Omron A5 Catalogue 2006 1-294 14/10/05 9:38 am Page 100 TPCB Power Relay G5CAext Flat Relays that Switch 10-A/15-A Loads with New Quick-connect Terminals ROHS compliant. Ideal for switching power in household appliances or for outputs from industrial devices. Sub-miniature dimensions: 22 x 16 x 11 mm (L x W x H). High-sensitivity models available with low power consumption (150 mW). UL and CSA approved. Fully sealed models and quick-connect terminal models available ( 187 load contact terminals). Ordering Information Contact form Enclosure ratings General purpose High-sensitivity High-capacity Quick-connect terminals SPST-NO Flux protection G5CA-1A G5CA-1AH G5CA-1AE G5CA-1AE-TP-E Fully sealed G5CA-1A4 G5CA-1A4H Note: 1. When ordering, add the rated coil voltage to the model number. Example: G5C-1 12 VDC Rated coil voltage 2. High-capacity models with a Fully sealed structure are not available. 3. Standard or high-sensitivity models with quick-connect terminals are not available. Model Number Legend G5CA-1A VDC 1 2 3 4 5 6 1. Number of Poles 4. Special functions Standard Specifications 1A: 1 pole (SPST-NO) None: Standard Contact configuration: SPST-NO E: High capacity Enclosure ratings: Flux protection Terminal form: PCB terminal 2. 2. Enclosure Ratings None: Flux protection 5. Coil Consumption 4: Fully sealed None: Standard H: High sensitivity 3. 3. Terminal Form None: PCB Terminal 6. 6. Rated coil voltage TP: Quick-connect terminal ( 187) 5, 12, 24 VDC ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. 100Omron A5 Catalogue 2006 1-294 14/10/05 9:38 am Page 101 TPCB Power Relay G5CAext Coil Ratings Item Standard, high-capacity, High-sensitivity or quick-connect terminals 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC Rated current 40 mA 16.7 mA 8.3 mA 30 mA 12.5 mA 6.25 mA Coil resistance 125 720 2,880 167 960 3,840 Must operate voltage 75% max. of rated voltage 80% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 150% (standard)/130% (high-capacity, 150% (at 23C) quick-connect terminals) of rated voltage (at 23C) Power consumption Approx. 200 mW Approx. 150 mW Contact Ratings Item Standard High-sensitivity High-capacity, or quick-connect terminals Resistive load Inductive load Resistive load Inductive load Resistive load Inductive load (cos = 1) (cos = 0.4, (cos = 1) (cos = 0.4, (cos = 1) (cos = 0.4, L/R = 7 ms) L/R = 7 ms) L/R = 7 ms) Contact MaterialAgSnIn AgSnIn AgSnIn Rated load 10 A at 250 VAC 3 A at 250 VAC 10 A at 250 VAC 3 A at 250 VAC 15 A at 110 VAC 5 A at 110 VAC 10 A at 30 VDC 3 A at 30 VDC 10 A at 30 VDC 3 A at 30 VDC 10 A at 30 VDC 3 A at 30 VDC Rated carry current 10 A 10 A 15 A Max. switching 250 VAC, 125 VDC 250 VAC, 125 VDC 250 VAC, 125 VDC voltage Max. switching 10 A 10 A 15 A current Max. switching 2,500 VA, 300 W 750 VA, 90 W 2,500 VA, 300 W 750 VA, 90 W 2,500 VA, 300 W 750 VA, 90 W Characteristics Contact resistance 30 m max. (Quick-connect terminals type: 100 m max.) Operate time 10 ms max. (High-sensitivity type: 15 ms max.) Release time 10 ms max. Insulation resistance 1,000 M min. Dielectric strength 2,500 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity Insulation Creepage (Typ) 3.5 mm Distance Clearance (Typ) 2.8 mm Tracking Resistance (CTI) 250 V Impulse withstand voltage 4,500 V (1.2 x 50 s) between coil and contacts Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) 2 Shock resistance Destruction: 1,000 m/s 2 Malfunction: 200 m/s Endurance Mechanical: 20,000,000 operations min. at 18,000 operations/hr Electrical: 300,000 operations min. (100,000 operations min. for Fully sealed Type) at 1,200 operations/hr under rated load of 10 A at 250 VAC 100,000 operations min. under load of 15 A at 110 VAC for high-capacity models 100,000 operations min. at 1,200 operations/hr under rated load of 10 A at 30 VDC Ambient temperature Operating: -25C to 70C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 8 g (for TP model: Approx. 9.6 g) Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. 101 Power Relays