Single-phase Solid State Relays for Heaters G3PE Slim Profile Industrial SSR with Heatsink ideal for heater applications. Snubber circuit provides excellent short-term surge absorption. 15A and 25A models have slim 22.5mm width. Zero cross or fast turn on models. DIN track or panel mounting possible. LED indicator standard on all single phase models. UL, CSA and TV approved. RoHS compliant. Refer to Safety Precautions Ordering Information List of Models Number of Isolation Operation Rated input Zero cross Applicable load * Model phases method indicator voltage function 15 A, 100 to 240 VAC G3PE-215B DC12-24 25 A, 100 to 240 VAC G3PE-225B DC12-24 Yes 35 A, 100 to 240 VAC G3PE-235B DC12-24 45 A, 100 to 240 VAC G3PE-245B DC12-24 Phototriac Single-phase Yes (yellow) 12 to 24 VDC coupler 15 A, 100 to 240 VAC G3PE-215BL DC12-24 25 A, 100 to 240 VAC G3PE-225BL DC12-24 No 35 A, 100 to 240 VAC G3PE-235BL DC12-24 45 A, 100 to 240 VAC G3PE-245BL DC12-24 * The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in the Engineering Data section. Single-phase Solid State Relays for Heaters G3PE 445Specifications Ratings Input (at an Ambient Temperature of 25C) Voltage level Item Rated voltage Operating voltage range Rated input current Model Must operate voltage Must release voltage G3PE- B 12 to 24 VDC 9.6 to 30 VDC 7 mA max. 9.6 VDC max. 1.0 VDC max. G3PE- BL 15 mA max. Output Model G3PE-215B(L) G3PE-225B(L) G3PE-235B(L) G3PE-245B(L) Item Rated load voltage 100 to 240 VAC (50/60 Hz) Load voltage range 75 to 264 VAC (50/60 Hz) Applicable load current * 0.1 to 15 A 0.1 to 25 A 0.5 to 35 A 0.5 to 45 A (at 40C) (at 40C) (at 25C) (at 25C) Inrush current 150 A 220 A 440 A (60 Hz, 1 cycle) (60 Hz, 1 cycle) (60 Hz, 1 cycle) 2 2 2 2 Permissible I t 121A s 260A s 1,260A s (reference value) Applicable load 3 kW 5 kW 7 kW 9 kW (resistive load) (at 200 VAC) (at 200 VAC) (at 200 VAC) (at 200 VAC) * The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature Characteristics Model G3PE-215B G3PE-225B G3PE-235B G3PE-245B G3PE-215BL G3PE-225BL G3PE-235BL G3PE-245BL Item Operate time 1/2 of load power source cycle + 1 ms max. 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current 10 mA max. (at 200 VAC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 55 to10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) (Mounted to DIN track) 2 Shock resistance Destruction: 294 m/s (Mounted to DIN track) Ambient storage temperature 30 to 100C (with no icing or condensation) Ambient operating 30 to 80C (with no icing or condensation) temperature Ambient operating humidity 45% to 85% Weight Approx. 240 g Approx. 400 g Approx. 240 g Approx. 400 g 446 Single-phase Solid State Relays for Heaters G3PE