G5LE PCB Power Relay Cubic, Single-pole 10A Power Relay Ideal for a wide variety of applications such as home appliances, OA equipments, vending machines, etc. Ambient Operating Temperature 85C UL class-B coil insulation for standard model. UL, CSA, EN standards approved and conforms to Electrical Appliance and Material Safety Law (300 V max.). RoHS Compliant Model Number Legend Application Examples G5LE- - - Home appliances OA equipments 12 3 4 5 1. Number of Poles 4. Insulation System Vending machines 1: 1-pole None: Class B (Class F for -E versions) CF: Class F (UL and CSA only) G 2. Contact Form 5 5. Approved Standards None: SPDT (1c) L None: Standard A: SPST-NO (1a) E E: High capacity type 3. Enclosure rating None: Flux protection 4: Fully sealed Ordering Information Enclosure rating Flux protection Fully sealed Minimun Terminal Shape Classification Contact form Model Rated coil voltage Model Rated coil voltage packing unit 5 VDC 5 VDC G5LE-1 12 VDC G5LE-14 12 VDC 24 VDC 24 VDC SPDT (1c) 5 VDC 5 VDC G5LE-1-CF 12 VDC G5LE-14-CF 12 VDC 24 VDC 24 VDC Standard 5 VDC 5 VDC G5LE-1A 12 VDC G5LE-1A4 12 VDC 24 VDC 24 VDC PCB terminals SPST-NO (1a) 100 pcs/tray 5 VDC 5 VDC G5LE-1A-CF 12 VDC G5LE-1A4-CF 12 VDC 24 VDC 24 VDC 5 VDC SPDT (1c) G5LE-1-E 12 VDC --- 24 VDC High capacity 5 VDC SPST-NO (1a) G5LE-1A-E 12 VDC --- 24 VDC Note. When ordering, add the rated coil voltage to the model number. Example: G5LE-1 DC5 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Ratings Classification Standard type High capacity type Item Load Resistive load Inductive load (cos=0.4) Resistive load Contact type Single Contact material Ag-alloy (Cd free) 16 A at 250 VAC (NO) Rated load 10 A at 120 VAC, 8 A at 30 VDC 5 A at 120 VAC, 4 A at 30 VDC 12 A at 250 VAC (NC) Rated carry current 10 A 16A (NO)/12A (NC) Max. switching voltage 250 VAC, 125 VDC (30 VDC when UL/CSA standard is applied) 250 VAC Max. switching current 10 A 5 A 16A (NO)/12A (NC) 1G5LE PCB Power Relay Characteristics Item Classification Standard type High capacity type Contact resistance *1 100 m max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance *2 100 M min. Between coil and 2,000 VAC, 50/60 Hz for 1 min contacts Dielectric strength Between contacts of the 750 VAC, 50/60 Hz for 1 min same polarity Impulse withstand between coil and contacts 4,500 V (1.250 s) voltage Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Vibration resistance Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 2 Destruction 1,000 m/s Shock resistance 2 Malfunction 100 m/s Mechanical 10,000,000 operations min. (at 18,000 operations/hr) 50,000 operations min. (NO) Durability 100,000 operations min. Electrical 30,000 operations min. (NC) (at 1,800 operations/hr) (at 1,800 operations/hr) Failure rate (P level) (reference value) *3 100 mA at 5 VDC Ambient operating temperature -25C to 85C (with no icing or condensation) Ambient operating humidity 35% to 85% Weight Approx. 12 g Note. The data given above are initial values *1. Measurement conditions: 5 VDC, 1 A, voltage drop method. *2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. G *3. This value was measured at a switching frequency of 120 operations/min. 5 L E 2