General-purpose Relay G2R- -S CSM G2R- -S DS E 2 1 Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with a coil-disconnection self-diagnostic function (LED type). High switching power (1-pole: 10 A). Environment-friendly (Cd, Pb free). Wide range of Sockets also available. LR Model Number Structure Model Number Legend G2R - - - 12 34 56 7 1. Relay Function 5. Terminals Blank: General-purpose S: Plug-in 2. Number of Poles 6. Classification 1: 1 pole Blank: General-purpose 2: 2 poles N: LED indicator D: Diode 3. Contact Form ND: LED indicator and diode Blank: SPDT NI: LED indicator with test button 4. Contact Type NDI: LED indicator and diode with test button Blank: Single 7. Rated Coil Voltage Ordering Information List of Models Contact form Enclosure Classification Coil ratings rating SPDT DPDT General-purpose G2R-1-S G2R-2-S LED indicator AC/DC G2R-1-SN G2R-2-SN LED indicator with test button G2R-1-SNI G2R-2-SNI Plug-in terminal Unsealed Diode G2R-1-SD G2R-2-SD LED indicator and diode DC G2R-1-SND G2R-2-SND LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI Note: When ordering, add the rated coil voltage and(S to the model number. Rated coil voltages are given in the coil ratings table. Example: G2R-1-S 12 VDC (S) New model Rated coil voltage 1G2R- -S Accessories (Order Separately) Connecting Sockets Track/surface-mounting Socket Back-mounting Socket Applicable Relay model Screwless clamp terminal Screw terminal Terminals Model P2RF-05S (See note.) PCB terminals P2R-05P, P2R-057P 1 pole P2RF-05-E + G2R-1-S(N)(D)(ND)(NI)(NDI) P2RF-05 Solder terminals P2R-05A (P2CM-S (option)) P2RF-08S (See note.) PCB terminals P2R-08P, P2R-087P 2 poles P2RF-08-E + G2R-2-S(N)(D)(ND)(NI)(NDI) P2RF-08 Solder terminals P2R-08A (P2CM-S (option)) Note: Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting. Accessories for Screwless Clamp Terminal Socket (Option) Name Model Clip & Release Lever P2CM-S Nameplate R99-11 Nameplate for MY Socket Bridge P2RM-SR (for AC), P2RM-SB (for DC) Mounting Tracks Applicable Socket Description Model 50 cm (l) x 7.3 mm (t): PFP-50N Mounting track 1 m (l) x 7.3 mm (t): PFP-100N 1 m (l) x 16 mm (t): PFP-100N2 Track-connecting Socket End plate PFP-M Spacer PFP-S Back-connecting Socket Mounting plate P2R-P* * Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side. Specifications Coil Ratings Must Must Coil inductance (H) Max. Rated current* operate release Power (ref. value) voltage Coil voltage voltage Rated voltage consumption resistance* (approx.) Armature Armature 50 Hz 60 Hz % of rated voltage OFF ON 24 V 43.5 mA 37.4 mA 253 0.81 1.55 110 V 9.5 mA 8.2 mA 5,566 13.33 26.83 AC 120 V 8.6 mA 7.5 mA 7,286 16.13 32.46 80% max. 30% max. 110% 0.9 VA at 60 Hz 230 V 4.4 mA 3.8 mA 27,172 72.68 143.90 240 V 3.7 mA 3.2 mA 30,360 90.58 182.34 Must Must Coil inductance (H) Max. operate release Power (ref. value) voltage Coil voltage voltage Rated voltage Rated current* consumption resistance* (approx.) Armature Armature % of rated voltage OFF ON 6 V 87.0 mA 69 0.25 0.48 12 V 43.2 mA 278 0.98 2.35 DC 70% max. 15% min. 110% 0.53 W 24 V 21.6 mA 1,113 3.60 8.25 48 V 11.4 mA 4,220 15.2 29.82 * The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of 10%. 2