G2RL-1A-E2-CV-HA PCB Power Relay Compact single pole Relay for High Current Load Switching & G 2 High Ambient Temperature R L High current 23 A switching surpassing standard G2RL models. I E Meets ambient operating temperature requirements of 105C 2 Low profile 16.7 mm max. in height. G Reinforced insulation between coil and contact with 10 kV Impulse voltage. 2 Conforms to EN60335-1 of Safety of Household appliances. R L Clearance and creepage distances: 8 mm / 8 mm min. I Coil insulation system: Class F (UL1446) 1 A RoHS Compliant I E 2 Model Number Legend Application Examples I C G2RL- - - - V Home appliances 123 4 5 6 I Cooking top, Microwave Oven H 1. Number of pole 4. Classification A Industrial use 1: 1 Pole E2: High-capacity at 23 A HVAC 5. Special Requirement 2. Contact Form CV: Ambient operating temperature 105C A: SPST-NO (1a) 3. Enclosure Rating 6. Market Code HA: Home Appliance according to IEC/EN60335-1 None: Flux protection Ordering Information Classification Contact form Enclosure rating Model Rated coil voltage Minimum packing unit 5 VDC High-capacity & SPST-NO (1a) Flux protection G2RL-1A-E2-CV-HA 12 VDC 100 pcs. / tray High-temperature 24 VDC Note: 1. When ordering, add the rated coil voltage to the model number. Example: G2RL-1A-E2-CV-HA DC5 Rated coil voltage However, the notation of the coil voltage on the product case will be marked as VDC. Note: 2. Place your order in tray (100 pcs./tray) units. Ratings Coil Ratings Must-operate voltage Must-release voltage Item Max. voltage (V) Rated current Coil resistance Power consumption (V) (V) (mA) () (mW) Rated voltage % of rated voltage 5 VDC 80.0 62.5 130% 12 VDC 33.3 360 75% max. 10% min. Approx. 400 (at 23C) 24 VDC 16.7 1,440 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note: 2. The operating characteristics are measured at a coil temperature of 23C. Note: 3. The Max. voltage is the maximum voltage that can be applied to the relay coil. Contact Classification High-capacity & High-temperature type (resistive load) Item Model G2RL-1A-E2-CV-HA Contact type Single Contact material Ag-Alloy (Cd free) Rated load 23 A at 250 VAC Rated carry current 23 A Max. switching voltage 250 VAC Max. switching current 23 A 1G2RL-1A-E2-CV-HA PCB Power Relay Characteristics Classification High-capacity & High-temperature type Item Model G2RL-1A-E2-CV-HA Contact resistance *1 100 m max. Operate time 15 ms max. Release time 5 ms max. G 2 Insulation resistance *2 1,000 M min. R L Between coil and contacts 5,000 VAC, 50/60 Hz for 1 min I Dielectric strength Between contacts of the E 1,000 VAC, 50/60 Hz for 1 min 2 same polarity Impulse withstand voltage 10 kV (1.2 50 s) G Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Vibration resistance 2 Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) R 2 Destruction 1,000 m/s L Shock resistance 2 2 I Malfunction Energized: 100 m/s , De-energized: 100 m/s 1 Mechanical 20,000,000 operations (18,000 operation per hour) A Durability Electrical *3 100,000 operations at 250 VAC, 23 A, at 105C (1s ON / 9s OFF) I (resistive load) E Ambient operating temperature -40C to 105C (with no icing or condensation) 2 Ambient operating humidity 5% to 85% (with no icing or condensation) I C Weight Approx. 12 g V Note: Values in the above table are the initial values at 23C. I *1. Measurement conditions: 5 VDC, 1 A, voltage drop method H *2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. A *3. 360 operations per hour. Engineering Data Maximum Switching Capacity Ambient Temperature vs. Maximum Coil Voltage 25 200 23 180 20 150 130 15 100 10 50 5 0 0 0 50 100 150 200 250 300 020 23 40 60 80 100 105 120 Switching voltage (V) Ambient Temperature (C) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Shock Malfunction Ambient Temperature vs. Must Operate and Must Release Voltage Y 100 Test conditions: Shock is applied 1,000 Must operate voltage 90 in X, Y, and Z directions three Must release voltage times each with without energizing 80 max. the Relays to check the number of X X Z 70 min. malfunctions. 1,000 1,000 60 Requirement: None malfuction max. 2 50 100 m/s X 130 40 min. 30 20 1,000 1,000 Shock direction X Z 10 XX Y 0 Z 020 40 60 80 100 120 Z Ambient Temperature (C) 1,000 2 Unit: m/s Y Y 2 Switching current (A) Maximum coil voltage (% of rated) Maximum coil voltage (% of rated)