Solid State Relays (600 VAC Models)
G3NA-6
New Models Available at 600 VAC Load
Voltage Line with 10 A, 25 A and 50 A
Output Current
Load voltage range: 180 to 660 VAC
Lower input current: 7 mA max at 24 VDC
All models are same dimensions as G3NA series.
Built-in varistor effectively absorbs external surges.
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Certified by UL, CSA. RoHS Compliant.
Ordering Information
List of Models
Isolation Zero cross Indicator Applicable output load Rated input voltage Model
function (See note 1.)
Photocoupler Yes Yes 10 A at 400 to 600 VAC 5 to 24 VDC G3NA-610B DC5-24
100 to 240 VAC G3NA-610B AC100-240
25 A at 400 to 600 VAC 5 to 24 VDC G3NA-625B DC5-24
100 to 240 VAC G3NA-625B AC100-240
50 A at 400 to 600 VAC 5 to 24 VDC G3NA-650B DC5-24
100 to 240 VAC G3NA-650B AC100-240
Note: 1. The applicable output load depends on the ambient temperature. Refer to Load Current vs. Ambient Temperature in Engineering Data.
2. Loss time increases under 400 VAC. (Refer to Precautions for Correct Use.) Confirm operation with the actual load.
Accessories (Order Separately)
One-touch Mounting Plates
Model
R99-12 FOR G3NA
Heat Sinks
Slim Models Enabling DIN-track Mounting Low-cost Models
Model Applicable maximum load current
Model Applicable maximum load current
Y92B-A100 20 A
Y92B-N50 10 A
Y92B-A150N 40 A
Y92B-N100 20 A
Y92B-A250 40 A
Y92B-N150 40 A
Y92B-P250N 50 A
Solid State Relays (600 VAC Models) G3NA-6 485Specifications
Ratings
Input (at an Ambient Temperature of 25C)
Model Rated voltage Operating voltage Impedance Voltage level
(See note 1.)
Must operate voltage Must release voltage
G3NA-6@@B 5 to 24 VDC 4 to 32 VDC 7 mA max. 4 VDC max. 1 VDC min.
100 to 240 VAC 75 to 264 VAC 72 k20% 75 VAC max. 20 VAC min.
Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 240 VAC,
the input impedance is measured at 240 VAC).
2. Refer to Temperature Characteristics (for Must Operate Voltage and Must Release Voltage) in Engineering Data for further details.
Output
Model Applicable load
Rated load voltage Load voltage range Load current (See note 1.) Inrush current
With heat sink Without heat sink
(See note 2.)
G3NA-610B 400 to 600 VAC 360 to 660 VAC 0.5 to 10 A (at 40C) 0.5 to 4 A (at 40C) 150 A (60 Hz, 1 cycle)
G3NA-625B 0.5 to 25 A (at 40C) 0.5 to 4 A (at 40C) 220 A (60 Hz, 1 cycle)
G3NA-650B 0.5 to 50 A (at 40C) 0.5 to 6 A (at 40C) 440 A (60 Hz, 1 cycle)
Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data.
2. When an OMRON Heat Sink (refer to Options) or a heat sink of the specified size is used.
Characteristics
Item G3NA-610B G3NA-625B G3NA-650B
Operate time 1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
Release time 1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
Output ON voltage drop 1.8 V (RMS) max.
Leakage current 10 mA max. (at 400 VAC)
20 mA max. (at 600 VAC)
Insulation resistance 100 M min. (at 500 VDC)
Dielectric strength 4,000 VAC, 50/60 Hz for 1 min
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
2
Shock resistance
Destruction: 1,000 m/s
Ambient temperature Operating:30C to 80C (with no icing or condensation)
Storage: 30C to 100C (with no icing or condensation)
Ambient humidity Operating: 45% to 85%
Weight Approx. 120 g
486 Solid State Relays (600 VAC Models) G3NA-6