PCB Relay G5C(E) Flat Relays that Switch 10-A/15-A Loads with New Quick-connect Terminals Ideal for switching power in household appliances or for outputs from industrial devices. Subminiature dimensions: 22 16 11 mm (L W H). High-sensitivity models available with low power consumption (150 mW). UL and CSA approved. Fully sealed models and quick-connect terminal models available ( 187 load contact terminals). RCE Ordering Information Contact form Enclosure ratings General purpose High-sensitivity High-capacity Quick-connect terminals SPST-NO Flux protection G5C-1 G5C-1-H G5CE-1 G5CE-1-TP Fully sealed G5C-14 G5C-14-H --- --- Note: 1. When ordering, add the rated coil voltage to the model number. Example: G5C-1 12 VDC Rated coil voltage 2. High-capacity models with a Fully sealed structure are not available. 3. Standard or high-sensitivity models with quick-connect terminals are not available. 4. VDE-approved models are available. Contact your OMRON representative for more details. 5. Models with PTI250 are also available. Contact your OMRON representative for more details. Model Number Legend G5C - - VDC 1 2 34 5 1. Relay 2. Number of Poles 4. Classification 1: 1 pole (SPST-NO) None: Standard H: High-sensitivity E: High-capacity 3. Enclosure Ratings TP: Quick-connect terminals ( 187) None: Flux protection 5. Rated Coil Voltage 4: Fully sealed 3, 5, 6, 12, 24, 48 VDC 128G5C(E) G5C(E) Specifications Coil Ratings Item Standard, high-capacity, or quick-connect High-sensitivity terminals 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC Rated current 40 mA 16.7 mA 8.3 mA 30 mA 12.5 mA 6.25 mA Coil resistance 125 W 720 W 2,880 W 167 W 960 W 3,840 W Must operate voltage 75% max. of rated voltage 80% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 150% (standard)/130% (high-capacity, quick-con- 150% (at 23 C) nect terminals) of rated voltage (at 23 C) Power consumption Approx. 200 mW Approx. 150 mW Contact Ratings Item Standard High-sensitivity High-capacity, or quick-connect terminals Resistive load Inductive load Resistive load Inductive load Resistive load Inductive load (cosf = 1) (cosf = 0.4, (cosf = 1) (cosf = 0.4, (cosf = 1) (cos f = 0.4, L/R = 7 ms) L/R = 7 ms) L/R = 7 ms) Rated load 10 A at 250 VAC 3 A at 250 VAC 10 A at 250 VAC 3 A at 250 VAC 15 A at 110 VAC 5 A at 110 VAC 10 A at 30 VDC 3 A at 30 VDC 10 A at 30 VDC 3 A at 30 VDC 10 A at 30 VDC 3 A at 30 VDC Rated carry current 10 A 10 A 15 A Max. switching 250 VAC 250 VAC 250 VAC voltage Max. switching 10 A 10 A 15 A current Max. switching 2,500 VA, 300 W 750 VA, 90 W 2,500 VA, 300 W 750 VA, 90 W 2,500 VA, 300 W 750 VA, 90 W power Characteristics Contact resistance 30 m W max. (Quick-connect terminals type: 100 mW max.) Operate time 10 ms max. (High-sensitivity type: 15 ms max.) Release time 10 ms max. Insulation resistance 1,000 MW min. Dielectric strength 2,500 VAC, 50/60 Hz for 1 min between contacts of same polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 4,500 V (1.2 x 50 s) between coil and contacts Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) 2 Shock resistance Destruction: 1,000 m/s 2 Malfunction: 200 m/s Endurance Mechanical: 20,000,000 operations min. at 18,000 operations/hr Electrical: 300,000 operations min. (100,000 operations min. for Fully sealed Type) at 1,200 operations/hr under rated load of 10 A at 250 VAC 100,000 operations min. under load of 15 A at 110 VAC for high-capacity models 100,000 operations min. at 1,200 operations/hr under rated load of 10 A at 30 VDC Ambient temperature Operating: -25C to 70C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 8 g (for TP model: Approx. 9.6 g) Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. Approved Standards UL508 (file No. E41515)/CSA C22.2 No.14 (file No. LR31928) Coil rating Contact rating 3 to 100 VDC 15 A, 125 VAC 10 A, 250 VAC 10 A, 30 VDC (resistive load only) 129