Solid State Contactors for Heaters G3PE-Three-phase CSM G3PE-Three-phase DS E 4 1 Compact, Slim-profile SSRs with Heat Sinks. Solid State Contactors for Three-phase Heaters Reduced Installation Work with DIN Track Mounting. RoHS compliant. Surge pass protection improved surge dielectric strength for output currents. (OMRON testing) Slim design with 3-phase output and built-in heat sinks. DIN Track mounting types and screw mounting types are available. All DIN Track mounting types mount to DIN Track (applicable DIN Track: TR35-15Fe (IEC 60715)). Conforms to UL, CSA, and EN standards (TV certification). Refer to Safety Precautions for All G3PE Models. Ordering Information List of Models Models with Built-in Heat Sinks Number of Insulation Operation Rated input Zero cross Number of *1 Type Applicable load Model phases method indicator voltage function poles 3 G3PE-215B-3N DC12-24 15 A, 100 to 240 VAC 2 G3PE-215B-2N DC12-24 3 G3PE-225B-3N DC12-24 25 A, 100 to 240 VAC 2 G3PE-225B-2N DC12-24 3 G3PE-235B-3N DC12-24 35 A, 100 to 240 VAC 2 G3PE-235B-2N DC12-24 3 G3PE-245B-3N DC12-24 45 A, 100 to 240 VAC 2 G3PE-245B-2N DC12-24 DIN track mounting *2 3 G3PE-515B-3N DC12-24 15 A, 200 to 480 VAC 2 G3PE-515B-2N DC12-24 3 G3PE-525B-3N DC12-24 25 A, 200 to 480 VAC 2 G3PE-525B-2N DC12-24 3 G3PE-535B-3N DC12-24 35 A, 200 to 480 VAC 2 G3PE-535B-2N DC12-24 3 G3PE-545B-3N DC12-24 45 A, 200 to 480 VAC 2 G3PE-545B-2N DC12-24 Phototriac Three-phase Yes (yellow) 12 to 24 VDC Yes coupler 3 G3PE-215B-3 DC12-24 15 A, 100 to 240 VAC 2 G3PE-215B-2 DC12-24 *3 3 G3PE-225B-3 DC12-24 25 A, 100 to 240 VAC 2 G3PE-225B-2 DC12-24 3 G3PE-235B-3 DC12-24 35 A, 100 to 240 VAC 2 G3PE-235B-2 DC12-24 3 G3PE-245B-3 DC12-24 45 A, 100 to 240 VAC 2 G3PE-245B-2 DC12-24 Screw mounting 3 G3PE-515B-3 DC12-24 15 A, 200 to 480 VAC 2 G3PE-515B-2 DC12-24 *3 3 G3PE-525B-3 DC12-24 25 A, 200 to 480 VAC 2 G3PE-525B-2 DC12-24 3 G3PE-535B-3 DC12-24 35 A, 200 to 480 VAC 2 G3PE-535B-2 DC12-24 3 G3PE-545B-3 DC12-24 45 A, 200 to 480 VAC 2 G3PE-545B-2 DC12-24 *1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5. *2. The applicable DIN Track is the TR35-15Fe (IEC 60715). For details, refer to the mounting information in the Safety Precautions for All G3PE Models. *3. DIN Track or Screw mounting. 1G3PE-Three-phase Models with Externally Attached Heat Sinks Number of Insulation Operation Rated input Zero cross Number Type Applicable load * Model phases method indicator voltage function of poles 3 G3PE-215B-3H DC12-24 15 A, 100 to 240 VAC 2 G3PE-215B-2H DC12-24 3 G3PE-225B-3H DC12-24 25 A, 100 to 240 VAC 2 G3PE-225B-2H DC12-24 3 G3PE-235B-3H DC12-24 35 A, 100 to 240 VAC 2 G3PE-235B-2H DC12-24 3 G3PE-245B-3H DC12-24 45 A, 100 to 240 VAC Externally 2 G3PE-245B-2H DC12-24 Phototriac Three-phase Yes (yellow) 12 to 24 VDC Yes attached heat coupler 3 G3PE-515B-3H DC12-24 sinks 15 A, 200 to 480 VAC 2 G3PE-515B-2H DC12-24 3 G3PE-525B-3H DC12-24 25 A, 200 to 480 VAC 2 G3PE-525B-2H DC12-24 3 G3PE-535B-3H DC12-24 35 A, 200 to 480 VAC 2 G3PE-535B-2H DC12-24 3 G3PE-545B-3H DC12-24 45 A, 200 to 480 VAC 2 G3PE-545B-2H DC12-24 * The rated load current depends on the heat sink or radiator that is mounted. It also depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature. Accessories (Order Separately) Heat Sink Heat resistance Rth (s-a) (C/W) Model 1.67 Y92B-P50 1.01 Y92B-P100 0.63 Y92B-P150 0.43 Y92B-P200 0.36 Y92B-P250 2