MOS FET Relays G3VM-61VY Special SOP4-pin package with Dielectric strength AC 3.75 kV Trigger LED forward current of 2 mA (maximum) facilitates power saving designs and prolonged battery life. Continuous load current of 70 mA. RoHS compliant Refer to Common Precautions. Note: The actual product is marked differently from the image shown here. Application Examples Broadband systems Security systems Industrial equipment Battery powered equipment Measurement devices Amusement machines List of Models Package Contact form Terminals Load voltage (peak value) Model Number per Number per (See the note.) stick tape Special SOP4 SPST-NO Surface-mounting 60 V G3VM-61VY 150 --- terminals G3VM-61VY(TR) --- 3,000 Note: The AC peak and DC value are given for the load voltage. Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-61VY 4.40.25 0.2 3.6 0.2 2.5 0.15 Note: The actual product is marked differ- 0.1 0.4 0.10.1 0.5min Weight: 0.1 g ently from the image shown here. 7.00.4 2.540.25 Terminal Arrangement/Internal Connections (Top View) G3VM-61VY 43 43 OMRON logo Model name LOT No. Pin 1 mark Note: The actual product is marked differently 12 12 from the image shown here. Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-61VY 6 to 6.3 1.2 0.8 2.54G3VM-61VY G3VM-61VY Absolute Maximum Ratings (T = 25C) a Item Symbol Rating Unit Measurement Conditions Note: 1. The dielectric strength between the Input LED forward current I 50 mA F input and output was checked by ap- Repetitive peak LED forward current I 1 A 100 s pulses, 100 pps FP plying voltage between all pins as a group on the LED side and all pins LED forward current reduction rate I /C 0.5 mA/CT 25C F a as a group on the light-receiving LED reverse voltage V 5V side. R Connection temperature T 125 C j Output Load voltage (AC peak/DC) V 60 V OFF Continuous load current (AC peak/DC) I 70 mA O ON current reduction rate I /C 0.7 mA/CT 25C O a Connection temperature T 125 C j Dielectric strength between input and V 3,750 V AC for 1 min I-O rms output (See note 1.) Operating temperature T 40 to +85 C With no icing or condensation a Storage temperature T 55 to +125 C With no icing or condensation stg Soldering temperature (10 s) --- 260 C10 s Electrical Characteristics (T = 25C) a Item Symbol Mini- Typical Maxi- Unit Measurement mum mum conditions Note: 2. Turn-ON and Turn-OFF Input LED forward voltage V 1.0 1.15 1.3 V I = 10 mA F F Times Reverse current I --- --- 10 AV = 5 V R R IF 1 4 RL VDD Capacity between terminals C --- 30 --- pF V = 0, f = 1 MHz T VOUT 2 3 Trigger LED forward current I --- 0.6 2 mA I = 70 mA FT O Output Maximum resistance with output ON R --- 25 50 I = 3 mA, ON F I = 70 mA O Current leakage when the relay is I --- 1 1000 nA V = 60 V LEAK OFF IF open Capacity between I/O terminals C --- 0.4 --- pF f = 1 MHz, Vs = 0 V I-O Insulation resistance R 1,000 --- --- M V = 500 VDC, 90% I-O I-O VOUT 10% R 60% oH t ON t OFF Turn-ON time t --- 1 5 ms I = 3 mA, R = 200 , ON F L V = 10 V (See note 2.) DD Turn-OFF time t --- 0.5 5 ms OFF Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) V --- --- 48 V DD Operating LED forward current I --- 3 25 mA F Continuous load current (AC peak/DC) I --- --- 60 mA O Operating temperature T 20 --- 65 C a Engineering Data Safety Precautions Load Current vs. Ambient Temperature Refer to Common Precautions for all G3VM models. G3VM-61VY 100 80 60 40 20 0 20 0 20 40 60 80 100 Ambient temperature (C) Load current (mA)