Initiated 9-3-08 CONVERTING FROM G5B-1 to G5NB-E and G5B-1-E to G5Q (Footprint only has partial compatibility so customer has to redesign PCB) Specification G5B-1 G5NB-E G5B-1-E G5Q Factory Load Rating 3A 125VAC 5A 125VAC 8A 125VAC 10A 125VAC (NO) (resistive) 3A 30VDC 3A 30VDC 8A 30VDC 5A 30VDC (NO) Max. Switching Power 750VA, 90W 1250VA, 90W 2000VA, 240W 1250VA, 150W (NO) Min. Permissible Load (ref.) 5VDC, 10mA 5VDC, 10mA 5VDC, 100mA 5VDC, 10mA UL Load Rating 3A 250VAC gen. 3A 250VAC res. 8A 250VAC res. 10A 120VAC res. (resistive or general rating) 30K Cycles 85C 100K Cycles 6K Cycles 85C 10K Cycles E150 120VAC 70C 2A 125VAC 70C C300, 100K Cycles,E 65C 100K Cycles 100K Cyclesstandard typ 85C UL Pilot Duty Rating NA UL Horsepower Rating 1/8HP 125VAC 1/10HP 277VAC*** 1/8HP 125VAC**** 1/4HP 250VAC 70C 30K ops Impulse Withstand Voltage* 10kV 10kV 10kV 8kV Dielectric Strength** 2000VAC 4000VAC 2000VAC 4000VAC Nominal Power 360mW 200mW 360mW 200mW (NO) Size in mm (l x w x h) max. 22.4 x 11.9 x 14.4 20.5 x 7.2 x 15.3 22.4 x 11.9 x 14.4 20.3 x 10.3 x 15.8 E-Life Res. AC rated load 200K (30cpm) 200K (30cpm) 100K (20cpm) 50K (15cpm) E-Life Res. DC rated load 200K (30cpm) 200K (30cpm) 100K (20cpm) 100K (30cpm) Standard DC Coil Voltages 5, 12, 24 5, 12, 24 5, 12, 24 5, 12, 24 Coil Class (standard) NA NA NA Class F Operate Time (max.) 10ms 10ms 10ms 10ms Release Time (max.) 10ms 10ms 10ms 5ms Approvals (standard type) UL, CSA, TUV UL, CSA, VDE UL, CSA, TUV UL, CSA, VDE Factory Max Operating Temp 70C 70C 70C 105C Pick-up Voltage (max.) 70% of coil voltage 75% of coil voltage 75% of coil voltage 75% of coil voltage Drop-out Voltage (min.) 5% of coil voltage 10% of coil voltage 5% of coil voltage 5% of coil voltage Enclosure Rating Flux-tight Flux-tight or Sealed Flux-tight Flux-tight or Sealed G5Q Footprint *(1.2 x 50us) between coil and contacts **for 1 minute 50-60Hz between coil and contacts ***30K Cycles 70C ****10K Cycles 70C G5NB-E Footprint G5B-G5B-1-E Footprint