G2RL PCB Power Relay Low Profile Power Relay with 15.7 mm height, ideal for incorporation in miniature equipments A wide variety of single pole, double pole and high-capacity type Relays are available. High sensitivity with power consumption of 400 mW. Offers high insulation with insulation distance above 8 mm and impulse withstand voltage of 10kV between coil and contacts. Satisfies ambient operating temperature requirement of 85C. Standard model conforms to VDE standards. RoHS Compliant Model Number Legend Application Examples 1. Number of 2. Contact 3. Enclosure rating 4. Classification Home appliances G2RL- - Poles Form None : Flux protection None : Standard OA equipments 12 3 4 1: 1-pole None : NO/NC 4 : Fully sealed E : High-capacity G Industrial machinery 2: 2-pole A: NO 2 R L Ordering Information Classification Contact form Terminal Shape Enclosure rating Model Rated coil voltage Minimum packing unit Flux protection G2RL-1A SPST-NO (1a) Fully sealed G2RL-1A4 Flux protection G2RL-1 SPDT (1c) Fully sealed G2RL-14 Standard Flux protection G2RL-2A 5 VDC DPST-NO (2a) Fully sealed G2RL-2A4 12 VDC PCB terminals 20 pcs/tube 24 VDC Flux protection G2RL-2 DPDT (2c) 48 VDC Fully sealed G2RL-24 Flux protection G2RL-1A-E SPST-NO (1a) Fully sealed G2RL-1A4-E High-capacity Flux protection G2RL-1-E SPDT (1c) Fully sealed G2RL-14-E Note 1. When ordering, add the rated coil voltage to the model number. Example: G2RL-1A 5 VDC Rated coil voltage Note 2. Place your order in tube (20 pcs/tube) units. Note 3. Contact your OMRON sales representative for fully sealed models. Ratings Coil Item Must operate voltage Must release voltage Max. voltage Rated current Coil resistance Power consumption (V) (V) (V) (mA) () (mW) Rated voltage % of rated voltage 5 VDC 80.0 62.5 12 VDC 33.3 360 130% Approx. 400 75% max. 10% min. 24 VDC 16.7 1,440 (at 85C) 48 VDC 8.96 5,358 Approx. 430 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The Max. voltage is the maximum voltage that can be applied to the relay coil. Contacts Classification General-purpose Models (resistive load) High-capacity Models (resistive load) Item Model G2RL-1A G2RL-1 G2RL-2A G2RL-2 G2RL-1A-E G2RL-1-E Contact type Single Contact material Ag-alloy (Cd free) 12 A at 250 VAC 8 A at 250 VAC 16 A at 250 VAC Rated load 12 A at 24 VDC (See note) 8 A at 30 VDC (See note) 16 A at 24 VDC (See note) Rated carry current 12 A (See note) 8 A (70C)/5 A (85C) (See note) 16 A (See note) Max. switching voltage 440 VAC, 300 VDC Max. switching current 12 A 8 A 16 A Failure rate (P level) 40 mA at 24 VDC (reference value*) * This value was measured at a switching frequency of 120 operations/min. Note: Contact your OMRON representative for the ratings on fully sealed models. 1G2RL PCB Power Relay Characteristics Classification General-purpose Models High-capacity Models Item Number of poles 1-pole 2-pole 1-pole Contact resistance *1 100 m max. Operate (set) time 15 ms max. Release (reset) time 5 ms max. Max. Mechanical 18,000 operation/hr operating Electrical 1,800 operation/hr frequency Insulation resistance *2 1,000 M min. Between coil and 5,000 VAC, 50/60 Hz for 1min contacts Between contacts Dielectric of the same 1,000 VAC, 50/60 Hz for 1min strength polarity Between contacts 2,500 VAC, 50/60 Hz for 1min of different polarity Insulation Between coil and Clearance: 8 mm, Creepage: 8 mm distance contacts Impulse withstand voltage 10 kV (1.2 x 50 s) Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Vibration resistance Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 2 Destruction 1,000 m/s Shock 2 2 resistance Malfunction Energized: 100 m/s , De-energized: 100 m/s Mechanical 20,000,000 operations (at 18,000 operations/hr) Durability Electrical *3 G2RL-1(A): 50,000 operations at 250 VAC, 12 A G2RL-2(A): 30,000 operations at 250 VAC, 8 A G2RL-1(A)-E: 30,000 operations at 250 VAC, 16 A (resistive load) 30,000 operations at 24 VDC, 12 A 30,000 operations at 30 VDC, 8 A 30,000 operations at 24 VDC, 16 A G Ambient operating temperature -40C to 85C (with no icing or condensation) 2 Ambient operating humidity 5% to 85% (with no icing or condersation) R Weight Approx. 12 g L Note. Values in the above table are the initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method *2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. *3. 1,800 operations per hour. Engineering Data Maximum Switching Capacity G2RL-1A, G2RL-1 G2RL-1A-E, G2RL-1-E G2RL-2A, G2RL-2 50 50 50 AC resistive load AC resistive load AC resistive load 10 10 10 5 5 5 DC resistive DC resistive DC resistive load load load 1 1 1 0.5 0.5 0.5 0.1 0.1 0.1 0 5 10 20 30 50 100 500 1,000 0 5 10 20 30 50 100 500 1,000 0 5 10 20 30 50 100 500 1,000 Switching voltage (V) Switching voltage (V) Switching voltage (V) Ambient Temperature vs. Maximum Ambient Temperature vs. Must Coil Voltage Operate and Must Release Voltages 250 100 Sample: Must operate voltage G2RL-14-E 24 VDC 90 Must release voltage Number of relays: 5 pcs 200 80 max. X 180 70 min. 150 60 130 50 100 40 max. 30 X min. 50 20 10 0 10 20 30 40 50 60 70 80 85 90 100 0620 400 80 100 120 Ambient temperature (C) Ambient temperature (C) Note. The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. 2 Maximum coil voltage (%) Switching current (A) Must operate/must release voltage Switching current (A) (percentage of rated voltage) (%) Switching current (A)