G3VM-61BR/ER MOS FET Relays New Analog-switching MOS FET Relays Featuring a High Capacity of 2.5 A. Switches minute analog signals. Low ON-resistance of 0.1 max. Continuous load current of 2.5 A. RoHS compliant Note: The actual product is marked differently from the image shown here. Application Examples Terminal Arrangement/Internal Connections Test & Measurement equipment 64 Security equipment OMRON logo Model name Pin 1 mark 932 LOT.NO. 132 Note: The actual product is marked differently from the image shown here. List of Models Minimum package quantity Load voltage Package type Contact form Terminals Model (peak value) * Number per tube Number per tape and reel PCB Terminals G3VM-61BR 50 - 1a DIP6 60 V G3VM-61ER (SPST-NO) Surface-mounting Terminals G3VM-61ER(TR) -1,500 * The AC peak and DC value are given for the load voltage. Absolute Maximum Ratings (Ta = 25 C) Item Symbol Rating Unit Measurement conditions LED forward current IF 30 mA LED forward current reduction rate IF/C 0.3 mA/C Ta 25C LED reverse voltage VR 5 V Connection temperature TJ 125 C Load voltage (AC peak/DC) VOFF 60 V Continuous load current (AC peak/DC) IO 2500 mA ON current reduction rate IO/C 22 mA/C Ta 40C Connection temperature TJ 125 C Dielectric strength between I /O (See note 1.) VI-O 2500 Vrms AC for 1 min Note: 1. The dielectric strength between the input and Ambient operating temperature Ta 20 to +85 C With no icing or condensation output was checked by applying voltage Ambient storage temperature Tstg 40 to +125 C With no icing or condensation between all pins as a group on the LED side and Soldering temperature -260 C 10 s all pins as a group on the light-receiving side. Electrical Characteristics (Ta = 25 C) Item Symbol Minimum Typical Maximum Unit Measurement conditions LED forward voltage VF 1.18 1.33 1.48 V IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times Reverse current IR -- 10 A VR = 5 V IF 1 6 RL Capacity between terminals CT - 70 - pF V = 0, f = 1 MHz VDD VOUT Trigger LED forward current IFT -1.0 3 mA IO = 1 A 2 4 Maximum resistance with output ON -0.065 0.1 IF = 10 mA, IO = 2 A, t = 10 ms Current leakage when the relay is open ILEAK - 1.0 10 nA VOFF = 60 V Capacity between terminals COFF - 400 600 pF V = 0, f = 1 MHz IF Capacity between I/O terminals CI-O - 0.8 - pF f = 1 MHz, VS = 0 V Insulation resistance between I/O terminals RI-O 1000 - - M VI-O = 500 VDC, ROH 60% 90% VOUT Turn-ON time tON -1.0 1.5 ms IF = 10 mA, RL = 200 , 10% VDD = 20 V(See note 2.) tON tOFF Turn-OFF time tOFF -0.2 0.4 ms 1 Output Input Output InputG3VM-61BR/ER MOS FET Relays Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) VDD - - 48 V Operating LED forward current IF 10 - 20 mA Continuous load current (AC peak/DC) IO - - 2500 mA Ambient operating temperature Ta 25 - 60 C Engineering Data LED forward current vs. Ambient Continuous load current vs. Ambient LED forward current vs. LED forward temperature temperature voltage IF - Ta IO - Ta IF - VF 50 4 100 50 Ta = 25C 30 40 3 10 30 5 2 3 20 1 1 0.5 10 0.3 0.1 0 0 -20 0 20 40 60 80 100 120 -20 0 20 40 60 80 100 120 0.6 0.8 1 1.2 1.4 1.6 1.8 Ambient temperature Ta (C) Ambient temperature Ta (C) LED forward voltage VF (V) Continuous load current vs. On-state On-state resistance vs. Ambient Trigger LED forward current vs. voltage temperature Ambient temperature IO - VON RON - Ta IFT - Ta 3 200 5 IO = 2A Ta = 25C IO = 2A IF = 10mA IF = 10mA 2 4 150 1 3 0 100 2 -1 50 1 -2 0 -3 0 -150 -100 -50 0 50 100 150 -20 0 20 40 60 80 100 -20 0 20 40 60 80 100 On-state voltage VON (mV) Ambient temperature Ta (C) Ambient temperature Ta (C) Turn ON, Turn OFF time vs. LED Turn ON, Turn OFF time vs. Ambient Current leakage vs. Ambient forward current temperature temperature ILEAK - Ta tON, tOFF - IF tON, tOFF - Ta 30000 30000 1000 Ta = 25C VDD = 20V VOFF = 60V VDD = 20V, RL= 200 RL= 200 , IF = 5mA 10000 10000 3000 3000 t 100 ON 1000 1000 t ON t OFF 300 300 10 t OFF 100 100 30 30 1 0 10 20 30 -20 0 20 40 60 80 100 -20 0 20 40 60 80 100 LED forward current IF (mA) Ambient temperature Ta (C) Ambient temperature Ta (C) Safety Precautions Refer toCommon Precaution for all G3VM models. 2 Turn ON, Turn OFF time tON, tOFF (s) Continuous load current IO (A) LED forward current IF (mA) Turn ON, Turn OFF time tON, tOFF (s) On-state resistance RON (m ) Continuous load current IO (A) Current leakage ILEAK (nA) Trigger LED forward current IFT (mA) LED forward current IF (mA)