Slim Relay G2RV The World s First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay condition. Slim outline to save space. Push-in terminals and accessories for easy wiring. Model Number Structure Model Number Legend G2RV-SL - 12 3 4 5 1. Auxiliary Type Designation 4. Relay Pushbutton SL: Slim relay and socket combination 0: Without pushbutton 2. Wire Connection 5. Input Voltage 7: Screw terminals 5: Push-in terminals 3. Relay LED 0: Without LED Note: LED indicator available on socket. Ordering Information List of Models Classification Enclosure rating Input voltage Type of connection Contact form SPDT Plug-in terminals General-purpose Unsealed AC/DC Screw terminals G2RV-SL700 Push-in terminals G2RV-SL500 Relay and Socket Combinations Input voltage Screw terminals Push-in terminals 12 VDC G2RV-SL700-12 VDC G2RV-SL500-12 VDC 24 VDC G2RV-SL700-24 VDC G2RV-SL500-24 VDC 24 VAC/DC G2RV-SL700-24 VAC/DC G2RV-SL500-24 VAC/DC 48 VAC/DC G2RV-SL700-48 VAC/DC G2RV-SL500-48 VAC/DC 110 VAC G2RV-SL700-110 VAC G2RV-SL500-110 VAC 230 VAC G2RV-SL700-230 VAC G2RV-SL500-230 VAC Slim Relay G2RV 1Specifications Input Ratings *1 Rated voltage Rated current Must operate Must release Power consumption Input voltage voltage voltage AC DC % of rated voltage AC (VA) DC (mW) % of rated voltage Approx. Approx. 50 Hz 60 Hz 12 VDC --- --- 27.2 mA 80% 10% --- 300 mW 10% 24 VDC --- --- 13.3 mA --- 300 mW 24 VAC/DC 21.1 mA 22.5 mA 13.0 mA 0.5 VA 300 mW 48 VAC/DC 8.5 mA 9.0 mA 5.2 mA 0.4 VA 250 mW 110 VAC 7.1 mA 7.5 mA --- 0.8 VA --- 230 VAC 7.3 mA 7.9 mA --- 1.7 VA --- *1) Rated currents are measured at 23 degrees Celsius (ambient) Contact Ratings Number of poles 1 pole Load Resistive load Inductive load (cos = 1) (cos = 0.4, L/R = 7 ms) Rated load 6 A at 250 VAC 2.5 A at 250 VAC 6 A at 30 VDC 2 A at 30 VDC Rated carry current 6 A Max. switching voltage 400 VAC, 125 VDC Max. switching current 6 A Max. switching power 1,500 VA 500 VA 180 W 60 W Failure rate (reference value) 10mA at 5VDC (P level) -6 Note: P level: = 0.1 x 10 /operation 60 Characteristics Item 1 pole Contact resistance 100 m max. Operate (set) time 20 ms max. Release time 40 ms max. Max. operating frequency Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts* 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.50 mm single amplitude (1.0 mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.50 mm single amplitude (1.0 mm double amplitude) 2 Shock resistance Destruction: 1,000 m/s 2 2 Malfunction: 200 m/s when energized 100 m/s when not energized Endurance Mechanical: 5,000,000 operations min. Electrical : 100,000 Typical NO 70,000 operations min. NC 50,000 operations min. Ambient temperature Operating: 40 C to 55 C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 35 g Overvoltage category III Pollution degree 2 Contact material AgSnIn Creepage distance 7.0 mm Clearance distance 5.5 mm Note: Values in the above table are the initial values. 2 Slim Relay G2RV