G5PZ PCB Power Relay Compact 20 A Power Relay 10.5 mm (W) slim size and 1 pole 16 A/20 A switching capability High sensitivity of 530 mW coil consumption and further saving energy with holding voltage 50% Min. 6.4 mm of insulation distance and 10 kV impulse withstand voltage (between coil and contacts) IEC60664-1 Reinforced insulation conformed RoHS Compliant Model Number Legend G5PZ- - 12 3 4 1. Number of Poles 2. Contact Form 3. Enclosure rating 4. Classification 1 : 1-pole A : SPST-NO (1a) None : Flux protection None : Standard G E : High-capacity 5 P Z Application Examples Air conditioners OA equipments Home appliances Industrial machinery Ordering Information Classification Contact form Enclosure rating Model Rated coil voltage Minimum packing unit Standard G5PZ-1A 5 VDC SPST-NO (1a) Flux protection 12 VDC 100 pcs. / Tray High-capacity G5PZ-1A-E 24 VDC Note 1. When ordering, add the rated coil voltage to the model number. Example: G5PZ-1A DC12 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Ratings Coil Item Rated current (mA) Coil resistance () Must-operate voltage (V) Must-release voltage (V) Max. voltage (V) Power consumption (mW) Rated voltage % of rated voltage 5 VDC 106 47 140% 12 VDC 44.1 272 75% max. 10% min. Approx. 530 (at 23C) 24 VDC 22.1 1087 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The Max. voltage is the maximum voltage that can be applied to the relay coil. Contacts Classification Standard High-capacity Model G5PZ-1A G5PZ-1A-E Item Load Resistive load Contact type Single Contact material Ag-alloy (Cd free) Rated load 16 A at 250 VAC 20 A at 250 VAC Rated carry current 16 A 20 A Max. switching voltage 250 VAC Max. switching current 16 A 20 A 1G5PZ PCB Power Relay Characteristics Actual Load Life (Reference Values) 1. 250 VAC Inverter load (Standard) Classification Standard High-capacity Inrush: 240 A (0-P, Rise Time 3 ms or more), Current 16 A, Cut Item Model G5PZ-1A G5PZ-1A-E off current 0 A Contact resistance *1 100 m max. 50,000 operations min. (at 23C) Operate time 15 ms max. 2. 250 VAC Inverter load (High-capacity) Release time 5 ms max. Inrush: 240 A (0-P, Rise Time 3 ms or more), Current 20 A, Insulation resistance *2 1,000 M min. Cut off current 0 A Between coil 4,000 VAC 50/60 Hz 1 min and contacts 50,000 operations min. (at 23C) Dielectric Between strength contacts of the 1,000 VAC 50/60 Hz 1 min same polarity Impulse Between coil withstand 10 kV (1.2 x 50 s) and contacts voltage 10 to 55 to 10 Hz, 0.75 mm single amplitude Destruction (1.5 mm double amplitude) Vibration resistance 10 to 55 to 10 Hz, 0.75 mm single amplitude Malfunction (1.5 mm double amplitude) 2 Destruction 1,000 m/s Shock resistance 2 Malfunction 200 m/s Mechanical 2,000,000 operations min. Durability Electrical 100,000 operations 50,000 operations G (resistive load) at 250 VAC, 16 A at 250 VAC, 20 A 5 P Failure rate (P level) 5 VDC 100 mA Z (reference value) *3 Ambient operating -40 to 70C temperature (with no icing or condensation) Ambient operating humidity 5 to 85% Weight Approx. 10.5 g Note. Values in the above table are the initial values at 23C. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method *2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. *3. This value was measured at a switching frequency of 120 operations/min. 2