Solid State Relays (Single-phase) G3PB CSM G3PB DS E 2 1 Compact, Slim-profile SSR with Heat Sink, Offering Heater Control for 480-VAC Rated Loads Compact design achieved by optimizing heat sink shape. DIN track mounting possible in addition to screw mounting. Conforms to CE Marking, EN (VDE approval), UL, CSA, and VDE standards. (UL pending for 480 V series) Refer to Safety Precautions for All Solid State Relays. Model Number Structure Model Number Legend G3PB- - - 23 4 5 6 7 1 1. Basic Model Name 4. Terminal Type G3PB: Solid State Relay B: Screw terminals 2. Rated Load Power Supply Voltage 5. Number of Elements 2: 240 VAC Blank: Single-phase models 5: 480 VAC 6. Construction 3. Applicable Load Current Blank: DIN track mounting and built-in heat sink 15: 15 A 7. Certification 25: 25 A VD: Certified by CSA and VDE 35: 35 A 45: 45 A Ordering Information List of Models Isolation method Zero cross Operation Rated input Applicable load Model number function indicator voltage (See note.) Phototriac coupler Yes Yes (yellow) 12 to 24 VDC 15 A, 100 to 240 VAC G3PB-215B-VD DC12-24 25 A, 100 to 240 VAC G3PB-225B-VD DC12-24 35 A, 100 to 240 VAC G3PB-235B-VD DC12-24 45 A, 100 to 240 VAC G3PB-245B-VD DC12-24 15 A, 200 to 480 VAC G3PB-515B-VD DC12-24 25 A, 200 to 480 VAC G3PB-525B-VD DC12-24 35 A, 200 to 480 VAC G3PB-535B-VD DC12-24 45 A, 200 to 480 VAC G3PB-545B-VD DC12-24 Note: The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data. Accessories (Order Separately) Mounting Track 50 cm (1) x 7.3 mm (t) PFP-50N 1 m (1) x 7.3 mm (t) PFP-100N 1 m (1) x 16 mm (t) PFP-100N2 1G3PB Specifications Ratings (at an Ambient Temperature of 25C) Input Item Common Rated voltage 12 to 24 VDC Operating voltage range 9.6 to 30 VDC Rated input current 7 mA max. Must operate voltage 9.6 VDC max. Must release voltage 1 VDC min. Output Item G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- 215B-VD 225B-VD 235B-VD 245B-VD 515B-VD 525B-VD 535B-VD 545B-VD Rated load voltage 100 to 240 VAC (50/60 Hz) 200 to 480 VAC (50/60 Hz) Load voltage range 75 to 264 VAC (50/60 Hz) 180 to 528 VAC (50/60 Hz) Applicable load cur- 0.1 to 15 A 0.1 to 25 A 0.5 to 35 A 0.5 to 45 A 0.1 to 15 A 0.1 to 25 A 0.5 to 35 A 0.5 to 45 A rent (See note.) (at 40C) (at 40C) (at 25C) (at 25C) (at 40C) (at 40C) (at 25C) (at 25C) Inrush current resis- 150 A (60 Hz, 220 A (60 Hz, 440 A (60 Hz, 1 cycle) 150 A (60 Hz, 220 A (60 Hz, 440 A (60 Hz, 1 cycle) tance (peak value) 1 cycle) 1 cycle) 1 cycle) 1 cycle) 2 2 2 2 2 2 2 Permissible I t 121 A s 260 A s 1,260 A s 128 A s 1,350 A s 6,600 A s (half 60-Hz wave) Applicable load (with 3 kW 5 kW 7 kW 9 kW 6 kW max. 10 kW max. 14 kW max. 18 kW max. Class-1 AC resistive (at 200 VAC) (at 200 VAC) (at 200 VAC) (at 200 VAC) (at 400 VAC) (at 400 VAC) (at 400 VAC) (at 400 VAC) load) Note: The applicable load current varies depending on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data. Characteristics Item G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- 215B-VD 225B-VD 235B-VD 245B-VD 515B-VD 525B-VD 535B-VD 545B-VD Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. 1.8 V (RMS) max. Leakage current 10 mA max. (at 200 VAC) 20 mA max. (at 480 VAC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude (Mounted to DIN track) 2 Shock resistance Destruction: 294 m/s (DIN track mounting) Ambient temperature Operating: 30C to 80C (with no icing or condensation) Storage: 30C to 100C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Certified standards UL508 CSA22.2 No. 14 CSA22.2 No. 14 EN60947-4-3 EN60947-4-3 EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Weight Approx. 240 g Approx. 400 g Approx. 240 g Approx. 400 g 2