New Product Solid State Relays for Heaters G3PJ Single-phase SSR for low heat *1 generation enables carrying 25 A even for close mounting of three SSRs to contribute to downsizing of control panels. Models available with push-in input terminals. *2 SCCR of 10kA (UL 508). Surge pass protection improved surge dielectric strength for output currents. (OMRON testing) Both push-in and screw terminal input terminals available. Mount to DIN Track or with screws. For the recent information on models that have been certified Conforms to cULus and EN standards (TV certification). for safety standards, refer to your OMRON website. RoHS compliant. *1. G3PJ- 25B(-PU) *2. G3PJ-5 B(-PU) Refer to Safety Precautions on page 5. Model Number Structure Model Number Legend G3PJ - B - DC12-24 Basic Model Name 12 3 Rated input voltage 1. Rated Load Voltage 2. Rated Load Current for Three Close-mounted SSRs 3. Input Terminal Form 2: 24 to 240 VAC 15: 15 A Blank: Screw terminals 5: 100 to 480 VAC 25: 25 A PU: Push-in terminals Ordering Information Rated load current (ambient temperature of 40C) * Input Output Insulation Operation Rated input Zero cross Rated load Model terminal terminal method indicator voltage function voltage Close mounting Separate (Three SSRs) mounting 15 A 18 A G3PJ-215B DC12-24 24 to 240 VAC 25 A 27 A G3PJ-225B DC12-24 Screw terminals 15 A 23 A G3PJ-515B DC12-24 100 to 480 VAC 25 A 27 A G3PJ-525B DC12-24 Screw Phototriac Yes (orange) 12 to 24 VDC Yes terminals coupler 15 A 18 A G3PJ-215B-PU DC12-24 Push-In 24 to 240 VAC 25 A 27 A G3PJ-225B-PU DC12-24 Plus terminal 15 A 23 A G3PJ-515B-PU DC12-24 blocks 100 to 480 VAC 25 A 27 A G3PJ-525B-PU DC12-24 * The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 3. 1G3PJ Specifications Ratings Input (at an Ambient Temperature of 25C) Item Operating voltage Must operate Must release Rated voltage Current Model range voltage voltage G3PJ-2 B(-PU)/ 12 to 24 VDC 9.6 to 30 VDC 7 mA max. 9.6 VDC max. 1.0 VDC min. G3PJ-5 B(-PU) Output Item Load voltage 2 Rated load voltage Load current Inrush current resistance I t Model range Close mounting *: 0.1 to 15 A, 2 G3PJ-215B(-PU) 150 A (60 Hz, 1 cycle) 260A s Separate mounting: 0.1 to 18 A 24 to 240 VAC 19 to 264 VAC 50/60 Hz 50/60 Hz Close mounting *: 0.1 to 25 A, 2 G3PJ-225B(-PU) 220 A (60 Hz, 1 cycle) 1,260A s Separate mounting: 0.1 to 27 A Close mounting *: 0.1 to 15 A, 2 G3PJ-515B(-PU) 150 A (60 Hz, 1 cycle) 1,350A s Separate mounting: 0.1 to 23 A 100 to 480 VAC 75 to 528 VAC 50/60 Hz 50/60 Hz Close mounting *: 0.1 to 25 A, 2 G3PJ-525B(-PU) 220 A (60 Hz, 1 cycle) 6,600A s Separate mounting: 0.1 to 27 A * For close mounting of three SSRs. Characteristics Model G3PJ-2 B(-PU) G3PJ-5 B(-PU) Item Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. 1.8 V (RMS) max. Leakage current 10 mA max. (at 240 VAC) 20 mA max. (at 480 VAC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC 50/60 Hz for 1 min 4,000 VAC 50/60 Hz for 1 min Vibration resistance 10 to 55 to10 Hz, 0.35 mm single amplitude (0.7 mm double amplitude) (Mounted to DIN track) 2 Shock resistance Destruction: 300 m/s (Mounted to DIN track) Ambient storage -30 to 100C (with no icing or condensation) temperature Ambient operating -30 to 80C (with no icing or condensation) temperature Ambient operating humidity 45% to 85% Weight Approx. 240 g SCCR (UL508) 5 kA 10 kA Applicable Standards cULus and TV (EN 60947-4-3) Pollution category 2 RoHS compliant 2