R PCB Relay G5Q Compact, High Isolation Relay H Compact single pole relay with high isolation between coil and contacts H Up to 10 A switching on the NO contacts H Ensures a withstand impulse voltage of 8,000 V between the coil and contacts H Low coil power consumption H UL class F coil insulation H UL, CSA, and VDE approvals H Ideal for appliance and HVAC controls Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G5Q-14-DC12) Classification Enclosure rating Part number SSiinnggllee ccoonnttaacctt,, ccllaassss FF ccooiill SSPPSSTT--NNOO Vented G5Q-1A Sealed G5Q-1A4 SSPPDDTT Vented G5Q-1 Sealed G5Q-14 Specifications J COIL RATINGS Rated voltage (V) Rated coil Coil Pick-up Drop-out Maximum Power current (mA) resistance voltage voltage voltage consumption (W) (mW) SSPPDDTT DC 5 80 63 7755%% ooff mmaaxx.. 55%% ooff mmaaxx.. 119900%% 2233CC 440000 DC 12 33.3 360 DC 24 16.7 1440 SSPPSSTT--NNOO 220000 DC 5 40 125 DC 12 16.7 720 DC 24 8.3 2880 Note: Rated current and coil resistance are measured at 23C with a tolerance of 10%.G5Q G5Q J CONTACT RATINGS Load SPDT SPST-NO Rated load (resistive) 10 A 125 VAC (NO) 10 A 125 VAC 3 A 250 VAC (NO) 3 A 250 VAC 5 A 30 VDC (NO) 5 A 30 VDC 3 A 125 VAC (NC) 3 A 30 VDC (NC) Contact material Ag Alloy Rated carry current 10 A (NO)/3 A (NC) Max. switching voltage 277 VAC, 30 VDC Max. switching current AC: 10 A (NO)/3 A (NC) DC: 5 A (NC)/3 A (NC) Max. switching capacity 1250 VA, 150 W (NO) 375 VA, 90 W (NC) --6 Min. permissible load 10 mA at 5 VDC (P level: l60=0.1 x 10 operation) J CHARACTERISTICS Contact resistance (See Note 2.) 100 mW max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance (See Note 3.) 1,000 MW min. Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts 1000 VAC, 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 8 kV (1.2 x 50 ms) between coil and contacts VViibbrraattiioonn rreessiissttaannccee DDeessttrruuccttiioonn:: 1100 ttoo 5555 HHzz,, 11..55--mmmm ddoouubbllee aammpplliittuuddee ffoorr 22 hhoouurrss MMaallffuunnccttiioonn:: 1100 ttoo 5555 HHzz,, 11..55--mmmm ddoouubbllee aammpplliittuuddee ffoorr 55 mmiinnuutteess 22 SShhoocckk rreessiissttaannccee DDeessttrruuccttiioonn:: 11,,000000 mm//ss ((aapppprrooxx.. 110000GG)) 22 MMaallffuunnccttiioonn:: 110000 mm//ss ((aapppprrooxxiimmaatteellyy 1100GG)) LLiiffee eexxppeeccttaannccyy ((SSeeee NNoottee 44..)) Mechanical 10,000,000 operations (18,000 operations per hour) Electrical 200,000 operations: 3 A (NO)/3 A (NC) at 125-VAC resistive load 100,000 operations: 3 A (NO)/3 A (NC) at 250 VAC 5 A (NO)/3 A (NC) at 30-VDC resistive load 50,000 operations: 10 A (NO) at 125-VAC (900 operations per hour) Switching 1,800 operations per hour frequency Ambient temperature Operating & --40C to 105C (--40F to 221F) with no freezing or condensation storage Ambient humidity Operating & 5% to 85% storage Note: 1. The data shown above are initial values. 2. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. 3. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC. 4. The electrical life data items shown are possible at 23C. 2