Omron 08 Cat 1-302 5/10/07 15:39 Page 144 PCB Power Relay G5RLText TPCB Power Relay G4Wext Impulse Withstand Voltage as High Dimensions Note: All units are in millimetres unless otherwise indicated. as 10 kV with 4kV Dielectric Strength: Ideal for Power Supply G5RL-1A-LN Switching Mounting Holes (Bottom View) Four, 1.30.1 dia. ROHS compliant. Creepage distance of 8 mm min. 7.50.1 29.0 max. Dielectric strength of 4,000 VAC min. 12.7max. (28.8) (12.5) SPST-NO types conform to TV-8 rating. (2.3) 3.50.1 200.1 DPST-NO types conform to TV-5 rating. 15.7 max. (15.5) Terminal Arrangement/ International 2.54mm terminal pitch. 3.5 Internal Connections (Bottom View) 3 1 0.43 1 0.5 0.5 0.33 * Indicates average 3.5 7.5 5 4 dimensions. 20 Ordering Information G5RL-1A-E-LN Contacts SPST-NO DPST-NO Mounting Holes Mounting style Terminals (Bottom View) Six, 1.30.1 dia. holes General purpose PCB (straight) G4W-1112P-US-TV8 G4W-2212P-US-TV5 29.0 max. 7.50.1 12.7 max. Note: When ordering, add the rated coil voltage to the model number. (28.8) (12.5) Example: G4W-1112P-US-TV8 12 VDC Rated coil voltage (2.3) 50.1 200.1 15.7 max. Terminal Arrangement/ (15.5) Model Number Legend Internal Connections 3.5 (Bottom View) - - -- G4W - VDC 1 3 4 12 3 4 5 6 7 8 0.5 0.5 0.43 1 0.33 5 Indicates average 7.5 6 5 1. Contact Form 5. Approved Standards 8 20 dimensions. 11: SPST-NO US: UL, CSA certified 22: DPST-NO 6. TV Ratings 2. Contact Type TV5: TV-5 1: Single Button TV8: TV-8 3. Enclosure Ratings 7. Special Function 2: Unsealed None: General purpose Z: Full-wave rectifier 4. Terminals P: Straight PCB 8. Rated Coil Voltage 12, 24, 100 VDC Mounting When mounting a G5RL-LN Relay (Silent Relay) on a PCB, use a diode for surge absorption for the coil. Disclaimer: All technical performance data applies to the product as such specific conditions of individual applications are not considered. Always check the suitability of the product for your intended purpose. OMRON does not assume any responsibility or liability for noncompliance herein, and we recommend prior technical clarification for applications where requirements, loading, or ambient conditions differ from ALL DIMENSIONS SHOWN ARE IN MILLIMETRES. To convert millimetres into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. CAT. No. K132-E2-01-X 144 145 Power RelaysOmron 08 Cat 1-302 5/10/07 15:39 Page 146 PCB Power Relay G4WText TPCB Power Relay G4Wext Characteristics Specifications Contact resistance 30 m max. Coil Ratings Single-side Stable Type Operate time 20 ms max. (mean value: approx. 13 ms) Release time 5 ms max. (mean value: approx. 2.5 ms) Rated voltage 12 VDC 24 VDC 100 VDC Bounce time Operate: approx. 3 ms Rated current 66.7 mA 33.3 mA 8 mA Max. Operating Frequency Mechanical: 18,000 operations/hr Coil resistance 180 720 12,500 Electrical: 1,800 operations/hr (under rated load) Coil inductance Armature OFF 0.93 3.7 61.8 Insulation resistance 100 M max. (at 500 VDC) (H) (ref. value) Armature ON 1.65 6.4 106 Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts Must operate voltage 80% max. of rated voltage 2,000 VAC, 50/60 Hz for 1 min between contacts of different polarities (DPST-NO) 1,500 VAC, 50/60 Hz for 1 min between contacts of same polarity Must release voltage 10% min. of rated voltage Insulation Creepage (Typ) 8.0 mm Max. voltage 130% of rated voltage (at 23C) Distance Clearance (Typ) 8.0 mm Power consumption Approx. 800 mW Tracking Resistance (CTI) 175 V Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 15%. Impulse withstand voltage 10,000 V (1.2 x 50 s) between coil and contacts 2. Operating characteristics are measured at a coil temperature of 23C. Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude) Contact Ratings Malfunction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude) Item SPST-NO DPST-NO 2 Shock resistance Destruction: 1,000 m/s 2 Malfunction: 150 m/s Load Resistive load Inductive load Resistive load Inductive load (cos = 1) (cos = 0.4 L/R = 7 ms) (cos = 1) (cos = 0.4 L/R = 7 ms) Endurance Mechanical: 5,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr) Rated load 15A at 250 VAC 10A at 250 VAC 10A at 250 VAC 7.5A at 250 VAC 15A at 24 VDC 7.5A at 24 VDC 10A at 24 VDC 5A at 24 VDC Ambient temperature Operating: -25C to 55C (with no icing) Contact material AgSnIn Ambient humidity Operating: 5% to 85% RH Rated carry current 15A 10A Weight Approx. 29 g Max. switching voltage 250 VAC, 125 VDC Max. switching current 15A 10A Max. switching power 3,750 VA, 375 W 2,500 VA, 255 W 2,500 VA, 240 W 1,850 VA, 120 W Failure rate (reference value) 100 mA at 5 VDC -6 Note: P level: 60 = 0.1 x 10 /operation 146 147 Power Relays