G2RL PCB Power Relay Low Profile Power Relay with 15.7 mm height, ideal for incorporation in miniature equipments A wide variety of single pole, double pole, high-capacity (16 A) type and high-sensitivity type (250 mW) Relays are available. Low profile 15.7 mm max. in height. Conforms to VDE (EN61810-1), UL508 and CSA22.2. IEC/EN 60335-1 conformed. (-HA Model) Satisfies ambient operating temperature requirement of 85C and 105C (-CV Model). Clearance and creepage distance: 8 mm / 8 mm min. Coil insulation system: Class F (UL1446). G2RL-1A-E-ASI: TV3 Rating models available. RoHS Compliant Model Number Legend Application Examples G 2 Home appliances G2RL- - - - - R OA equipments 1 2 3 4 5 6 7 L Industrial machinery 1. Number of poles 5. Special Requirement 1: 1 pole None : Standard 2: 2 pole CV : 16 A, pinning 5 mm,: switching at 105C 2. Contact Form 6. Market Code None : SPDT (1c) None : General purpose A : SPST-NO (1a) HA : Home Appliance according to IEC/EN60335-1 7. Contact material 3. Enclosure rating None : Standard (Ag-alloy, Cd free) None : Flux protection ASI : AgSnIn 4: Sealed 4. Classification None : Standard E : High-capacity H : High-sensitivity Ordering Information Terminal Shape Market Code Classification Contact form Enclosure rating Model Rated coil voltage Minimum packing unit Flux protection G2RL-1A SPST-NO (1a) Sealed G2RL-1A4 Flux protection G2RL-1 SPDT (1c) Sealed G2RL-14 Standard Flux protection G2RL-2A DPST-NO (2a) 5 VDC Sealed G2RL-2A4 12 VDC Flux protection G2RL-2 24 VDC DPDT (2c) General Sealed G2RL-24 48 VDC purpose G2RL-1A-E Flux protection SPST-NO (1a) G2RL-1A-E-ASI PCB terminals 20 pcs/tube Sealed G2RL-1A4-E High-capacity Flux protection G2RL-1-E SPDT (1c) Sealed G2RL-14-E G2RL-1A-E-CV SPST-NO (1a) G2RL-1A-H High-sensitivity SPDT (1c) G2RL-1-H 12 VDC DPST-NO (2a) Flux protection G2RL-2A-HA 24 VDC Standard Home DPDT (2c) G2RL-2-HA Appliance SPST-NO (1a) G2RL-1A-E-HA High-capacity SPDT (1c) G2RL-1-E-HA Note 1. When ordering, add the rated coil voltage to the model number. Example: G2RL-1A DC5 Rated coil voltage However, the notation of the coil voltage on the product case will be marked as VDC. Note 2. Place your order in tube (20 pcs/tube) units. Note 3. Contact your OMRON sales representative for sealed models. 1G2RL PCB Power Relay Ratings Coil Item Must operate voltage Must release voltage Max. voltage Rated current Coil resistance Power consumption (V) (V) (V) (mA) () (mW) Rated voltage % of rated voltage 5 VDC 80.0 62.5 12 VDC 33.3 360 Approx. 400 Standard 70% max. 24 VDC 16.7 1,440 130% 10% min. 48 VDC 8.96 5,358 (at 85C) Approx. 430 12 VDC 20.8 576 High- 75% max. Approx. 250 sensitivity 24 VDC 10.42 2,304 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The Max. voltage is the maximum voltage that can be applied to the relay coil. Contacts Classification Standard type (resistive load) High-capacity type (resistive load) High-sensitivity type (resistive load) Item Model G2RL-1A G2RL-1 G2RL-2A G2RL-2 G2RL-1A-E (-CV, -ASI) G2RL-1-E G2RL-1A-H G2RL-1-H Contact type Single Contact material Ag-alloy (Cd free) 12 A at 250 VAC 8 A at 250 VAC 16 A at 250 VAC Rated load 10 A at 250 VAC (See note) 12 A at 24 VDC (See note) 8 A at 30 VDC (See note) 16 A at 24 VDC (See note) 8 A (70C)/5 A (85C) Rated carry current 12 A (See note) 16 A (See note) 10 A (See note) (See note) Max. switching voltage 440 VAC, 300 VDC G Max. switching current 12 A 8 A 16 A 10 A 2 R Failure rate (P level) 40 mA at 24 VDC L (reference value*) * This value was measured at a switching frequency of 120 operations/min. Note: Contact your OMRON representative for the ratings on sealed models. Characteristics Classification Standard type High-capacity type High-sensitivity type Item Number of poles 1-pole 2-pole 1-pole Contact resistance *1 100 m max. Operate (set) time 15 ms max. Release (reset) time 5 ms max. Insulation resistance *2 1,000 M min. Between coil and 5,000 VAC, 50/60 Hz for 1min contacts Between contacts Dielectric of the same 1,000 VAC, 50/60 Hz for 1min strength polarity Between contacts 2,500 VAC, 50/60 Hz for 1min of different polarity Impulse withstand voltage 10 kV (1.2 x 50 s) Vibration Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) resistance Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 2 Shock Destruction 1,000 m/s 2 2 resistance Malfunction Energized: 100 m/s , De-energized: 100 m/s Mechanical 20,000,000 operations (at 18,000 operations/hr) G2RL-1(A)-E, G2RL-1A-E-ASI: 30,000 operations at 250 VAC, 16 A G2RL-1(A): G2RL-2(A): Durability Electrical *3 30,000 operations at 24 VDC, 16 A G2RL-1(A)-H: 50,000 operations at 250 VAC, 12 A 30,000 operations at 250 VAC, 8 A (resistive load) G2RL-1A-E-CV: 50,000 operations at 250 VAC, 10 A 30,000 operations at 24 VDC, 12 A 30,000 operations at 30 VDC, 8 A 50,000 operations at 250 VAC, 16 A at 105C -40C to 85C (with no icing or condensation) Ambient operating temperature -40C to 105C (with no icing or condensation) by G2RL-1A-E-CV Ambient operating humidity 5% to 85% (with no icing or condensation) Weight Approx. 12 g Note. Values in the above table are the initial values at 23C. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method *2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. *3. 1,800 operations per hour. 2