connector Terminal Box with Override Mode (F39-TC5 02). Order the above accessories only as spare parts. Specifications (Refer to Instruction Sheet for details.) Ratings Rated voltage 24 VDC 20% (at ambient temperature of 20C) Rated current Power line: 2.4 A, Signal line: 0.3 A Characteristics Contact resistance 40 m max. (connector section) Insulation resistance After applying 500 VDC for 60 s: 100 M min. Speed: 10 Hz to 500 Hz to 10 Hz in 20 minutes. 2 Simple vibration with full amplitude of 1.52 mm or 98 m/s (whichever has the smaller amplitude) for two Vibration resistance hours each in three directions X, Y, and Z (total of 6 hours). Measured while connector is connected. 2 490 m/s for 11 ms three times each along three axes, six directions X, Y, and Z (total of 18 times). Shock resistance Measured while connector is connected. (MIL-STD-202F Test 213B, Condition A) Ambient operating temperature 25 to 70C (with no icing or condensation) Ambient operating humidity 25% to 85% (with no icing or condensation) Degree of protection IP67 Accessories Short-circuit connector (models with Muting Sensor outputs only), waterproof cover 1F39-TC5 Connections Internal Circuit Diagrams PNP Model with Muting Sensor Output Mode F39-TC5P01 Note: When a short-circuit connector is connected to CN1, terminals 1 and 2, and terminals 3 and 4 will be short-circuited. CN2 (COMM) This connects the Muting Sensor input to Setting Console F39-MC21 muting input 1 and muting input 2 of the F3SJ. CN3 (L) CN4 (D) or CN1 PC Tool for F3SJ F39-GWUM F3SJ-A Emitter F3SJ-A Receiver Muting Sensor output 12 3 4567 8 12 341567 8 2 3412 3 45 (Brown) Power supply, 24 VDC (Pink) Test input (Purple) Reset input (White) Safety output 2 (Black) Safety output 1 (Gray) Auxiliary output 1 (Red) External device monitoring input (Blue) Power supply, 0 V 12 3 4 12 3412 3412 3 4 CN7 (MSA1) * CN8 (MSB1) * CN5 (MSA2) * CN6 (MSB2) * Muting Sensor A1 Muting Sensor B1 Muting Sensor A2 Muting Sensor B2 * Use the following connecting cable to connect the Muting Sensors: M12, 4-pin connector (Pin 1: +24 V, Pin 2: Not used, Pin 3: 0 V, Pin 4: Output) When using a Through-beam Photoelectric Sensor, use an XS2R-D426- 11-F Y-joint with Socket and Plug or similar product to connect the transmitter and receiver. Model with Override Mode F39-TC5P02 CN2 (COMM) Setting Console F39-MC21 CN3 (L) CN4 (D) or CN1 F3SJ-A Emitter F3SJ-A Receiver PC Tool for F3SJ F39-GWUM I/O auxiliary terminals 12 3 4567 8 12 341567 8 2 3412 3 45 (Brown) Power supply, 24 VDC (Pink) Test input (Purple) Reset input (White) Safety output 2 (Black) Safety output 1 (Gray) Auxiliary output 1 (Red) External device monitoring input (Blue) Power supply, 0 V 12 3 4 12 3412 3412 3 4 CN7 (MSA1) * CN8 (MSB1) * CN5 (MSA2) * CN6 (MSB2) * Muting Sensor A1 Muting Sensor B1 Muting Sensor A2 Muting Sensor B2 * Use the following connecting cable to connect the Muting Sensors: M12, 4-pin connector (Pin 1: +24 V, Pin 2: Not used, Pin 3: 0 V, Pin 4: Output) When using a Through-beam Photoelectric Sensor, use an XS2R-D426- 11-F Y-joint with Socket and Plug or similar product to connect the transmitter and receiver. 2